| # https://github.com/openbmc/openbmc-test-automation/issues/822 | 
 | -e Verify_Minimal_Memory_Buffer_Inventory | 
 | -e Verify_Minimal_Main_Planar_Inventory | 
 | -e Verify_Minimal_System_Inventory | 
 | # NA test case for Witherspoon | 
 | -e io_board_Present | 
 | -e io_board_Fault | 
 | # System LED test cases which are NA for Witherspoon system. | 
 | -e Test_Heartbeat_LED_And_Verify_Via_REST | 
 | -e Test_Beep_LED_And_Verify_Via_REST | 
 | -e Test_Identify_LED_And_Verify_Via_REST | 
 | # NXDMAENG UE error injection is not available in latest p9dd1ffdcv104.xlsm | 
 | -e Verify_Unrecoverable_Callout_Handling_For_NXDMAENG | 
 | # NA test case with nginx support. | 
 | -e Test_Non_SSL_Connection_To_Port_80 | 
 | -e Test_Non_SSL_Connection_To_Port_443 | 
 | # MRW changes required for this to work. | 
 | -e Test_GPU_SDR_Info_At_Power_On | 
 | # Core dump is disabled. | 
 | -e Verify_Core_Dump_Size | 
 | # Skip org code update. | 
 | -e Initiate_Code_Update_BMC | 
 | -e BIOS_Code_Update | 
 | -e Upload_Test | 
 | -e BMC_Code_Update | 
 | -e Host_Code_Update | 
 | -e BMC_Update_Recoverable_Error | 
 | -e Host_Update_Recoverable_Error | 
 | -e BMC_Multi_Code_Update | 
 | -e Host_Multi_Code_Update | 
 | -e Verify_IPMI_Disable_Policy_Post_BMC_Code_Update | 
 | # Others NA tests. | 
 | -e Run_Keyword_Pgm | 
 | # Factory reset must not run in CT. | 
 | -e Factory_Reset | 
 | -e Full_Suite_Regression | 
 | -e AC_Cycles | 
 | -e Network_Nping | 
 | # Multiple runs only needed for stability. | 
 | -e Run_Multiple_Power_Cycle | 
 | -e Run_Multiple_BMC_Reset_Via_REST | 
 | -e Run_Multiple_BMC_Reset_Via_Reboot | 
 | -e General_boot_testing | 
 | -e SLP_Service_Test | 
 | -e Check_Network_Latency | 
 | # TODO: Configure invalid IP address use cases. | 
 | -e Configure_Broadcast_IP | 
 | -e Configure_Multicast_IP | 
 | -e Configure_Loopback_IP | 
 | -e Configure_Network_ID | 
 | # TODO: Invalid gateway address configuration. | 
 | -e Configure_Broadcast_IP_For_Gateway | 
 | -e Configure_Loopback_IP_For_Gateway | 
 | -e Configure_Multicast_IP_For_Gateway | 
 | -e Configure_Network_ID_For_Gateway | 
 | -e Verify_Network_Interface_Recovery | 
 | # Skipping RAS test cases | 
 | -e Host_RAS | 
 | # Skip multi threading test causing XML parser failure. | 
 | -e Stress_BMC_REST_Server | 
 | -e Stress_BMC_SSH_Server | 
 | -e Stress_BMC_IPMI_Server | 
 | # Applicable only for master build. | 
 | -e Verify_eSEL_Description_And_EntryID_Using_REST | 
 | # Needs fix and improvement. | 
 | -e Test_SBE_Side_Switch | 
 | # IPMI disable and enable use cases. | 
 | -e Verify_Disabling_And_Enabling_IPMI_Via_Host | 
 | -e Verify_Disabling_IPMI_Via_OOB_IPMI | 
 | -e Verify_IPMI_Disable_Persistency_After_BMC_Reboot | 
 | # Remote logging | 
 | -e Verify_BMC_Journald_Contains_No_Credential_Data | 
 | # Non bmcweb certificate. | 
 | -e Certificate_Test |