blob: 6212c6f5b85f119c706b83c6d3261b49102610bd [file] [log] [blame]
*** Settings ***
Documentation Test Suite for Supported Fan Modules.
Resource ../../lib/rest_client.robot
Resource ../../lib/bmc_redfish_resource.robot
Resource ../../lib/bmc_redfish_utils.robot
Resource ../../lib/openbmc_ffdc.robot
Resource ../../lib/resource.robot
Resource ../../lib/boot_utils.robot
Library ../../lib/gen_robot_valid.py
Library ../../lib/gen_robot_keyword.py
Suite Setup Suite Setup Execution
Suite Teardown Suite Teardown Execution
Test Setup Printn
Test Teardown Test Teardown Execution
*** Variables ***
@{VALID_MODE_VALUES} DEFAULT CUSTOM HEAVY_IO MAX_BASE_FAN_FLOOR
*** Test Cases ***
Verify Current Fan Thermal Mode
[Documentation] Check current thermal fan mode is a valid mode value.
[Tags] Verify_Current_Fan_Thermal_Mode
# Example:
# /xyz/openbmc_project/control/thermal/0
#
# Response code:200, Content: {
# "data": {
# "Current": "DEFAULT",
# "Supported": [
# "DEFAULT",
# "CUSTOM",
# "HEAVY_IO",
# "MAX_BASE_FAN_FLOOR"
# },
# },
# "message": "200 OK",
# "status": "ok"
# }
${current}= Read Attribute ${THERMAL_CONTROL_URI} Current
Rprint Vars current
Valid Value current valid_values=${VALID_MODE_VALUES}
Verify Supported Fan Thermal Modes Available
[Documentation] Check supported fan thermal modes are valid mode values.
[Tags] Verify_Supported_Fan_Thermal_Modes_Available
${supported}= Read Attribute ${THERMAL_CONTROL_URI} Supported
Rprint Vars supported
Valid List supported valid_values=${VALID_MODE_VALUES}
Verify Supported Fan Thermal Modes Switch At Standby
[Documentation] Check that supported modes are set successfully at standby.
[Tags] Verify_Supported_Fan_Thermal_Modes_Switch_At_Standby
[Template] Set and Verify Thermal Mode Switches
# pre_req_state thermal_mode_type
Off DEFAULT
Off CUSTOM
Off HEAVY_IO
Off MAX_BASE_FAN_FLOOR
Verify Supported Fan Thermal Modes Switch At Runtime
[Documentation] Check that supported modes are set successfully at runtime.
[Tags] Verify_Supported_Fan_Thermal_Modes_Switch_At_Runtime
[Template] Set and Verify Thermal Mode Switches
# pre_req_state thermal_mode
On DEFAULT
On CUSTOM
On HEAVY_IO
On MAX_BASE_FAN_FLOOR
Verify Supported Fan Thermal Mode Remains Set After Boot
[Documentation] Check that supported modes remain set at runtime.
[Tags] Verify_Supported_Fan_Thermal_Mode_Remains_Set_After_Boot
[Template] Set and Verify Thermal Mode After Boot
# pre_req_state thermal_mode_type
Off DEFAULT
Off CUSTOM
Off HEAVY_IO
Off MAX_BASE_FAN_FLOOR
*** Keywords ***
Set and Verify Thermal Mode Switches
[Documentation] Verify the thermal mode switches successfully at standby or runtime.
[Arguments] ${pre_req_state} ${thermal_mode}
# Description of Arguments(s):
# thermal_mode Read the supported thermal mode (e.g. "CUSTOM")
# pre_req_state Set the state of the host to Standby or Runtime (e.g. "Running")
Run Key U Redfish Power ${pre_req_state} \ stack_mode=skip \ quiet=1
Redfish.Login
${mode}= Redfish.Put ${THERMAL_CONTROL_URI}/attr/Current body={"data": "${thermal_mode}"}
${current}= Read Attribute ${THERMAL_CONTROL_URI} Current
Should Be Equal As Strings ${thermal_mode} ${current}
... msg=The thermal mode does not match the current fan mode.
Rprint Vars current
Set and Verify Thermal Mode After Boot
[Documentation] Verify the thermal mode remains set at runtime.
[Arguments] ${pre_req_state} ${thermal_mode}
Set and Verify Thermal Mode Switches ${pre_req_state} ${thermal_mode}
Run Key U Redfish Power On \ stack_mode=normal \ quiet=1
Redfish.Login
${current}= Read Attribute ${THERMAL_CONTROL_URI} Current
Should Be Equal As Strings ${thermal_mode} ${current}
... msg=The current thermal fan mode switched successfully.
Rprint Vars current
Suite Teardown Execution
[Documentation] Do the post suite teardown.
Redfish.Logout
Suite Setup Execution
[Documentation] Do test case setup tasks.
Printn
Redfish.Login
Test Teardown Execution
[Documentation] Do the post test teardown.
FFDC On Test Case Fail