| #!/usr/bin/python |
| |
| r""" |
| Contains PLDM-related constants. |
| """ |
| |
| PLDM_SUPPORTED_TYPES = ['base', 'platform', 'bios', 'fru', 'oem-ibm'] |
| |
| # PLDM types. |
| PLDM_TYPE_BASE = {'VALUE': '00', 'STRING': 'base'} |
| PLDM_TYPE_PLATFORM = {'VALUE': '02', 'STRING': 'platform'} |
| PLDM_TYPE_BIOS = {'VALUE': '03', 'STRING': 'bios'} |
| PLDM_TYPE_FRU = {'VALUE': '04', 'STRING': 'fru'} |
| PLDM_TYPE_OEM = {'VALUE': '63', 'STRING': 'oem-ibm'} |
| |
| VERSION_BASE = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'} |
| VERSION_PLATFORM = {'VALUE': ['f1', 'f2', 'f0', '00'], 'STRING': '1.2.0'} |
| VERSION_BIOS = {'VALUE': ['f1', 'f1', 'f1', '00'], 'STRING': '1.0.0'} |
| VERSION_FRU = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'} |
| VERSION_OEM = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'} |
| |
| |
| PLDM_BASE_CMDS = ['2(GetTID)', '3(GetPLDMVersion)', '4(GetPLDMTypes)', '5(GetPLDMCommands)'] |
| PLDM_PLATFORM_CMDS = ['57(SetStateEffecterStates)', '81(GetPDR)'] |
| PLDM_BIOS_CMDS = ['1(GetBIOSTable)', '7(SetBIOSAttributeCurrentValue)', |
| '8(GetBIOSAttributeCurrentValueByHandle)', '12(GetDateTime)', |
| '13(SetDateTime)'] |
| PLDM_FRU_CMDS = ['1(GetFRURecordTableMetadata)', '2(GetFRURecordTable)'] |
| PLDM_OEM_CMDS = ['1(GetFileTable)', '4(ReadFile)', '5(WriteFile)', '6(ReadFileInToMemory)', |
| '7(WriteFileFromMemory)', '8(ReadFileByTypeIntoMemory)', |
| '9(WriteFileByTypeFromMemory)', '10(NewFileAvailable)', |
| '11(ReadFileByType)', '12(WriteFileByType)', '13(FileAck)', |
| '240(GetAlertStatus)'] |
| |
| # PLDM command format. |
| |
| ''' |
| e.g. : GetPLDMVersion usage |
| |
| pldmtool base GetPLDMVersion -t <pldm_type> |
| |
| pldm supported types |
| |
| base->0,platform->2,bios->3,fru->4 |
| |
| ''' |
| CMD_GETPLDMVERSION = 'base GetPLDMVersion -t %s' |
| |
| ''' |
| e.g. : PLDM raw command usage |
| |
| pldmtool raw -d 0x80 0x00 0x03 0x00 0x00 0x00 0x00 0x01 0x00 |
| |
| pldm raw -d 0x<header> 0x<pldm_type> 0x<pldm_cmd_type> 0x<payload_data> |
| ''' |
| |
| CMD_PLDMTOOL_RAW = 'raw -d 0x80' + '0x%s' + ' ' + '0x%s' |
| |
| |
| # PLDM command payload data. |
| |
| PAYLOAD_GetPLDMVersion = \ |
| ' 0x00 0x00 0x00 0x00 0x%s 0x%s' # %(TransferOperationFlag, PLDMType) |
| |
| |
| ''' |
| e.g. : SetDateTime usage |
| |
| pldmtool bios SetDateTime -d <YYYYMMDDHHMMSS> |
| |
| ''' |
| CMD_SETDATETIME = 'bios SetDateTime -d %s' |
| |
| |
| CMD_GETPDR = 'platform GetPDR -d %s' |
| |
| ''' |
| e.g. : SetStateEffecterStates usage |
| |
| pldmtool platform GetPDR -i <effter_handle> -c <count> -d <effecterID, effecterState> |
| |
