| # https://github.com/openbmc/openbmc/issues/1142 |
| -e Check_BMC_Name_Property_Is_Set |
| -e Check_BMC_Clocks_Name_Property_Is_Set |
| -e Check_BMC_Clocks_Compatible_Property_Is_Set |
| -e Check_BMC_FSI_Compatible_Property_Is_Set |
| -e Check_BMC_FSI_Name_Property_Is_Set |
| # https://github.com/openbmc/openbmc-test-automation/issues/822 |
| -e Verify_Minimal_Memory_Buffer_Inventory |
| -e Verify_Minimal_Main_Planar_Inventory |
| -e Verify_Minimal_System_Inventory |
| # NA test case for Witherspoon |
| -e io_board_Present |
| -e io_board_Fault |
| # System LED test cases which are NA for Witherspoon system. |
| -e Test_Heartbeat_LED_And_Verify_Via_REST |
| -e Test_Beep_LED_And_Verify_Via_REST |
| -e Test_Identify_LED_And_Verify_Via_REST |
| # NXDMAENG UE error injection is not available in latest p9dd1ffdcv104.xlsm |
| -e Verify_Unrecoverable_Callout_Handling_For_NXDMAENG |
| # NA test case with nginx support. |
| -e Test_Non_SSL_Connection_To_Port_80 |
| -e Test_Non_SSL_Connection_To_Port_443 |
| # MRW changes required for this to work. |
| -e Test_GPU_SDR_Info_At_Power_On |
| # Core dump is disabled. |
| -e Verify_Core_Dump_Size |
| # Skip org code update. |
| -e Initiate_Code_Update_BMC |
| -e BIOS_Code_Update |
| -e Upload_Test |
| -e BMC_Code_Update |
| -e Host_Code_Update |
| -e BMC_Update_Recoverable_Error |
| -e Host_Update_Recoverable_Error |
| -e BMC_Multi_Code_Update |
| -e Host_Multi_Code_Update |
| -e Verify_IPMI_Disable_Policy_Post_BMC_Code_Update |
| # Others NA tests. |
| -e Run_Keyword_Pgm |
| # Factory reset must not run in CT. |
| -e Factory_Reset |
| -e Full_Suite_Regression |
| -e AC_Cycles |
| -e Network_Nping |
| # Multiple runs only needed for stability. |
| -e Run_Multiple_Power_Cycle |
| -e Run_Multiple_BMC_Reset_Via_REST |
| -e Run_Multiple_BMC_Reset_Via_Reboot |
| -e General_boot_testing |
| -e SLP_Service_Test |
| -e Check_Network_Latency |
| # TODO: Configure invalid IP address use cases. |
| -e Configure_Broadcast_IP |
| -e Configure_Multicast_IP |
| -e Configure_Loopback_IP |
| -e Configure_Network_ID |
| # TODO: Invalid gateway address configuration. |
| -e Configure_Broadcast_IP_For_Gateway |
| -e Configure_Loopback_IP_For_Gateway |
| -e Configure_Multicast_IP_For_Gateway |
| -e Configure_Network_ID_For_Gateway |
| -e Verify_Network_Interface_Recovery |
| # Skipping RAS test cases |
| -e Host_RAS |
| # Skip multi threading test cuasing XML parser failure. |
| -e Stress_BMC_REST_Server |
| -e Stress_BMC_SSH_Server |
| -e Stress_BMC_IPMI_Server |
| # Applicable only for master build. |
| -e Verify_eSEL_Description_And_EntryID_Using_REST |
| # Needs fix and improvement. |
| -e Test_SBE_Side_Switch |
| # IPMI disable and enable use cases. |
| -e Verify_Disabling_And_Enabling_IPMI_Via_Host |
| -e Verify_Disabling_IPMI_Via_OOB_IPMI |
| -e Verify_IPMI_Disable_Persistency_After_BMC_Reboot |
| # Remote logging |
| -e Verify_BMC_Journald_Contains_No_Credential_Data |
| # Non bmcweb certificate. |
| -e Certificate_Test |