blob: ebbbe78316113720e3d028d621d1fd1f39dccba1 [file] [log] [blame]
*** Settings ***
Documentation This example demonstrates executing commands on a remote machine
... and getting their output and the return code.
...
... Notice how connections are handled as part of the suite setup and
... teardown. This saves some time when executing several test cases.
Resource ../lib/rest_client.robot
Resource ../lib/ipmi_client.robot
Resource ../lib/openbmc_ffdc.robot
Library ../data/model.py
Suite setup Setup The Suite
Suite Teardown Close All Connections
Test Teardown Log FFDC
*** Variables ***
${model} = ${OPENBMC_MODEL}
*** Test Cases ***
Verify connection
Execute new Command echo "hello"
Response Should Be Equal "hello"
Execute ipmi BT capabilities command
[Tags] Execute_ipmi_BT_capabilities_command
Run IPMI command 0x06 0x36
response Should Be Equal " 01 40 40 0a 01"
Execute Set Sensor boot count
${uri} = Get System component BootCount
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x01 0x00 0x35 0x00 0x00 0x00 0x00 0x00 0x00
Read the Attribute ${uri} value
${val} = convert to integer 53
Response Should Be Equal ${val}
Set Sensor Boot progress
${uri} = Get System component BootProgress
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x04 0x00 0x00 0x00 0x00 0x14 0x00
Read the Attribute ${uri} value
Response Should Be Equal FW Progress, Baseboard Init
Set Sensor Boot progress Longest string
${uri} = Get System component BootProgress
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x04 0x00 0x00 0x00 0x00 0x0e 0x00
Read The Attribute ${uri} value
Response Should Be Equal FW Progress, Docking station attachment
BootProgress sensor FW Hang unspecified Error
${uri} = Get System component BootProgress
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x02 0x00 0x00 0x00 0x00 0x00 0x00
Read The Attribute ${uri} value
Response Should Be Equal FW Hang, Unspecified
BootProgress fw hang state
${uri} = Get System component BootProgress
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x01 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal POST Error, unknown
OperatingSystemStatus Sensor boot completed progress
${uri} = Get System component OperatingSystemStatus
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x01 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal Boot completed (00)
OperatingSystemStatus Sensor progress
${uri} = Get System component OperatingSystemStatus
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x04 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal PXE boot completed
OCC Active sensor on enabled
${uri} = Get System component OccStatus
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x02 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal Enabled
OCC Active sensor on disabled
${uri} = Get System component OccStatus
${x} = Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x01 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal Disabled
CPU Present
${uri} = Get System component cpu
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x80 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal True
CPU not Present
${uri} = Get System component cpu
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x00 0x00 0x80 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal False
CPU fault
${uri} = Get System component cpu
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0xff 0x00 0x01 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal True
CPU no fault
${uri} = Get System component cpu
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x00 0x00 0x00 0x01 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal False
core Present
${uri} = Get System component core11
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x80 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal True
core not Present
${uri} = Get System component core11
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x00 0x00 0x80 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal False
core fault
${uri} = Get System component core11
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0xff 0x00 0x01 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal True
core no fault
${uri} = Get System component core11
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x00 0x00 0x00 0x01 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal False
DIMM3 Present
${uri} = Get System component dimm3
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x40 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal True
DIMM3 not Present
${uri} = Get System component dimm3
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0xff 0x00 0x00 0x40 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal False
DIMM0 fault
${uri} = Get System component dimm0
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x10 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal True
DIMM0 no fault
${uri} = Get System component dimm0
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x00 0x00 0x10 0x00 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal False
Centaur0 Present
[Tags] Centaur0_Present
${uri} = Get System component membuf
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0xa9 0x00 0x40 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal True
Centaur0 not Present
[Tags] Centaur0_not_Present
${uri} = Get System component membuf
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x00 0x00 0x40 0x00 0x00 0x20 0x00
Read The Attribute ${uri} present
Response Should Be Equal False
Centaur0 fault
${uri} = Get System component membuf
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x10 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal True
Centaur0 no fault
${uri} = Get System component membuf
${x} = Get Inventory Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x00 0x00 0x10 0x00 0x00 0x20 0x00
Read The Attribute ${uri} fault
Response Should Be Equal False
System Present
[Tags] System_Present
${uri} = Get System component system
Read The Attribute ${uri} present
Response Should Be Equal True
System Fault
${uri} = Get System component system
Read The Attribute ${uri} fault
Response Should Be Equal False
Chassis Present
[Tags] Chassis_Present
${uri} = Get System component chassis
Read The Attribute /org/openbmc/inventory/system/chassis present
Response Should Be Equal True
Chassis Fault
${uri} = Get System component chassis
Read The Attribute /org/openbmc/inventory/system/chassis fault
Response Should Be Equal False
io_board Present
[Tags] io_board_Present
${uri} = Get System component io_board
Read The Attribute ${uri} present
Response Should Be Equal True
io_board Fault
[Tags] io_board_Fault
${uri} = Get System component io_board
Read The Attribute ${uri} fault
Response Should Be Equal False
*** Keywords ***
Setup The Suite
Open Connection And Log In
${resp} = Read Properties /org/openbmc/enumerate
Set Suite Variable ${SYSTEM_INFO} ${resp}
log Dictionary ${resp}
Get System component
[Arguments] ${type}
${list} = Get Dictionary Keys ${SYSTEM_INFO}
${resp} = Get Matches ${list} regexp=^.*[0-9a-z_].${type}[0-9]*$
${url} = Get From List ${resp} 0
[return] ${url}
Execute new Command
[arguments] ${args}
${output}= Execute Command ${args}
set test variable ${OUTPUT} "${output}"
response Should Be Equal
[arguments] ${args}
Should Be Equal ${OUTPUT} ${args}
Response Should Be Empty
Should Be Empty ${OUTPUT}
Read the Attribute
[arguments] ${uri} ${parm}
${output} = Read Attribute ${uri} ${parm}
set test variable ${OUTPUT} ${output}
Get Sensor Number
[arguments] ${name}
${x} = get sensor ${OPENBMC_MODEL} ${name}
[return] ${x}
Get Inventory Sensor Number
[arguments] ${name}
${x} = get inventory sensor ${OPENBMC_MODEL} ${name}
[return] ${x}