| pldmtool platform SetStateEffecterStates -i 1 -c 1 -d 1 1 |
| ''' |
| |
| CMD_SETSTATEEFFECTERSTATES = 'platform SetStateEffecterStates -i %s -c %s -d %s' |
| |
| # GetPDR parsed response message for record handle. |
| # Dictionary value array holds the expected output for record handle 1, 2. |
| # |
| # Note : |
| # Record handle - 0 is default & has same behaviour as record handle 1 |
| # Only record handle 0, 1, 2 are supported as of now. |
| |
| RESPONSE_DICT_GETPDR_SETSTATEEFFECTER = { |
| 'responsecount': ['29', '30'], |
| 'pdrheaderversion': ['1'], |
| 'pdrtype': ['11'], |
| 'recordchangenumber': ['0'], |
| 'datalength': ['19', '20'], |
| 'pldmterminushandle': ['0'], |
| 'effecterid': ['1', '2', '3'], |
| 'entitytype': ['33', '45', '31'], |
| 'entityinstancenumber': ['0'], |
| 'containerid': ['0'], |
| 'effectersemanticid': ['0'], |
| 'effecterinit': ['0'], |
| 'effecterdescriptionpdr': ['false'], |
| 'compositeeffectercount': ['1'], |
| 'statesetid': ['196', '260', '129'], |
| 'possiblestatessize': ['1', '2'], |
| 'possiblestates': ['6', '0', '64']} |
| |
| RESPONSE_DICT_GETPDR_FRURECORDSETIDENTIFIER = { |
| 'responsecount': ['20'], |
| 'pdrheaderversion': ['1'], |
| 'pdrtype': ['20'], |
| 'recordchangenumber': ['0'], |
| 'datalength': ['10'], |
| 'pldmterminushandle': ['0', '2'], |
| 'entitytype': ['System Board', 'Chassis front panel board (control panel)', |
| 'Management Controller', '208(OEM)', 'Power converter', |
| 'System (logical)', 'System chassis (main enclosure)', |
| 'Chassis front panel board (control panel)', |
| 'Processor Module', 'Memory Module'], |
| 'containerid': ['0', '1', '2', '3']} |
| |
| RESPONSE_DICT_GETPDR_PDRENTITYASSOCIATION = { |
| 'pdrheaderversion': ['1'], |
| 'pdrtype': ['15'], |
| 'recordchangenumber': ['0'], |
| 'containerid': ['1', '2', '3'], |
| 'associationtype': ['Physical'], |
| 'containerentitytype': ['System Board', 'System (logical)', |
| 'System chassis (main enclosure)'] |
| } |
| |
| PLDM_PDR_TYPES = { |
| 'PLDM_STATE_EFFECTER_PDR': '11', |
| 'PLDM_PDR_FRU_RECORD_SET': '20', |
| 'PLDM_PDR_ENTITY_ASSOCIATION': '15'} |
| |
| RESPONSE_LIST_GETBIOSTABLE_STRTABLE = [ |
| 'Allowed', 'Disabled', 'Enabled', 'IPv4DHCP', 'IPv4Static', 'Not Allowed', |
| 'Perm', 'Temp', 'pvm-fw-boot-side', 'pvm-inband-code-update', 'pvm-os-boot-side', |
| 'pvm-pcie-error-inject', 'pvm-surveillance', 'pvm-system-name', 'vmi-hostname', |
| 'vmi-if-count', 'vmi-if0-ipv4-ipaddr', 'vmi-if0-ipv4-method', |
| 'vmi-if0-ipv4-prefix-length', 'vmi-if1-ipv4-ipaddr', 'vmi-if1-ipv4-method', |
| 'vmi-if1-ipv4-prefix-length', 'vmi-ipv4-gateway'] |