| *** Settings *** |
| Documentation Test setting VLAN and its configuration. |
| |
| |
| Resource ../lib/rest_client.robot |
| Resource ../lib/ipmi_client.robot |
| Resource ../lib/utils.robot |
| Resource ../lib/common_utils.robot |
| Resource ../lib/openbmc_ffdc.robot |
| Resource ../lib/ipmi_client.robot |
| Resource ../lib/bmc_network_utils.robot |
| Resource ../lib/state_manager.robot |
| Library ../lib/utilities.py |
| Library ../lib/ipmi_utils.py |
| Library ../lib/var_funcs.py |
| Library Collections |
| |
| Suite Teardown Suite Teardown Execution |
| |
| |
| *** Variables *** |
| ${vlan_id} ${53} |
| ${invalid_vlan_id} abc |
| ${vlan_resource} ${NETWORK_MANAGER}action/VLAN |
| ${network_resource} xyz.openbmc_project.Network.IP.Protocol.IPv4 |
| ${static_network_resource} xyz.openbmc_project.Network.IP.AddressOrigin.Static |
| ${ip} 10.6.6.10 |
| ${netmask} ${24} |
| ${gateway} 0.0.0.0 |
| ${initial_vlan_config} @{EMPTY} |
| |
| |
| *** Test Cases *** |
| |
| |
| Add VLAN Via REST And Verify |
| [Documentation] Add VLAN via REST and verify it via REST and IPMI. |
| [Tags] Add_VLAN_Via_REST_And_Verify |
| [Setup] Test Setup Execution |
| [Teardown] Delete VLAN ${vlan_id} |
| |
| Create VLAN ${vlan_id} |
| Verify Existence Of VLAN ${vlan_id} |
| |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['802.1q VLAN ID'] ["${vlan_id}"] |
| |
| |
| Add Invalid VLAN Via REST And Verify |
| [Documentation] Add Invalid VLAN via REST and verify. |
| [Tags] Add_Invalid_VLAN_Via_REST_And_Verify |
| |
| Create VLAN ${invalid_vlan_id} expected_result=error |
| |
| |
| Delete VLAN Via REST |
| [Documentation] Delete VLAN via REST and verify it via REST and IPMI. |
| [Tags] Delete_VLAN_Via_REST |
| [Setup] Run Keywords Test Setup Execution AND Create VLAN ${vlan_id} |
| |
| Verify Existence Of VLAN ${vlan_id} |
| Delete VLAN ${vlan_id} |
| Verify Existence Of VLAN ${vlan_id} expected_result=error |
| |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['802.1q VLAN ID'] ["Disabled"] |
| |
| |
| Configure Network Settings On VLAN Via REST |
| [Documentation] Configure IP on VLAN and verify it via REST and IPMI. |
| [Tags] Configure_Network_Settings_On_VLAN_Via_REST |
| [Setup] Run Keywords Test Setup Execution AND Create VLAN ${vlan_id} |
| [Teardown] Delete VLAN ${vlan_id} |
| |
| Configure Network Settings On VLAN ${vlan_id} ${ip} ${netmask} |
| Get VLAN URI For IP ${vlan_id} ${ip} |
| |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['IP Address'] ["${ip}"] |
| |
| |
| Delete IP On VLAN Via REST |
| [Documentation] Delete IP on VLAN and verify it via REST and IPMI. |
| [Tags] Delete_IP_On_VLAN_Via_REST |
| [Setup] Run Keywords Test Setup Execution AND Create VLAN ${vlan_id} |
| [Teardown] Delete VLAN ${vlan_id} |
| |
| Configure Network Settings On VLAN ${vlan_id} ${ip} ${netmask} |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['IP Address'] ["${ip}"] |
| |
| ${vlan_ip_uri}= Get VLAN URI For IP ${vlan_id} ${ip} |
| Delete IP And Object ${ip} ${vlan_ip_uri} |
| |
| Get VLAN URI For IP ${vlan_id} ${ip} expected_result=error |
| |
| ${lan_config}= Get LAN Print Dict |
