| *** Settings *** |
| Documentation This program performs factory data reset, namely, |
| ... network, host and BMC factory reset on DHCP setup. |
| |
| Resource ../lib/rest_client.robot |
| Resource ../lib/utils.robot |
| Resource ../lib/connection_client.robot |
| Resource ../lib/boot_utils.robot |
| Resource ../lib/code_update_utils.robot |
| Resource ../lib/ipmi_client.robot |
| |
| *** Test Cases *** |
| |
| Initiate Factory Reset And Verify |
| [Documentation] Factory reset the system. |
| [Tags] Initiate_Factory_Reset_And_Verify |
| |
| Network Factory Reset |
| Software Manager Factory Reset |
| |
| # Enable field mode. |
| Enable Field Mode And Verify Unmount |
| |
| # Reboot BMC to apply BMC factory reset. |
| OBMC Reboot (off) |
| |
| # Check BMC comes up with same IP address. |
| Ping Host ${OPENBMC_HOST} |
| |
| # Check if factory reset has erased read-write and preserved volumes |
| # created by host BIOS and BMC. |
| |
| # Sample output: |
| # Filesystem 1K-blocks Used Available Use% Mounted on |
| # dev 215188 0 215188 0% /dev |
| # tmpfs 216104 14372 201732 7% /run |
| # /dev/mtdblock4 14720 14720 0 100% /run/initramfs/ro |
| # /dev/mtdblock5 4096 300 3796 7% /run/initramfs/rw |
| # cow 4096 300 3796 7% / |
| # tmpfs 216104 0 216104 0% /dev/shm |
| # tmpfs 216104 0 216104 0% /sys/fs/cgroup |
| # tmpfs 216104 0 216104 0% /tmp |
| # tmpfs 216104 80 216024 0% /var/volatile |
| # tmpfs 216104 0 216104 0% /usr/local |
| # ubi7:pnor-rw-9ac69aca 13816 16 13052 0% /media/pnor-rw-9ac69aca |
| # /dev/ubiblock7_1 19584 19584 0 100% /media/pnor-ro-9ac69aca |
| # ubi7:pnor-prsv 972 32 872 4% /media/pnor-prsv |
| # ubi7:pnor-patch 13816 16 13056 0% /usr/local/share/pnor |
| |
| # Check PNOR and BMC preserved volumes are not deleted. |
| |
| ${cmd_output} ${stderr} ${rc}= BMC Execute Command df |
| Should Contain ${cmd_output} pnor-rw msg=Host factory reset failed. |
| Should Contain ${cmd_output} pnor-prsv msg=Host factory reset failed. |
| Should Contain ${cmd_output} var msg=BMC factory reset failed. |
| |
| # Check PNOR read-write and preserved files are deleted. |
| ${cmd_output} ${stderr} ${rc}= BMC Execute Command ls /media/pnor-prsv |
| Should Be Empty ${cmd_output} msg=Host factory reset failed. |
| |
| # Check flag "Boot Device Selector" comes up with default value |
| # "No override" after BMC factory reset. |
| ${resp}= Run IPMI Standard Command chassis bootparam get 5 |
| ${boot_dev}= Get Lines Containing String ${resp} Boot Device Selector |
| Should Contain ${boot_dev} No override msg=BMC factory reset failed. |
| |
| *** Keywords *** |
| |
| Network Factory Reset |
| [Documentation] Network factory reset the BMC node. |
| |
| ${data}= Create Dictionary data=@{EMPTY} |
| Run Keyword And Ignore Error OpenBMC Post Request |
| ... ${NETWORK_MANAGER}/action/Reset data=${data} |
| |
| Software Manager Factory Reset |
| [Documentation] Software Manager Factory Reset. |
| |
| ${data}= Create Dictionary data=@{EMPTY} |
| Run Keyword And Ignore Error OpenBMC Post Request |
| ... ${SOFTWARE_VERSION_URI}/action/Reset data=${data} |
| |