blob: fc68fb5a62e57e1f5716f2d562d52e0bb14948d2 [file] [log] [blame]
*** Settings ***
Documentation Module to test PLDM platform commands.
Library ../lib/pldm_utils.py
Variables ../data/pldm_variables.py
Resource ../lib/openbmc_ffdc.robot
Resource ../lib/bmc_redfish_resource.robot
Resource ../lib/boot_utils.robot
Test Setup Printn
Test Teardown FFDC On Test Case Fail
Suite Teardown Pldmtool Platform Suite Cleanup
Force Tags Pldm_Platform
*** Test Cases ***
Verify GetPDR
[Documentation] Verify GetPDR (Platform Descpritor Record) response message.
[Tags] Verify_GetPDR
${record_handle}= Set Variable ${1}
# Note: Record handle count is unknown and it is dynamic in nature.
# Assuming there are 100 record handle.
FOR ${i} IN RANGE 100
${next_record_handle}= Run Keyword Verify GetPDR For Record Handle ${record_handle}
Exit For Loop If ${next_record_handle} == 0
${record_handle}= Set Variable ${next_record_handle}
END
Verify SetStateEffecterStates
[Documentation] Verify set state effecter states response message.
[Tags] Verify_SetStateEffecterStates
[Template] Verify SetStateEffecterStates For Effecter States
# EffecterHandle Count EffecterStates (effecterID effecterState)
'1' '1' '1 1' # (effecterState -> 1 -> 'Boot Not Active')
'1' '1' '1 2' # (effecterState -> 2 -> 'Boot Completed')
'2' '1' '1 9' # (effecterState -> 9 -> 'System Power is in soft off mode')
'3' '1' '1 6' # (effecterState -> 6 -> 'Graceful Restart Requested')
*** Keywords ***
Verify GetPDR For Record Handle
[Documentation] Verify GetPDR (Platform Descpritor Record) for given input
... record handle and return next record handle.
[Arguments] ${record_handle}
# Description of argument(s):
# ${record_handle} Record handle.
# e.g. '1' is record handle 'Boot Progress' (196).
# '2' is record handle 'System Power State (260)'.
# '3' is record handle 'Software Termination Status (129)'.
# pldm_output:
# [responseCount]: 29
# [recordHandle]: 1
# [PDRHeaderVersion]: 1
# [PDRType]: 11
# [recordChangeNumber]: 0
# [dataLength]: 19
# [PLDMTerminusHandle]: 0
# [effecterID]: 1
# [entityType]: 33
# [entityInstanceNumber]: 0
# [containerID]: 0
# [effecterSemanticID]: 0
# [effecterInit]: 0
# [effecterDescriptionPDR]: false
# [compositeEffecterCount]: 1
# [stateSetID]: 196
# [possibleStatesSize]: 1
# [possibleStates]: 6
${pldm_cmd}= Evaluate $CMD_GETPDR % ${record_handle}
${pldm_output}= Pldmtool ${pldm_cmd}
Rprint Vars pldm_output
Run Keyword If '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_STATE_EFFECTER_PDR']}'
... Valid Dict pldm_output valid_values=${RESPONSE_DICT_GETPDR_SETSTATEEFFECTER}
... ELSE IF '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_PDR_FRU_RECORD_SET']}'
... Valid Dict pldm_output valid_values=${RESPONSE_DICT_GETPDR_FRURECORDSETIDENTIFIER}
... ELSE IF '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_PDR_ENTITY_ASSOCIATION']}'
... Log To Console "Found PDR Type - PLDM_ENTITY_ASSOCIATION_PDR"
... ELSE IF '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_STATE_SENSOR_PDR']}'
... Valid Dict pldm_output valid_values=${RESPONSE_DICT_GETPDR_STATESENSORPDR}
... ELSE IF '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_NUMERIC_EFFECTER_PDR']}'
... Valid Dict pldm_output valid_values=${RESPONSE_DICT_GETPDR_NUMERICEFFECTERPDR}
... ELSE IF '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_TERMINUS_LOCATOR_PDR']}'
... Valid Dict pldm_output valid_values=${RESPONSE_DICT_GETPDR_TERMINUSLOCATORPDR}
... ELSE IF '${pldm_output['PDRType']}' == '${PLDM_PDR_TYPES['PLDM_COMPACT_NUMERIC_SENSOR_PDR']}'
... Log To Console "Found PDR Type - PLDM_COMPACT_NUMERIC_SENSOR_PDR'
... ELSE Fail msg="Unknown PDR Type is received"
Should be equal as strings ${pldm_output['recordHandle']} ${record_handle}
RETURN ${pldm_output['nextRecordHandle']}
Verify SetStateEffecterStates For Effecter States
[Documentation] Verify set state effecter states for given input effecter states.
[Arguments] ${effecter_handle} ${count} ${effecter_states}
# Description of argument(s):
# ${effecter_handle} A handle that is used to identify and access the effecter (e.g. '1').
# e.g. '1' is effecter handle 'Boot Progress'.
# '2' is effecter handle 'System Power State'.
# ${count} The number of individual sets of effecter information (e.g. '1').
# ${effecter_states} (effecterID effecterState).
# e.g. '1 1'.
# Example output:
# {
# "Response": "SUCCESS"
# }
${pldm_cmd}= Evaluate $CMD_SETSTATEEFFECTERSTATES % (${effecter_handle}, ${count}, ${effecter_states})
${pldm_output}= Pldmtool ${pldm_cmd}
Rprint Vars pldm_output
Valid Value pldm_output['Response'] ['SUCCESS']
Pldmtool Platform Suite Cleanup
[Documentation] Reset BMC at suite cleanup.
Redfish.Login
Redfish OBMC Reboot (off)