| Should Not Match ${lan_config['IP Address']} ${ip} |
| |
| |
| Delete VLAN When IP Is Configured Via REST |
| [Documentation] Delete IP on VLAN and verify using IPMI. |
| [Tags] Delete_VLAN_When_IP_Is_Configured_Via_REST |
| [Setup] Run Keywords Test Setup Execution AND Create VLAN ${vlan_id} |
| [Teardown] Delete VLAN ${vlan_id} |
| |
| Configure Network Settings On VLAN ${vlan_id} ${ip} ${netmask} |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['IP Address'] ["${ip}"] |
| Delete VLAN ${vlan_id} |
| |
| Verify Existence Of VLAN ${vlan_id} expected_result=error |
| |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['802.1q VLAN ID'] ["Disabled"] |
| |
| |
| Configure VLAN And Check Persistency On Reboot |
| [Documentation] Create VLAN ID & IP , reboot and verify. |
| [Tags] Configure_VLAN_And_Check_Persistency_On_Reboot |
| [Setup] Test Setup Execution |
| [Teardown] Delete VLAN ${vlan_id} |
| |
| Create VLAN ${vlan_id} |
| Configure Network Settings On VLAN ${vlan_id} ${ip} ${netmask} |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['IP Address'] ["${ip}"] |
| Valid Value lan_config['802.1q VLAN ID'] ["${vlan_id}"] |
| |
| Initiate BMC Reboot |
| |
| Verify Existence Of VLAN ${vlan_id} |
| Get VLAN URI For IP ${vlan_id} ${ip} |
| |
| ${lan_config}= Get LAN Print Dict |
| Valid Value lan_config['IP Address'] ["${ip}"] |
| Valid Value lan_config['802.1q VLAN ID'] ["${vlan_id}"] |
| |
| |
| *** Keywords *** |
| |
| |
| Test Setup Execution |
| [Documentation] Check and delete all previously created VLAN if any. |
| |
| ${lan_config}= Get LAN Print Dict |
| Return From Keyword If '${lan_config['802.1q VLAN ID']}' == 'Disabled' |
| |
| # Get all VLAN ID on interface eth0. |
| ${vlan_ids}= Get VLAN IDs |
| |
| ${initial_vlan_config}= Create List |
| Set Suite Variable ${initial_vlan_config} |
| |
| FOR ${vlan_id} IN @{vlan_ids} |
| ${vlan_records}= Read Properties |
| ... ${NETWORK_MANAGER}eth0_${vlan_id}${/}enumerate quiet=1 |
| ${vlan_record}= Filter Struct |
| ... ${vlan_records} [('Origin', '${static_network_resource}')] |
| |
| ${id}= Convert To Integer ${vlan_id} |
| Set Initial VLAN Config ${vlan_record} ${id} |
| END |
| Rprint Vars initial_vlan_config |
| |
| FOR ${vlan_id} IN @{vlan_ids} |
| Delete VLAN ${vlan_id} |
| END |
| |
| |
| Set Initial VLAN Config |
| [Documentation] Set suite level list of Initial VLAN Config. |
| [Arguments] ${vlan_record} ${id} |
| |
| # Description of argument(s): |
| # vlan_record Dictionary of IP configuration information of a VLAN. |
| # Example: |
| # /xyz/openbmc_project/network/eth0_55/ipv4/5fb2cfe6": { |
| # "Address": "x.x.x.x", |
| # "Gateway": "", |
| # "Origin": "xyz.openbmc_project.Network.IP.AddressOrigin.Static", |
| # "PrefixLength": 16, |
| # "Type": "xyz.openbmc_project.Network.IP.Protocol.IPv4"} |
| # |
| # id The VLAN ID corresponding to the IP Configuration records contained |
| # in the variable "vlan_record". |
| |
| ${uris}= Get Dictionary Keys ${vlan_record} |
| FOR ${uri} IN @{uris} |
| Append To List ${initial_vlan_config} ${id} ${vlan_record['${uri}']['Address']} |
