| *** Settings *** |
| |
| Documentation This suite is for testing esel's mechanism of checking Reservation_ID. |
| |
| Resource ../lib/ipmi_client.robot |
| Resource ../lib/openbmc_ffdc.robot |
| |
| Suite Setup Open Connection And Log In |
| Suite Teardown Close All Connections |
| Test Teardown FFDC On Test Case Fail |
| |
| *** Test Cases *** |
| |
| Test Wrong Reservation_ID |
| [Documentation] This testcase is to test BMC can handle multi-requestor's |
| ... oem partial add command with incorrect reservation id. |
| ... It simulates sending partial add command with fake content |
| ... and wrong Reservation ID. This command will be rejected. |
| [Tags] Test_Wrong_Reservation_ID |
| |
| ${rev_id_1} = Run IPMI Command Returned 0x0a 0x42 |
| ${rev_id_ls} = Get Substring ${rev_id_1} 1 3 |
| ${rev_id_ms} = Get Substring ${rev_id_1} -2 |
| Run IPMI command 0x0a 0x42 |
| ${output} = Check IPMI Oempartialadd Reject 0x32 0xf0 0x${rev_id_ls} 0x${rev_id_ms} 0 0 0 0 0 1 2 3 4 5 6 7 8 9 0xa 0xb 0xc 0xd 0xe 0xf |
| Should Contain ${output} Reservation cancelled |
| |
| Test Correct Reservation_ID |
| [Documentation] This testcase is to test BMC can handle multi-requestor's |
| ... oem partial add command with correct reservation id. It |
| ... simulates sending partial add command with fake content |
| ... and correct Reservation ID. This command will be accepted. |
| [Tags] Test_Correct_Reservation_ID |
| |
| Run IPMI command 0x0a 0x42 |
| ${rev_id_2} = Run IPMI Command Returned 0x0a 0x42 |
| ${rev_id_ls} = Get Substring ${rev_id_2} 1 3 |
| ${rev_id_ms} = Get Substring ${rev_id_2} -2 |
| ${output} = Check IPMI Oempartialadd Accept 0x32 0xf0 0x${rev_id_ls} 0x${rev_id_ms} 0 0 0 0 0 1 2 3 4 5 6 7 8 9 0xa 0xb 0xc 0xd 0xe 0xf |
| Should Be Empty ${output} |
| |
| Clear Test File |
| [Documentation] Clear /tmp/esel |
| |
| Execute Command rm /tmp/esel |
| Execute Command sync |
| |
| *** Keywords *** |
| |
| Run IPMI Command Returned |
| [arguments] ${args} |
| ${output_1} = Execute Command /tmp/ipmitool -I dbus raw ${args} |
| [return] ${output_1} |
| |
| Check IPMI Oempartialadd Reject |
| [arguments] ${args} |
| ${stdout} ${stderr} ${output_2}= Execute Command /tmp/ipmitool -I dbus raw ${args} return_stdout=True return_stderr= True return_rc=True |
| [return] ${stderr} |
| |
| Check IPMI Oempartialadd Accept |
| [arguments] ${args} |
| ${stdout} ${stderr} ${output_3} = Execute Command /tmp/ipmitool -I dbus raw ${args} return_stdout=True return_stderr= True return_rc=True |
| Should Be Equal ${output_3} ${0} msg=${stderr} |
| [return] ${stderr} |
| |