blob: 1c030b313d1b597e02deacd53472b3c6d20c16ab [file] [log] [blame]
#!/usr/bin/python
r"""
Contains PLDM-related constants.
"""
PLDM_SUPPORTED_TYPES = ['base', 'platform', 'bios']
# PLDM types.
PLDM_TYPE_BASE = {'VALUE': '00', 'STRING': 'base'}
PLDM_TYPE_PLATFORM = {'VALUE': '02', 'STRING': 'platform'}
PLDM_TYPE_BIOS = {'VALUE': '03', 'STRING': 'bios'}
PLDM_TYPE_FRU = {'VALUE': '04', 'STRING': 'fru'}
PLDM_TYPE_OEM = {'VALUE': '3F', 'STRING': 'oem'}
VERSION_BASE = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'}
VERSION_PLATFORM = {'VALUE': ['f1', 'f2', 'f0', '00'], 'STRING': '1.2.0'}
VERSION_BIOS = {'VALUE': ['f1', 'f1', 'f1', '00'], 'STRING': '1.0.0'}
VERSION_FRU = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'}
# PLDM base related variables.
PLDM_BASE_CMD = {
'GET_TID': '02',
'GET_PLDM_VERSION': '03',
'GET_PLDM_TYPES': '04',
'GET_PLDM_COMMANDS': '05'}
# Response lengths are inclusive of completion code.
GET_TID_RESP_BYTES = 2
GET_PLDM_VERSION_RESP_BYTES = 10
GET_PLDM_TYPES_RESP_BYTES = 9
GET_PLDM_COMMANDS_RESP_BYTES = 33
# PLDM bios related variables.
PLDM_BIOS_CMD = {
'GET_BIOS_TABLE': '01',
'SET_BIOS_ATTRIBUTE_CURRENT_VALUE': '07',
'GET_BIOS_ATTRIBUTE_CURRENT_VALUE_BY_HANDLE': '08',
'GET_DATE_TIME': '0c'}
PLDM_BIOS_TABLE_TYPES = {
'STRING_TABLE': '00',
'ATTRIBUTE_TABLE': '01',
'ATTRIBUTE_VAL_TABLE': '02'}
TRANSFER_OPERATION_FLAG = {
'GETNEXTPART': '00',
'GETFIRSTPART': '01'}
TRANSFER_RESP_FLAG = {
'PLDM_START': '01',
'PLDM_MIDDLE': '02',
'PLDM_END': '04',
'PLDM_START_AND_END': '05'}
# PLDM platform related variables.
PLDM_PLATFORM_CMD = {
'SET_STATE_EFFECTER_STATES': '39',
'GET_PDR': '51'}
PLDM_PDR_TYPES = {
'STATE_EFFECTER_PDR': '11'}
# PLDM OEM related variables.
PLDM_FILEIO_CMD = {
'GET_FILE_TABLE': '1',
'READ_FILE': '4',
'WRITE_FILE': '5',
'READ_FILE_INTO_MEMORY': '6',
'WRITE_FILE_FROM_MEMORY': '7'}
PLDM_FILEIO_COMPLETION_CODES = {
'INVALID_FILE_HANDLE': '80',
'DATA_OUT_OF_RANGE': '81',
'INVALID_READ_LENGTH': '82',
'INVALID_WRITE_LENGTH': '83',
'FILE_TABLE_UNAVAILABLE': '84',
'INVALID_FILE_TABLE_TYPE': '85'}
# PLDM FRU related variables.
PLDM_FRU_CMD = {
'PLDM_GET_FRU_RECORD_TABLE_METADATA': '01',
'PLDM_GET_FRU_RECORD_TABLE': '02'}
# PLDM command format.
'''
e.g. : GetPLDMVersion usage
pldmtool base GetPLDMVersion -t <pldm_type>
pldm supported types
base->0,platform->2,bios->3,fru->4
'''
CMD_GETPLDMVERSION = 'base GetPLDMVersion -t %s'
'''
e.g. : PLDM raw command usage
pldmtool raw -d 0x80 0x00 0x03 0x00 0x00 0x00 0x00 0x01 0x00
pldm raw -d 0x<header> 0x<pldm_type> 0x<pldm_cmd_type> 0x<payload_data>
'''
CMD_PLDMTOOL_RAW = 'raw -d 0x80' + '0x%s' + ' ' + '0x%s'
# PLDM command payload data.
PAYLOAD_GetPLDMVersion = \
' 0x00 0x00 0x00 0x00 0x%s 0x%s' # %(TransferOperationFlag, PLDMType)
'''
e.g. : SetDateTime usage
pldmtool bios SetDateTime -d <YYYYMMDDHHMMSS>
'''
CMD_SETDATETIME = 'bios SetDateTime -d %s'