| ... ${vlan_record['${uri}']['PrefixLength']} |
| END |
| Run Keyword If @{uris} == @{EMPTY} |
| ... Append To List ${initial_vlan_config} ${id} ${EMPTY} ${EMPTY} |
| |
| |
| Suite Teardown Execution |
| [Documentation] Restore VLAN configuration. |
| |
| ${length}= Get Length ${initial_vlan_config} |
| Return From Keyword If ${length} == ${0} |
| |
| ${previous_id}= Set Variable ${EMPTY} |
| FOR ${index} IN RANGE 0 ${length} 3 |
| |
| Run Keyword If '${initial_vlan_config[${index+1}]}' == '${EMPTY}' |
| ... Create VLAN ${initial_vlan_config[${index}]} |
| ... ELSE IF '${previous_id}' == '${initial_vlan_config[${index}]}' |
| ... Configure Network Settings On VLAN ${initial_vlan_config[${index}]} |
| ... ${initial_vlan_config[${index+1}]} ${initial_vlan_config[${index+2}]} |
| ... ELSE Run Keywords Create VLAN ${initial_vlan_config[${index}]} AND |
| ... Configure Network Settings On VLAN ${initial_vlan_config[${index}]} |
| ... ${initial_vlan_config[${index+1}]} ${initial_vlan_config[${index+2}]} |
| |
| ${previous_id}= Set Variable ${initial_vlan_config[${index}]} |
| END |
| |
| |
| Delete VLAN |
| [Documentation] Delete a VLAN. |
| [Arguments] ${id} ${interface}=eth0 |
| |
| # Description of argument(s): |
| # id The VLAN ID (e.g. '53'). |
| # interface The physical interface for the VLAN(e.g. 'eth0'). |
| |
| OpenBMC Delete Request ${NETWORK_MANAGER}${interface}_${id} |
| Sleep ${NETWORK_TIMEOUT}s |
| |
| |
| Create VLAN |
| [Documentation] Create a VLAN. |
| [Arguments] ${id} ${interface}=eth0 ${expected_result}=valid |
| |
| # Description of argument(s): |
| # id The VLAN ID (e.g. '53'). |
| # interface The physical interface for the VLAN(e.g. 'eth0'). |
| |
| @{data_vlan_id}= Create List ${interface} ${id} |
| ${data}= Create Dictionary data=@{data_vlan_id} |
| ${resp}= OpenBMC Post Request ${vlan_resource} data=${data} |
| ${resp.status_code}= Convert To String ${resp.status_code} |
| ${status}= Run Keyword And Return Status |
| ... Valid Value resp.status_code ["${HTTP_OK}"] |
| |
| Run Keyword If '${expected_result}' == 'error' |
| ... Should Be Equal ${status} ${False} |
| ... msg=Configuration of an invalid VLAN ID Failed. |
| ... ELSE |
| ... Should Be Equal ${status} ${True} |
| ... msg=Configuration of a valid VLAN ID Failed. |
| |
| Sleep ${NETWORK_TIMEOUT}s |
| |
| |
| Get VLAN IDs |
| [Documentation] Return all VLAN IDs. |
| |
| ${vlan_ids} ${stderr} ${rc}= BMC Execute Command |
| ... /sbin/ip addr | grep @eth0 | cut -f1 -d@ | cut -f2 -d. |
| ${vlan_ids}= Split String ${vlan_ids} |
| |
| [Return] @{vlan_ids} |
| |
| |
| Configure Network Settings On VLAN |
| [Documentation] Configure network settings. |
| [Arguments] ${id} ${ip_addr} ${prefix_len} ${gateway_ip}=${gateway} |
| ... ${expected_result}=valid ${interface}=eth0 |
| |
| # Description of argument(s): |
| # id The VLAN ID (e.g. '53'). |
| # ip_addr IP address of VLAN Interface. |
| # prefix_len Prefix length of VLAN Interface. |
| # gateway_ip Gateway IP address of VLAN Interface. |
| # expected_result Expected status of network setting configuration. |
| # interface Physical Interface on which the VLAN is defined. |
