| *** Settings *** |
| |
| Documentation Operational check of fans with OS booted. |
| |
| # Test Parameters: |
| # OPENBMC_HOST The BMC host name or IP address. |
| # OPENBMC_USERNAME The userID to login to the BMC as. |
| # OPENBMC_PASSWORD The password for OPENBMC_USERNAME. |
| # |
| # Approximate run time: 18 minutes. |
| |
| Resource ../syslib/utils_os.robot |
| Resource ../lib/logging_utils.robot |
| Resource ../lib/utils.robot |
| Resource ../lib/fan_utils.robot |
| Library ../syslib/utils_keywords.py |
| Library OperatingSystem |
| |
| Suite Setup Suite Setup Execution |
| Test Teardown Test Teardown Execution |
| |
| |
| *** Test Cases *** |
| |
| |
| Check Number Of Fans With Power On |
| [Documentation] Verify system has the minimum number of fans. |
| [Tags] Check_Number_Of_Fans_With_Power_On |
| |
| # Determine if system is water cooled. |
| ${water_cooled}= Is Water Cooled |
| Rprint Vars water_cooled |
| |
| Verify Minimum Number Of Fans With Cooling Type ${number_of_fans} |
| ... ${water_cooled} |
| |
| |
| Check Number Of Fan Monitors With Power On |
| [Documentation] Verify monitors are present when power on. |
| [Tags] Check_Number_Of_Fan_Monitors_With_Power_On |
| |
| Verify Fan Monitors With State On |
| |
| |
| Check Fans Running At Target Speed |
| [Documentation] Verify fans are running at or near target speed. |
| [Tags] Check_Fans_Running_At_Target_Speed |
| |
| # Set the speed tolerance criteria. |
| # A tolerance value of .15 means that the fan's speed should be |
| # within 15% of its set target speed. Fans may be accelerating |
| # or decelerating to meet a new target, so allow .10 extra. |
| ${tolerance}= Set Variable .25 |
| Rpvars tolerance |
| |
| Verify Fan Speed ${tolerance} ${fan_names} |
| |
| |
| Check Fan Manual Control |
| [Documentation] Check direct control of fans. |
| [Tags] Check_Fan_Manual_Control |
| |
| # The maximum target speed. |
| ${max_fan_target_setting}= Set Variable ${10500} |
| |
| # Speed criteria for passing, which is 85% of max_fan_target_setting. |
| ${min_speed}= Set Variable ${8925} |
| |
| # Time allowed for the fan daemon to take control and then return |
| # the fans to normal speed. |
| ${minutes_to_stabilize}= Set Variable 4 |
| |
| Verify Direct Fan Control |
| ... ${max_fan_target_setting} ${min_speed} ${minutes_to_stabilize} |
| ... ${number_of_fans} ${fan_names} |
| |
| |
| Check Fan Speed Increase When One Disabled |
| [Documentation] Verify that the speed of working fans increase when |
| ... one fan is disabled. |
| [Tags] Check_Fan_Speed_Increase_When_One_Disabled |
| # A non-functional fan should cause an error log and |
| # an enclosure LED will light. The other fans should speed up. |
| |
| Verify Fan Speed Increase ${fan_names} |
| |
| |
| Check System Shutdown Due To Fans |
| [Documentation] Shut down when not enough fans. |
| [Tags] Check_System_Shutdown_Due_To_Fans |
| |
| Verify System Shutdown Due To Fans ${fan_names} |
| |
| |
| *** Keywords *** |
| |
| |
| Suite Setup Execution |
| [Documentation] Do the pre-test setup. |
| |
| REST Power On stack_mode=skip |
| |
| ${number_of_fans} ${fan_names}= Get Fan Count And Names |
| Printn |
| Rprint Vars number_of_fans fan_names |
| Set Suite Variable ${fan_names} children=true |
| Set Suite Variable ${number_of_fans} children=true |
| |
| Reset Fans ${fan_names} |
| Run Key U Sleep \ 15s |
| Delete All Error Logs |
| Set System LED State front_fault Off |
| Set System LED State rear_fault Off |
| |
| |
| Test Teardown Execution |
| [Documentation] Do the post-test teardown. |
| |
| FFDC On Test Case Fail |
| Reset Fans ${fan_names} |
| Run Key U Sleep \ 15s |
| Delete All Error Logs |
| Set System LED State front_fault Off |
| Set System LED State rear_fault Off |