| *** Settings *** |
| Documentation Module to test IPMI cold and warm reset functionalities. |
| |
| Resource ../lib/ipmi_client.robot |
| Resource ../lib/openbmc_ffdc.robot |
| |
| Test Teardown FFDC On Test Case Fail |
| |
| *** Variables *** |
| |
| # User may pass LOOP_COUNT. |
| ${LOOP_COUNT} ${1} |
| |
| *** Test Cases *** |
| |
| Test IPMI Warm Reset |
| [Documentation] Check IPMI warm reset and wait for BMC to become online. |
| [Tags] Test_IPMI_Warm_Reset |
| Repeat Keyword ${LOOP_COUNT} times IPMI MC Reset Warm (off) |
| |
| |
| Test IPMI Cold Reset |
| [Documentation] Check IPMI cold reset and wait for BMC to become online. |
| [Tags] Test_IPMI_Cold_Reset |
| |
| Repeat Keyword ${LOOP_COUNT} times IPMI MC Reset Cold (off) |
| |
| |
| Verify BMC Power Cycle via IPMI |
| [Documentation] Verify IPMI power cycle command works fine. |
| [Tags] Verify_BMC_Power_Cycle_via_IPMI |
| |
| Redfish Power On stack_mode=skip quiet=1 |
| Run IPMI Standard Command chassis power cycle |
| Wait Until Keyword Succeeds 3 min 10 sec Is IPMI Chassis Off |
| Wait Until Keyword Succeeds 3 min 10 sec Is IPMI Chassis On |
| |
| |
| *** Keywords *** |
| |
| Is IPMI Chassis Off |
| [Documentation] Check if chassis state is "Off" via IPMI. |
| ${power_state}= Get Chassis Power State |
| Should Be Equal ${power_state} Off |
| |
| |
| Is IPMI Chassis On |
| [Documentation] Check if chassis state is "On" via IPMI. |
| ${power_state}= Get Chassis Power State |
| Should Be Equal ${power_state} On |