| *** Settings *** |
| Documentation Power cycle loop. This is to test where network service |
| ... becomes unavailable during AC-Cycle stress test. |
| |
| Resource ../lib/rest_client.robot |
| Resource ../lib/pdu/pdu.robot |
| Resource ../lib/utils.robot |
| Resource ../lib/openbmc_ffdc.robot |
| Resource ../lib/state_manager.robot |
| Resource ../lib/boot_utils.robot |
| |
| Test Teardown Test Exit Logs |
| |
| *** Variables *** |
| ${LOOP_COUNT} ${50} |
| |
| *** Test Cases *** |
| |
| Run Multiple Power Cycle |
| [Documentation] Execute multiple power cycles. |
| [Setup] Validate Parameters |
| [Tags] Run_Multiple_Power_Cycle |
| |
| # By default run test for 50 loops, else user input iteration. |
| # Fails immediately if any of the execution rounds fail and |
| # check if BMC is still pinging and FFDC is collected. |
| Repeat Keyword ${LOOP_COUNT} times Power Cycle System Via PDU |
| |
| |
| Run Multiple BMC Reset Via REST |
| [Documentation] Execute multiple reboots via REST. |
| [Tags] Run_Multiple_BMC_Reset_Via_REST |
| |
| # By default run test for 50 loops, else user input iteration. |
| # Fails immediately if any of the execution rounds fail and |
| # check if BMC is still pinging and FFDC is collected. |
| Repeat Keyword ${LOOP_COUNT} times BMC REST Reset Cycle |
| |
| |
| Run Multiple BMC Reset Via Reboot |
| [Documentation] Execute multiple reboots via "reboot" command. |
| [Tags] Run_Multiple_BMC_Reset_Via_Reboot |
| |
| # By default run test for 50 loops, else user input iteration. |
| # Fails immediately if any of the execution rounds fail and |
| # check if BMC is still pinging and FFDC is collected. |
| Repeat Keyword ${LOOP_COUNT} times BMC Reboot Cycle |
| |
| |
| *** Keywords *** |
| |
| Power Cycle System Via PDU |
| [Documentation] Power cycle system and wait for BMC to reach Ready state. |
| Log "Doing power cycle" |
| PDU Power Cycle |
| Check If BMC Is Up 5 min 10 sec |
| |
| Wait Until Keyword Succeeds 10 min 10 sec Is BMC Ready |
| |
| |
| BMC REST Reset Cycle |
| [Documentation] Reset BMC via REST and wait for ready state. |
| Log "Doing Reboot cycle" |
| ${bmc_version_before}= Get BMC Version |
| Initiate BMC Reboot |
| Wait Until Keyword Succeeds 10 min 10 sec Is BMC Ready |
| ${bmc_version_after}= Get BMC Version |
| Should Be Equal ${bmc_version_before} ${bmc_version_after} |
| |
| |
| BMC Reboot Cycle |
| [Documentation] Reboot BMC and wait for ready state. |
| Log "Doing Reboot cycle" |
| ${bmc_version_before}= Get BMC Version |
| OBMC Reboot (off) stack_mode=normal |
| ${bmc_version_after}= Get BMC Version |
| Should Be Equal ${bmc_version_before} ${bmc_version_after} |
| |
| |
| Test Exit Logs |
| Ping Host ${OPENBMC_HOST} |
| FFDC On Test Case Fail |
| |
| |
| Validate Parameters |
| Should Not Be Empty ${PDU_IP} |
| Should Not Be Empty ${PDU_TYPE} |
| Should Not Be Empty ${PDU_SLOT_NO} |
| Should Not Be Empty ${PDU_USERNAME} |
| Should Not Be Empty ${PDU_PASSWORD} |
| |