blob: 47e13aa755a59792f47318ca67520d7f43c23907 [file] [log] [blame]
*** Settings ***
Documentation This suite verifies the power restore policy supported by
... REST Interfaces.
... Refer here for documentation on the REST interfaces
... https://github.com/openbmc/docs/blob/master/rest-api.md
Resource ../lib/rest_client.robot
Resource ../lib/pdu/pdu.robot
Resource ../lib/utils.robot
Resource ../lib/openbmc_ffdc.robot
Resource ../lib/boot/boot_resource_master.robot
Library SSHLibrary
Test Teardown Log FFDC
Force Tags chassisboot bmcreboot
*** Variables ***
${HOST_SETTING} /org/openbmc/settings/host0
*** Test Cases ***
Set the power restore policy
#Policy Expected System State Next System State
LEAVE_OFF HOST_POWERED_OFF HOST_POWERED_OFF
LEAVE_OFF HOST_BOOTED HOST_POWERED_OFF
ALWAYS_POWER_ON HOST_POWERED_OFF HOST_BOOTED
ALWAYS_POWER_ON HOST_BOOTED HOST_BOOTED
RESTORE_LAST_STATE HOST_BOOTED HOST_BOOTED
RESTORE_LAST_STATE HOST_POWERED_OFF HOST_POWERED_OFF
[Documentation] Test to validate restore policy attribute functionality.
... Policy:
... System policy to restore on power cycle
... Expected System State:
... State where system should be before running the
... test case
... Next System State:
... After power cycle, system should reach this
... specific state
[Template] Set Restore Policy
***keywords***
Set Restore Policy
[arguments] ${policy} ${expectedState} ${nextState}
Set Policy Setting ${policy}
${currentState}=
... Read Attribute ${HOST_SETTING} system_state
Log Current System State= ${currentState}
Log Expected System State= ${expectedState}
Log Next System State= ${nextState}
Run Keyword If
... '${currentState}' != '${expectedState}'
... Set Initial Test State ${expectedState}
Log "Doing power cycle"
PDU Power Cycle
Check If BMC is Up 5 min 10 sec
Log "BMC is Online now"
Wait Until Keyword Succeeds
... 5 min 10 sec System State ${nextState}
Set Policy Setting
[Documentation] Set the given test policy
[arguments] ${policy}
${valueDict} = create dictionary data=${policy}
Write Attribute ${HOST_SETTING} power_policy data=${valueDict}
${currentPolicy}= Read Attribute ${HOST_SETTING} power_policy
Should Be Equal ${currentPolicy} ${policy}
Set Initial Test State
[Documentation] Poweron if ON expected, Poweroff if OFF expected
... to initial state of the test.
[arguments] ${expectedState}
Run Keyword If
... '${expectedState}' == 'HOST_BOOTED'
... BMC Power On
Run Keyword If
... '${expectedState}' == 'HOST_POWERED_OFF'
... BMC Power Off
System State
[arguments] ${nextState}
${afterPduSystemState}=
... Read Attribute ${HOST_SETTING} system_state
Should be equal ${afterPduSystemState} ${nextState}