| *** Settings *** |
| Documentation Update firmware on a target BMC via Redifsh. |
| |
| # Test Parameters: |
| # IMAGE_FILE_PATH The path to the BMC image file. |
| # |
| # Firmware update states: |
| # Enabled Image is installed and either functional or active. |
| # Disabled Image installation failed or ready for activation. |
| # Updating Image installation currently in progress. |
| |
| Resource ../../lib/resource.robot |
| Resource ../../lib/bmc_redfish_resource.robot |
| Resource ../../lib/openbmc_ffdc.robot |
| Resource ../../lib/common_utils.robot |
| Resource ../../lib/code_update_utils.robot |
| Resource ../../lib/dump_utils.robot |
| Resource ../../lib/logging_utils.robot |
| Resource ../../lib/redfish_code_update_utils.robot |
| Resource ../../lib/utils.robot |
| Resource ../../lib/bmc_redfish_utils.robot |
| Resource ../../lib/external_intf/management_console_utils.robot |
| Resource ../../lib/bmc_network_utils.robot |
| Library ../../lib/gen_robot_valid.py |
| Library ../../lib/tftp_update_utils.py |
| Library ../../lib/gen_robot_keyword.py |
| |
| Suite Setup Suite Setup Execution |
| Suite Teardown Redfish.Logout |
| Test Setup Printn |
| Test Teardown FFDC On Test Case Fail |
| |
| Force Tags BMC_Code_Update |
| |
| *** Variables *** |
| |
| @{ADMIN} admin_user TestPwd123 |
| &{USERS} Administrator=${ADMIN} |
| ${LOOP_COUNT} ${2} |
| @{HOSTNAME} bmc_system01 bmc_system02 bmc_system03 bmc_system04 bmc_system05 |
| |
| *** Test Cases *** |
| |
| Redfish Code Update With ApplyTime OnReset |
| [Documentation] Update the firmware image with ApplyTime of OnReset. |
| [Tags] Redfish_Code_Update_With_ApplyTime_OnReset |
| [Template] Redfish Update Firmware |
| |
| # policy |
| OnReset |
| |
| |
| Redfish Code Update With ApplyTime Immediate |
| [Documentation] Update the firmware image with ApplyTime of Immediate. |
| [Tags] Redfish_Code_Update_With_ApplyTime_Immediate |
| [Template] Redfish Update Firmware |
| |
| # policy |
| Immediate |
| |
| |
| Redfish Code Update Same Firmware Multiple Times |
| [Documentation] Multiple times update the firmware image for update service. |
| [Tags] Redfish_Code_Update_Same_Firmware_Multiple_Times |
| |
| ${temp_update_loop_count}= Evaluate ${LOOP_COUNT} + 1 |
| |
| FOR ${count} IN RANGE 1 ${temp_update_loop_count} |
| Print Timen *************************************** |
| Print Timen * The Current Loop Count is ${count} of ${LOOP_COUNT} * |
| Print Timen *************************************** |
| |
| Redfish Update Firmware apply_time=OnReset |
| END |
| |
| |
| |
| Redfish Code Update With Multiple Firmware |
| [Documentation] Update the firmware image with ApplyTime of Immediate. |
| [Tags] Redfish_Code_Update_With_Multiple_Firmware |
| [Template] Redfish Multiple Upload Image And Check Progress State |
| |
| # policy image_file_path alternate_image_file_path |
| Immediate ${IMAGE_FILE_PATH} ${ALTERNATE_IMAGE_FILE_PATH} |
| |
| |
| Post BMC Reset Perform Redfish Code Update |
| [Documentation] Test to reset BMC at standby and then perform BMC firmware update and |
| ... ensure there is not error or dump logs post update. |
| [Tags] Post_BMC_Reset_Perform_Redfish_Code_Update |
| |
| Redfish Delete All BMC Dumps |
| Redfish Purge Event Log |
| |
| Redfish OBMC Reboot (off) |
| |
| Redfish Update Firmware apply_time=OnReset |
| |
| Event Log Should Not Exist |
| Redfish BMC Dump Should Not Exist |
| |
| Redfish Power Off |
| |
| |
| Post BMC Reset Perform Image Switched To Backup Multiple Times |
| [Documentation] Test to reset BMC at standby and then perform switch |
| ... to backup image multiple times. |
| ... Then ensure no event and dump logs exist. |
| [Tags] Post_BMC_Reset_Perform_Image_Switched_To_Backup_Multiple_Times |
| |
| Redfish Delete All BMC Dumps |
| Redfish Purge Event Log |
| |
| Redfish OBMC Reboot (off) |
| |
| ${temp_update_loop_count}= Evaluate ${LOOP_COUNT} + 1 |
| |
| FOR ${count} IN RANGE 1 ${temp_update_loop_count} |
| ${state}= Get Pre Reboot State |
| |
| # change to backup image and reset the BMC. |
| Switch Backup Firmware Image To Functional |
| |