| |
| @{ip_parm_list}= Create List ${network_resource} |
| ... ${ip_addr} ${prefix_len} ${gateway_ip} |
| |
| ${data}= Create Dictionary data=@{ip_parm_list} |
| |
| Run Keyword And Ignore Error OpenBMC Post Request |
| ... ${NETWORK_MANAGER}${interface}_${id}/action/IP data=${data} |
| |
| # After any modification on network interface, BMC restarts network |
| # module, wait until it is reachable. Then wait 15 seconds for new |
| # configuration to be updated on BMC. |
| |
| Wait For Host To Ping ${OPENBMC_HOST} ${NETWORK_TIMEOUT} |
| ... ${NETWORK_RETRY_TIME} |
| Sleep ${NETWORK_TIMEOUT}s |
| |
| # Verify whether new IP address is populated on BMC system. |
| # It should not allow to configure invalid settings. |
| ${status}= Run Keyword And Return Status |
| ... Verify IP On BMC ${ip_addr} |
| |
| Run Keyword If '${expected_result}' == 'error' |
| ... Should Be Equal ${status} ${False} |
| ... msg=Configuration of invalid IP Failed. |
| ... ELSE |
| ... Should Be Equal ${status} ${True} |
| ... msg=Configuration of valid IP Failed. |
| |
| |
| Get VLAN URI For IP |
| [Documentation] Get and return the URI for a VLAN IP. |
| [Arguments] ${vlan_id} ${vlan_ip} ${expected_result}=valid |
| |
| # Description of argument(s): |
| # vlan_id The VLAN ID (e.g. '53'). |
| # vlan_ip The VLAN IP (e.g. 'x.x.x.x'). |
| |
| ${vlan_records}= Read Properties |
| ... ${NETWORK_MANAGER}eth0_${vlan_id}${/}enumerate quiet=1 |
| ${vlan_record}= Filter Struct ${vlan_records} [('Address', '${vlan_ip}')] |
| ${num_vlan_records}= Get Length ${vlan_record} |
| ${status}= Run Keyword And Return Status Should Be True ${num_vlan_records} > 0 |
| ... msg=Could not find a uri for vlan "${vlan_id}" with IP "${vlan_ip}". |
| |
| Run Keyword If '${expected_result}' == 'valid' |
| ... Should Be Equal ${status} ${True} |
| ... msg=VLAN IP URI Dosen't exist!. |
| ... ELSE |
| ... Should Be Equal ${status} ${False} |
| ... msg=VLAN IP URI exists!. |
| ${uris}= Get Dictionary Keys ${vlan_record} |
| Return From Keyword If @{uris} == @{EMPTY} |
| |
| [Return] ${uris[${0}]} |
| |
| |
| Verify Existence Of VLAN |
| [Documentation] Verify VLAN ID exists. |
| [Arguments] ${id} ${interface}=eth0 ${expected_result}=valid |
| |
| # Description of argument(s): |
| # id The VLAN ID (e.g. id:'53'). |
| # interface Physical Interface on which the VLAN is defined. |
| # expected_result Expected status to check existence or non-existence of VLAN. |
| |
| ${vlan_ids}= Get VLAN IDs |
| ${cli_status}= Run Keyword And Return Status |
| ... Valid List vlan_ids required_values=['${id}'] |
| |
| ${network_records}= Read Properties ${NETWORK_MANAGER} |
| ${rest_status}= Run Keyword And Return Status Valid List network_records |
| ... required_values=['${NETWORK_MANAGER}${interface}_${id}'] |
| |
| Should Be Equal ${rest_status} ${cli_status} |
| ... msg=REST and CLI Output are not the same. |
| Run Keyword If '${expected_result}' == 'valid' |
| ... Should Be Equal ${rest_status} ${True} |
| ... msg=VLAN ID Dosen't exist!. |
| ... ELSE |
| ... Should Be Equal ${rest_status} ${False} |
| ... msg=VLAN ID exists!. |