blob: c1cf6ed333b7cea90d98b02456a3f1e98cabbc02 [file] [log] [blame]
#!/usr/bin/env python
r"""
Set the auto_boot policy according to the caller's wishes.
"""
import os
import sys
save_path_0 = sys.path[0]
del sys.path[0]
from gen_print import *
from gen_valid import *
from gen_arg import *
from gen_misc import *
from gen_cmd import *
from gen_plug_in_utils import *
from gen_call_robot import *
# Restore sys.path[0].
sys.path.insert(0, save_path_0)
# Set exit_on_error for gen_valid functions.
set_exit_on_error(True)
parser = argparse.ArgumentParser(
usage='%(prog)s [OPTIONS]',
description="%(prog)s will set the auto_boot policy according to the"
+ " user's wishes.",
formatter_class=argparse.RawTextHelpFormatter,
prefix_chars='-+')
# Populate stock_list with options we want.
stock_list = [("test_mode", get_plug_default("test_mode", 0)),
("quiet", get_plug_default("quiet", 0)),
("debug", get_plug_default("debug", 0))]
AUTO_REBOOT_DISABLE = "1"
def exit_function(signal_number=0,
frame=None):
r"""
Execute whenever the program ends normally or with the signals that we catch (i.e. TERM, INT).
"""
dprint_executing()
dprint_var(signal_number)
# Your cleanup code here.
qprint_pgm_footer()
def signal_handler(signal_number,
frame):
r"""
Handle signals. Without a function to catch a SIGTERM or SIGINT, our program would terminate immediately
with return code 143 and without calling our exit_function.
"""
# Our convention is to set up exit_function with atexit.register() so there is no need to explicitly
# call exit_function from here.
dprint_executing()
# Calling exit prevents us from returning to the code that was running when we received the signal.
exit(0)
def validate_parms():
r"""
Validate program parameters, etc. Return True or False (i.e. pass/fail) accordingly.
"""
get_plug_vars()
valid_value(AUTOBOOT_OPENBMC_HOST)
global AUTO_REBOOT_DISABLE
if pgm_name == "cp_cleanup":
AUTO_REBOOT_DISABLE = 0
else:
valid_value(AUTO_REBOOT_DISABLE, valid_values=["0", "1"])
AUTO_REBOOT_DISABLE = int(AUTO_REBOOT_DISABLE)
gen_post_validation(exit_function, signal_handler)
def main():
gen_get_options(parser, stock_list)
validate_parms()
qprint_pgm_header()
print_plug_in_header()
if pgm_name == "cp_setup" or pgm_name == "cp_cleanup":
exit_not_master()
init_robot_out_parms(get_plug_in_package_name() + "." + pgm_name + ".")
lib_file_path = init_robot_file_path("lib/utils.robot")
enable_auto_reboot = 1 - AUTO_REBOOT_DISABLE
print_var(enable_auto_reboot)
keyword_string = "Set Auto Reboot ${%i}" % enable_auto_reboot
cmd_buf = create_robot_cmd_string("extended/run_keyword.robot", OPENBMC_HOST, SSH_PORT, HTTPS_PORT,
REST_USERNAME, REST_PASSWORD, keyword_string, lib_file_path, quiet,
test_mode, debug, outputdir, output, log, report)
if not robot_cmd_fnc(cmd_buf):
print_error_report("Robot command execution failed.")
exit(1)
main()