| Wait For Reboot start_boot_seconds=${state['epoch_seconds']} |
| END |
| |
| Event Log Should Not Exist |
| Redfish BMC Dump Should Not Exist |
| |
| |
| Verify If The Modified Admin Credential Is Valid Post Image Switched To Backup |
| [Documentation] Verify updated admin credential remain same post switch to back up image. |
| [Tags] Verify_If_The_Modified_Admin_Credential_Is_Valid_Post_Image_Switched_To_Backup |
| [Setup] Create Users With Different Roles users=${USERS} force=${True} |
| [Teardown] Run Keywords Redfish.Login AND Delete BMC Users Via Redfish users=${USERS} |
| |
| ${post_code_update_actions}= Get Post Boot Action |
| ${state}= Get Pre Reboot State |
| Expire And Update New Password Via Redfish ${ADMIN[0]} ${ADMIN[1]} 0penBmc123 |
| |
| Redfish.Login |
| # change to backup image and reset the BMC. |
| Switch Backup Firmware Image To Functional |
| Wait For Reboot start_boot_seconds=${state['epoch_seconds']} |
| |
| # verify modified admin password on backup image. |
| Redfish.Login admin_user 0penBmc123 |
| Redfish.Logout |
| |
| |
| Verify If The Modified Admin Credential Is Valid Post Update |
| [Documentation] Verify updated admin credential remain same post code update image. |
| [Tags] Verify_If_The_Modified_Admin_Credential_Is_Valid_Post_Update |
| [Setup] Create Users With Different Roles users=${USERS} force=${True} |
| [Teardown] Run Keywords Redfish.Login AND Delete BMC Users Via Redfish users=${USERS} |
| |
| Expire And Update New Password Via Redfish ${ADMIN[0]} ${ADMIN[1]} 0penBmc123 |
| |
| Redfish.Login |
| # Flash latest firmware using redfish. |
| Redfish Update Firmware OnReset |
| |
| # verify modified admin credentails on latest image. |
| Redfish.Login admin_user 0penBmc123 |
| Redfish.Logout |
| |
| |
| Redfish Code Update With Different Interrupted Operation |
| [Documentation] Ensure firmware update is successful when different interrupted operation executed |
| ... i.e. change the hostname. |
| [Tags] Redfish_Code_Update_With_Different_Interrupted_Operation |
| [Template] Verify Redfish Code Update With Different Interrupted Operation |
| |
| # operation count |
| host_name 1 |
| kernel_panic 1 |
| |
| *** Keywords *** |
| |
| Suite Setup Execution |
| [Documentation] Do the suite setup. |
| |
| Valid File Path IMAGE_FILE_PATH |
| Redfish.Login |
| |
| Redfish Delete All BMC Dumps |
| Redfish Purge Event Log |
| |
| Redfish Power Off stack_mode=skip |
| |
| |
| Redfish Update Firmware |
| [Documentation] Update the BMC firmware via redfish interface. |
| [Arguments] ${apply_time} |
| |
| # Description of argument(s): |
| # policy ApplyTime allowed values (e.g. "OnReset", "Immediate"). |
| |
| ${post_code_update_actions}= Get Post Boot Action |
| ${state}= Get Pre Reboot State |
| Rprint Vars state |
| Set ApplyTime policy=${apply_Time} |
| |
| ${task_inv_dict}= Get Task State from File |
| |
| ${file_bin_data}= OperatingSystem.Get Binary File ${image_file_path} |
| |
| Log To Console Start uploading image to BMC. |
| Upload Image To BMC ${REDFISH_BASE_URI}UpdateService timeout=${600} data=${file_bin_data} |
| Log To Console Completed image upload to BMC. |
| |
| ${task_inv}= Check Task With Match TargetUri /redfish/v1/UpdateService |
| |
| Rprint Vars task_inv |
| |
| Wait Until Keyword Succeeds 5 min 10 sec |
| ... Verify Task Progress State ${task_inv} ${task_inv_dict['TaskCompleted']} |
| |
| Run Key ${post_code_update_actions['BMC image']['${apply_time}']} |
| Redfish.Login |
| Redfish Verify BMC Version ${IMAGE_FILE_PATH} |
| Verify Get ApplyTime ${apply_time} |
| |
| |
| Redfish Multiple Upload Image And Check Progress State |
| [Documentation] Update multiple BMC firmware via redfish interface and check status. |
| [Arguments] ${apply_time} ${IMAGE_FILE_PATH} ${ALTERNATE_IMAGE_FILE_PATH} |
| |
| # Description of argument(s): |
| # apply_time ApplyTime allowed values (e.g. "OnReset", "Immediate"). |
| # IMAGE_FILE_PATH The path to BMC image file. |
| # ALTERNATE_IMAGE_FILE_PATH The path to alternate BMC image file. |
| |
| ${post_code_update_actions}= Get Post Boot Action |
