blob: 07dce0ef414f6379422ece8c95b1982e1fe3004c [file] [log] [blame]
*** Settings ***
Documentation Module to test dcmi get temperature reading functionality.
Resource ../../lib/ipmi_client.robot
Resource ../../lib/openbmc_ffdc.robot
Resource ../../lib/bmc_network_utils.robot
Resource ../../lib/boot_utils.robot
Variables ../../data/ipmi_raw_cmd_table.py
Variables ../../data/dcmi_raw_cmd_table.py
Variables ../../data/ipmi_variable.py
Library ../../lib/bmc_network_utils.py
Library ../../lib/ipmi_utils.py
Library ../../lib/utilities.py
Library JSONLibrary
Suite Setup Suite Setup Execution
Force Tags DCMI_Get_Temperature_Reading
*** Variables ***
${config_file_name} dcmi_sensors.json
${dcmi_sensors_info_json_file} /usr/share/ipmi-providers/${config_file_name}
${client_config_file_path} ${EXEC_DIR}/${config_file_name}
&{dcmi_sensor_uri}
*** Test Cases ***
Verify Get Temperature Reading Command For Inlet Temperature Sensor
[Documentation] Verify IPMI Get Temperature Reading command for inlet temperature sensor.
[Tags] Verify_Get_Temperature_Reading_Command_For_Inlet_Temperature_Sensor
${cmd}= Catenate ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][0]}
... ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][1]} 0x00 0x00
${ipmi_resp}= Run IPMI Command ${cmd}
Verify Reading With IPMI ${ipmi_resp} ${1} inlet
# Verify Temperature Reading With Dbus URI ${ipmi_resp} inlet ${1}
Verify Get Temperature Reading Command For CPU 0 Temperature Sensor
[Documentation] Verify IPMI Get Temperature Reading command for cpu0 temperature sensor.
[Tags] Verify_Get_Temperature_Reading_Command_For_CPU_0_Temperature_Sensor
${cmd}= Catenate ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][0]}
... ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][2]} 0x00 0x00
${ipmi_resp}= Run IPMI Command ${cmd}
Verify Reading With IPMI ${ipmi_resp} ${1} cpu
# Verify Temperature Reading With Dbus URI ${ipmi_resp} cpu ${1}
Verify Get Temperature Reading Command For CPU 1 Temperature Sensor
[Documentation] Verify IPMI Get Temperature Reading command for cpu1 temperature sensor.
[Tags] Verify_Get_Temperature_Reading_Command_For_CPU_1_Temperature_Sensor
${cmd}= Catenate ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][0]}
... ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][2]} 0x00 0x00
${ipmi_resp}= Run IPMI Command ${cmd}
Verify Reading With IPMI ${ipmi_resp} ${2} cpu
# Verify Temperature Reading With Dbus URI ${ipmi_resp} cpu ${2}
Verify Get Temperature Reading Command For Baseboard Temperature Sensor
[Documentation] Verify IPMI Get Temperature Reading command for baseboard temperature sensor.
[Tags] Verify_Get_Temperature_Reading_Command_For_Baseboard_Temperature_Sensor
${cmd}= Catenate ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][0]}
... ${DCMI_RAW_CMD['DCMI']['GET_TEMPERATURE_READING'][3]} 0x00 0x00
${ipmi_resp}= Run IPMI Command ${cmd}
Verify Reading With IPMI ${ipmi_resp} ${1} baseboard
# Verify Temperature Reading With Dbus URI ${ipmi_resp} baseboard ${1}
*** Keywords ***
Suite Setup Execution
[Documentation] Get dcmi sensors uri from config file.
IPMI Power On stack_mode=skip quiet=1
# Get this file to client machine /usr/share/ipmi-providers/dcmi_sensors.json
scp.Open Connection
... ${OPENBMC_HOST} username=${OPENBMC_USERNAME} password=${OPENBMC_PASSWORD} port=${SSH_PORT}
scp.Get File ${dcmi_sensors_info_json_file} ${EXEC_DIR}
scp.Close Connection
${config_file}= OperatingSystem.Get File ${client_config_file_path}
${config_file_response}= Evaluate json.loads('''${config_file}''') json
${remove_configuration_file}= Catenate rm -rf ${client_config_file_path}
${rc} ${output}= Shell Cmd ${remove_configuration_file}
FOR ${key} ${value} IN &{config_file_response}
&{tmp}= Create Dictionary
FOR ${response} IN @{value}
${sensor_dbus}= Get From Dictionary ${response} dbus
${instance}= Get From Dictionary ${response} instance
Set To Dictionary ${tmp} ${instance} ${sensor_dbus}
END
Set To Dictionary ${dcmi_sensor_uri} ${key} ${tmp}
END
Verify Temperature Reading With Dbus URI
[Documentation] Verify temperature from ipmi response and json file.
