| *** Settings *** |
| Documentation Check the indicator LEDs on the system can set the assert |
| ... property to the correct state. |
| |
| Resource ../../lib/rest_client.robot |
| Resource ../../lib/bmc_redfish_resource.robot |
| Resource ../../lib/bmc_redfish_utils.robot |
| Resource ../../lib/openbmc_ffdc.robot |
| Resource ../../lib/resource.robot |
| Resource ../../lib/boot_utils.robot |
| Library ../../lib/gen_robot_valid.py |
| Library ../../lib/gen_robot_keyword.py |
| |
| Suite Setup Suite Setup Execution |
| Suite Teardown Suite Teardown Execution |
| Test Setup Printn |
| Test Teardown Test Teardown Execution |
| |
| |
| *** Test Cases *** |
| |
| Verify LED Lamp Test Asserted At Standby |
| [Documentation] Verify the LED asserted at standby is set to off or blinking. |
| [Tags] Verify_LED_Lamp_Test_Asserted_At_Standby |
| [Template] Set and Verify Lamp LED Indicator |
| |
| # pre_req_state asserted expected_indicator_led |
| Off 1 Blinking |
| Off 0 Off |
| |
| |
| Verify LED Lamp Test Asserted At Runtime |
| [Documentation] Verify the LED asserted at runtime is set to off or blinking. |
| [Tags] Verify_LED_Lamp_Test_Asserted_At_Runtime |
| [Template] Set and Verify Lamp LED Indicator |
| |
| # pre_req_state asserted expected_indicator_led |
| On 1 Blinking |
| On 0 Off |
| |
| |
| Verify LED Power Supply Units Asserted At Standby |
| [Documentation] Verify the power supply units are asserted at standby to lit or off. |
| [Tags] Verify_LED_Power_Supply_Units_Asserted_At_Standby |
| [Template] Set and Verify LED Indicator |
| |
| # pre_req_state asserted expected_indicator_led |
| Off "xyz.openbmc_project.Led.Physical.Action.On" Lit |
| Off "xyz.openbmc_project.Led.Physical.Action.Off" Off |
| |
| |
| Verify LED Power Supply Units Asserted At Runtime |
| [Documentation] Verify the power supply units are asserted at runtime to lit or off. |
| [Tags] Verify_LED_Power_Supply_Units_Asserted_At_Runtime |
| [Template] Set and Verify LED Indicator |
| |
| # pre_req_state asserted expected_indicator_led |
| On "xyz.openbmc_project.Led.Physical.Action.On" Lit |
| On "xyz.openbmc_project.Led.Physical.Action.Off" Off |
| |
| |
| Verify LED Fans Asserted At Standby |
| [Documentation] Verify the fans are asserted at standby to lit or off. |
| [Tags] Verify_LED_Fans_Asserted_At_Standby |
| [Template] Set and Verify Fan LED Indicators |
| |
| # pre_req_state asserted expected_indicator_led |
| Off "xyz.openbmc_project.Led.Physical.Action.On" Lit |
| Off "xyz.openbmc_project.Led.Physical.Action.Off" Off |
| |
| |
| Verify LED Fans Asserted At Runtime |
| [Documentation] Verify the fans are asserted at runtime to lit or off. |
| [Tags] Verify_LED_Fans_Asserted_At_Runtime |
| [Template] Set and Verify Fan LED Indicators |
| |
| # pre_req_state asserted expected_indicator_led |
| On "xyz.openbmc_project.Led.Physical.Action.On" Lit |
| On "xyz.openbmc_project.Led.Physical.Action.Off" Off |
| |
| |
| *** Keywords *** |
| |
| Set and Verify Lamp LED Indicator |
| [Documentation] Verify the indicator LED for the group lamp test is asserted. |
| [Arguments] ${pre_req_state} ${asserted} ${expected_indicator_led} |
| |
| # Description of Arguments(s): |
| # pre_req_state The pre-requisite state of the host to perform the test (e.g. "On") |
| # asserted The assert property that sets the value to 0 - Off or 1 - Blinking (e.g. "1") |
| # expected_indicator_led The expected value of the IndicatorLED attribute for all the |
| # LEDs after the lamp test is initiated (e.g. "Blinking") |
| |
| Run Key U Redfish Power ${pre_req_state} \ stack_mode=skip \ quiet=1 |
| Redfish.Login |
| |
| Redfish.Put ${LED_LAMP_TEST_ASSERTED_URI}attr/Asserted body={"data":${asserted}} |
| |
| # Example result: |
| # power_supplies: |
| # [0]: |
| # [MemberId]: powersupply0 |
| # [PartNumber]: 02CL396 |