| Valid File Path ALTERNATE_IMAGE_FILE_PATH |
| ${state}= Get Pre Reboot State |
| Rprint Vars state |
| |
| Set ApplyTime policy=${apply_time} |
| Redfish Upload Image ${REDFISH_BASE_URI}UpdateService ${IMAGE_FILE_PATH} |
| |
| ${first_image_id}= Get Latest Image ID |
| Rprint Vars first_image_id |
| Sleep 5s |
| Redfish Upload Image ${REDFISH_BASE_URI}UpdateService ${ALTERNATE_IMAGE_FILE_PATH} |
| |
| ${second_image_id}= Get Latest Image ID |
| Rprint Vars second_image_id |
| |
| Check Image Update Progress State |
| ... match_state='Updating', 'Disabled' image_id=${second_image_id} |
| |
| Check Image Update Progress State |
| ... match_state='Updating' image_id=${first_image_id} |
| |
| Wait Until Keyword Succeeds 8 min 20 sec |
| ... Check Image Update Progress State |
| ... match_state='Enabled' image_id=${first_image_id} |
| Run Key ${post_code_update_actions['BMC image']['${apply_time}']} |
| Redfish.Login |
| Redfish Verify BMC Version ${IMAGE_FILE_PATH} |
| |
| |
| Run Configure BMC Hostname In Loop |
| [Documentation] Update hostname in loop. |
| [Arguments] ${count} |
| |
| # Description of argument(s): |
| # count Loop count. |
| |
| FOR ${index} IN RANGE ${count} |
| Configure Hostname hostname=${HOSTNAME}[${index}] status_code=[${HTTP_INTERNAL_SERVER_ERROR}] |
| END |
| |
| |
| Run Operation On BMC |
| [Documentation] Run operation on BMC. |
| [Arguments] ${operation} ${count} |
| |
| # Description of argument(s): |
| # operation If host_name then change hostname. |
| # count Loop count. |
| |
| Run Keyword If '${operation}' == 'host_name' Run Configure BMC Hostname In Loop count=${count} |
| Run Keyword If '${operation}' == 'kernel_panic' |
| ... Run Keywords Kernel Panic BMC Reset Operation AND |
| ... Is BMC Unpingable |
| |
| |
| Get Active Firmware Image |
| [Documentation] Return get active firmware image. |
| |
| ${active_image}= Redfish.Get Attribute /redfish/v1/Managers/bmc Links |
| Rprint Vars active_image |
| |
| [Return] ${active_image} |
| |
| |
| Verify Redfish Code Update With Different Interrupted Operation |
| [Documentation] Verify code update is successful when other operation |
| ... getting executed i.e. change the hostname. |
| [Arguments] ${operation} ${count} |
| |
| # Description of argument(s): |
| # operation host_name to change Hostname, kernel_panic to perform kernel panic. |
| # count Number of times loop will get executed. |
| |
| ${before_update_activeswimage}= Get Active Firmware Image |
| |
| ${post_code_update_actions}= Get Post Boot Action |
| |
| Set ApplyTime policy=OnReset |
| |
| ${task_inv_dict}= Get Task State from File |
| |
| ${file_bin_data}= OperatingSystem.Get Binary File ${image_file_path} |
| |
| Log To Console Start uploading image to BMC. |
| Upload Image To BMC ${REDFISH_BASE_URI}UpdateService timeout=${600} data=${file_bin_data} |
| Log To Console Completed image upload to BMC. |
| |
| ${task_inv}= Check Task With Match TargetUri /redfish/v1/UpdateService |
| Rprint Vars task_inv |
| |
| Wait Until Keyword Succeeds 1 min 10 sec |
| ... Verify Task Progress State ${task_inv} ${task_inv_dict['TaskStarting']} |
| |
| Run Operation On BMC ${operation} ${count} |
| |
| Run Keyword If '${operation}' == 'kernel_panic' |
| ... Wait Until Keyword Succeeds 10 min 10 sec Is BMC Standby |
| |
| Run Keyword If '${operation}' == 'host_name' |
| ... Run Keywords Wait Until Keyword Succeeds 5 min 10 sec |
| ... Verify Task Progress State ${task_inv} ${task_inv_dict['TaskCompleted']} AND |
| ... Run Key ${post_code_update_actions['BMC image']['OnReset']} AND |
| ... Redfish.Login AND |
| ... Redfish Verify BMC Version ${IMAGE_FILE_PATH} |
| |
| ${after_update_activeswimage}= Get Active Firmware Image |
| |
| ${status}= Run Keyword And Return Status Should Be Equal As Strings |
| ... ${before_update_activeswimage['ActiveSoftwareImage']['@odata.id']} |
| ... ${after_update_activeswimage['ActiveSoftwareImage']['@odata.id']} |
| |
| Run Keyword If '${operation}' == 'kernel_panic' |
| ... Should Be True ${status} |
| ... ELSE |
| ... Should Not Be True ${status} |
| |
| Verify Get ApplyTime OnReset |
| |