[Arguments] ${ipmi_resp} ${key} ${instance}
# Description of argument(s):
# ipmi_resp IPMI command response.
# key Entity ID description i.e inlet, cpu, baseboard.
# instance instance number 1, 2, ..
${dbus_uris}= Get From Dictionary ${dcmi_sensor_uri} ${key}
${dbus_uri}= Get From Dictionary ${dbus_uris} ${instance}
${get_reading_value}= Set Variable If
... '${instance}' == '1' ${3}
... '${instance}' == '2' ${5}
${ipmi_resp_list}= Split String ${ipmi_resp}
${temperature_reading}= Get From List ${ipmi_resp_list} ${get_reading_value}
${temp_reading}= Convert To Integer ${temperature_reading} 16
${busctl_cmd}= Catenate busctl introspect xyz.openbmc_project.HwmonTempSensor ${dbus_uri}
${busctl_cmd_resp}= BMC Execute Command ${busctl_cmd}
${current_temp_value_from_dbus}= Get Regexp Matches ${busctl_cmd_resp[0]}
... \\.Value\\s+property\\s+d\\s+(\\S+)\\s 1
${min_value}= Evaluate ${temp_reading} - 1
${max_value}= Evaluate ${temp_reading} + 1
Check Reading Value In D-Bus
[Documentation] Verify temperature from ipmi response and json file.
[Arguments] ${key} ${instance} ${dcmi_reading_value}
# Description of argument(s):
# key Entity ID description i.e inlet, cpu, baseboard.
# instance instance number 1, 2, ..
${dbus_uris}= Get From Dictionary ${dcmi_sensor_uri} ${key}
${dbus_uri}= Get From Dictionary ${dbus_uris} ${instance}
${busctl_cmd}= Catenate busctl introspect xyz.openbmc_project.HwmonTempSensor ${dbus_uri}
${busctl_cmd_resp}= BMC Execute Command ${busctl_cmd}
${current_temp_value_from_dbus}= Get Regexp Matches ${busctl_cmd_resp[0]}
... \\.Value\\s+property\\s+d\\s+(\\S+)\\s 1
Run Keyword If '${current_temp_value_from_dbus[0]}' == 'nan' and '${dcmi_reading_value}' == '0'
... Fail msg=sensor reading value is not present.
Run Keyword If '${current_temp_value_from_dbus[0]}' != 'nan' and '${dcmi_reading_value}' == '0'
... Fail msg=sensor reading value is showing as 0 in dcmi get temperature raw command.
${dbus_reading_value}= Set Variable .${current_temp_value_from_dbus[0].split(".")[1].strip()}
${status}= Run Keyword And Return Status Should Be True ${dbus_reading_value} > .499
Run Keyword If ${status} == False
... Fail msg=sensor reading value is showing wrongly in dcmi get temperature raw command.
${dbus_reading_value}= Set Variable ${current_temp_value_from_dbus[0].split(".")[0].strip()}
Should Be Equal ${dcmi_reading_value} ${dbus_reading_value}
... msg=sensor reading value is showing wrongly in dcmi get temperature raw command.
Verify Reading With IPMI
[Documentation] Verify temperature reading with ipmi command.
[Arguments] ${ipmi_resp} ${instance} ${key}
# Description of argument(s):
# ipmi_resp IPMI command response.
# instance instance number 1, 2, ..
# key Entity ID description i.e inlet, cpu, baseboard.
${get_reading_value}= Set Variable If
... '${instance}' == '1' ${3}
... '${instance}' == '2' ${5}
${ipmi_resp_list}= Split String ${ipmi_resp}
${temperature_reading}= Get From List ${ipmi_resp_list} ${get_reading_value}
${dcmi_reading}= Convert To Integer ${temperature_reading} 16
Run Keyword If '${dcmi_reading}' == '0'
... Check Reading Value In D-Bus ${key} ${instance} ${dcmi_reading}
${dcmi_temp_reading}= Convert To String ${dcmi_reading}
${ipmi_sensor_cmd_resp}= Get IPMI Sensor Reading ${key} ${instance}
${ipmi_sensor_cmd_resp_list}= Split String ${ipmi_sensor_cmd_resp} |
${ipmi_temp_reading}= Set Variable ${ipmi_sensor_cmd_resp_list[1].strip().split(".")[0]}
${reading_status}= Run Keyword And Return Status Should Be Equal
... ${dcmi_temp_reading} ${ipmi_temp_reading}
Run Keyword If ${reading_status} == False
... Check Reading Value In D-Bus ${key} ${instance} ${dcmi_temp_reading}
Get IPMI Sensor Reading
[Documentation] Return ipmi sensor reading.
[Arguments] ${key} ${instance}
# Description of argument(s):
# instance Entity ID description i.e inlet, cpu, baseboard.
# index Selecting the corresponding sensor dbus uri from list.
${dbus_uris}= Get From Dictionary ${dcmi_sensor_uri} ${key}
${dbus_uri}= Get From Dictionary ${dbus_uris} ${instance}
${sensor_name}= Set Variable ${dbus_uri.split('/')[-1]}
${sensor_format}= Run IPMI Standard Command sensor
${sensor_name_status}= Run Keyword And Return Status Should Contain
... ${sensor_format} _
${sensor_name}= Run Keyword If ${sensor_name_status} == True
... Set Variable ${sensor_name_dbus}
... ELSE
... Replace String ${sensor_name} _ ${SPACE}
${ret}= Run External IPMI Standard Command sensor | grep -i "${sensor_name}"
[Return] ${ret}