| # [IndicatorLED]: Blinking |
| # [EfficiencyPercent]: 90 |
| # [Status]: |
| # [Health]: OK |
| # [State]: Enabled |
| |
| Verify Indicator LEDs ${expected_indicator_led} |
| |
| |
| Set and Verify LED Indicator |
| [Documentation] Verify the indicator LED for the power supply units are asserted. |
| [Arguments] ${pre_req_state} ${asserted} ${expected_indicator_led} |
| |
| # Description of Arguments(s): |
| # pre_req_state The pre-requisite state of the host to perform the test (e.g. "On") |
| # asserted The assert property that sets the value |
| # (e.g. "xyz.openbmc_project.Led.Physical.Action.On") |
| # expected_indicator_led The expected value of the IndicatorLED attribute for all the |
| # power supplies units are initiated (e.g. "Lit") |
| |
| Run Key U Redfish Power ${pre_req_state} \ stack_mode=skip \ quiet=1 |
| Redfish.Login |
| |
| # Put both power supply LEDs On/Off to check all units are asserted |
| Redfish.Put ${LED_PHYSICAL_PS0_URI}attr/State body={"data":${asserted}} |
| Redfish.Put ${LED_PHYSICAL_PS1_URI}attr/State body={"data":${asserted}} |
| |
| # Example output: |
| # power_supplies: |
| # [0]: |
| # [MemberId]: powersupply0 |
| # [IndicatorLED]: Lit |
| # [Status]: |
| # [Health]: OK |
| # [State]: Enabled |
| # [1]: |
| # [MemberId]: powersupply1 |
| # [IndicatorLED]: Lit |
| # [Status]: |
| # [Health]: OK |
| # [State]: Enabled |
| |
| Verify Indicator LEDs ${expected_indicator_led} |
| |
| |
| Verify Indicator LEDs |
| [Documentation] Verify the LEDs on the power supply units are set according to caller's expectation. |
| [Arguments] ${expected_indicator_led} |
| |
| # Description of Arguments(s): |
| # expected_indicator_led The expected value of the IndicatorLED attribute for all the |
| # LEDs after the lamp test is initiated (e.g. "Blinking") |
| |
| ${power_supplies}= Redfish.Get Attribute ${REDFISH_CHASSIS_POWER_URI} PowerSupplies |
| Rprint Vars power_supplies |
| FOR ${power_supply_leds} IN @{power_supplies} |
| Valid Value power_supply_leds['IndicatorLED'] ['${expected_indicator_led}'] |
| END |
| |
| |
| Set and Verify Fan LED Indicators |
| [Documentation] Verify the indicator LED for the fans are asserted. |
| [Arguments] ${pre_req_state} ${asserted} ${expected_indicator_led} |
| |
| # Description of Arguments(s): |
| # pre_req_state The pre-requisite state of the host to perform the test (e.g. "On") |
| # asserted The assert property that sets the value |
| # (e.g. "xyz.openbmc_project.Led.Physical.Action.On") |
| # expected_indicator_led The expected value of the IndicatorLED attribute for all the fans |
| # are initiated (e.g. "Lit") |
| |
| Run Key U Redfish Power ${pre_req_state} \ stack_mode=skip \ quiet=1 |
| Redfish.Login |
| |
| # Put all the fan LEDs On/Off to check all are asserted |
| Redfish.Put ${LED_PHYSICAL_FAN0_URI}attr/State body={"data":${asserted}} |
| Redfish.Put ${LED_PHYSICAL_FAN2_URI}attr/State body={"data":${asserted}} |
| Redfish.Put ${LED_PHYSICAL_FAN3_URI}attr/State body={"data":${asserted}} |
| |
| # Example output: |
| # fans: |
| # [0]: |
| # [@odata.id]: /redfish/v1/Chassis/chassis/Thermal#/Fans/0 |
| # [@odata.type]: #Thermal.v1_3_0.Fan |
| # [IndicatorLED]: Lit |
| # [MemberId]: fan0_0 |
| # [Name]: fan0 0 |
| # [Status]: |
| # [Health]: OK |
| # [State]: Enabled |
| |
| ${fans}= Redfish.Get Attribute ${REDFISH_CHASSIS_THERMAL_URI} Fans |
| Rprint Vars fans |
| FOR ${fan_leds} IN @{fans} |
| Valid Value fan_leds['IndicatorLED'] ['${expected_indicator_led}'] |
| END |
| |
| |
| Suite Teardown Execution |
| [Documentation] Do the post suite teardown. |
| |
| Redfish.Logout |
| |
| |
| Suite Setup Execution |
| [Documentation] Do test case setup tasks. |
| |
| Printn |
| Redfish.Login |
| |
| |
| Test Teardown Execution |
| [Documentation] Do the post test teardown. |
| |
| FFDC On Test Case Fail |