blob: d97e15df6e954d1f8b9bb268326086b099354000 [file] [log] [blame]
*** Settings ***
Documentation Module to test IPMI network functionality.
Resource ../lib/ipmi_client.robot
Resource ../lib/openbmc_ffdc.robot
Resource ../lib/bmc_network_utils.robot
Resource ../lib/boot_utils.robot
Library ../lib/ipmi_utils.py
Library ../lib/gen_robot_valid.py
Library ../lib/var_funcs.py
Library ../lib/bmc_network_utils.py
Suite Setup Suite Setup Execution
Suite Teardown Redfish.Logout
Test Setup Printn
Test Teardown Test Teardown Execution
Force Tags IPMI_Network_Config
*** Variables ***
${vlan_id_for_ipmi} ${10}
@{vlan_ids} ${20} ${30}
${interface} eth0
${ip} 10.0.0.1
${initial_lan_config} &{EMPTY}
${vlan_resource} ${NETWORK_MANAGER}action/VLAN
${netmask} ${24}
${gateway} 0.0.0.0
${vlan_id_for_rest} ${30}
*** Test Cases ***
Verify IPMI Inband Network Configuration
[Documentation] Verify BMC network configuration via inband IPMI.
[Tags] Verify_IPMI_Inband_Network_Configuration
[Teardown] Run Keywords Restore Configuration AND FFDC On Test Case Fail
Redfish Power On
Set IPMI Inband Network Configuration ${STATIC_IP} ${NETMASK} ${GATEWAY}
Sleep 10
${lan_print_output}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_print_output['IP Address'] ["${STATIC_IP}"]
Valid Value lan_print_output['Subnet Mask'] ["${NETMASK}"]
Valid Value lan_print_output['Default Gateway IP'] ["${GATEWAY}"]
Disable VLAN Via IPMI When Multiple VLAN Exist On BMC
[Documentation] Disable VLAN Via IPMI When Multiple VLAN Exist On BMC.
[Tags] Disable_VLAN_Via_IPMI_When_Multiple_VLAN_Exist_On_BMC
FOR ${vlan_id} IN @{vlan_ids}
Create VLAN ${vlan_id}
END
Create VLAN Via IPMI off
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_config['802.1q VLAN ID'] ['Disabled']
Configure IP On VLAN Via IPMI
[Documentation] Configure IP On VLAN Via IPMI.
[Tags] Configure_IP_On_VLAN_Via_IPMI
Create VLAN Via IPMI ${vlan_id_for_ipmi}
Run Inband IPMI Standard Command
... lan set ${CHANNEL_NUMBER} ipaddr ${ip} login_host=${0}
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}']
Valid Value lan_config['IP Address'] ["${ip}"]
Create VLAN Via IPMI When LAN And VLAN Exist On BMC
[Documentation] Create VLAN Via IPMI When LAN And VLAN Exist On BMC.
[Tags] Create_VLAN_Via_IPMI_When_LAN_And_VLAN_Exist_On_BMC
[Setup] Create VLAN ${vlan_id_for_rest}
Create VLAN Via IPMI ${vlan_id_for_ipmi}
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}']
Create VLAN Via IPMI And Verify
[Documentation] Create and verify VLAN via IPMI.
[Tags] Create_VLAN_Via_IPMI_And_Verify
Create VLAN Via IPMI ${vlan_id_for_ipmi}
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}']
Valid Value lan_config['IP Address'] ['${ip_address}']
Valid Value lan_config['Subnet Mask'] ['${subnet_mask}']
Test Disabling Of VLAN Via IPMI
[Documentation] Disable VLAN and verify via IPMI.
[Tags] Test_Disabling_Of_VLAN_Via_IPMI
Create VLAN Via IPMI ${vlan_id_for_ipmi}
Create VLAN Via IPMI off
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_config['802.1q VLAN ID'] ['Disabled']
Create VLAN When LAN And VLAN Exist With IP Address Configured
[Documentation] Create VLAN when LAN and VLAN exist with IP address configured.
[Tags] Create_VLAN_When_LAN_And_VLAN_Exist_With_IP_Address_Configured
[Setup] Run Keywords Create VLAN ${vlan_id_for_rest} interface=${interface}
... AND Configure Network Settings On VLAN ${vlan_id_for_rest} ${ip}
... ${netmask} ${gateway} interface=${interface}
Create VLAN Via IPMI ${vlan_id_for_ipmi}
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id_for_ipmi}']
Valid Value lan_config['IP Address'] ['${ip}']
Create Multiple VLANs Via IPMI And Verify
[Documentation] Create multiple VLANs through IPMI.
[Tags] Create_Multiple_VLANs_Via_IPMI_And_Verify
FOR ${vlan_id} IN @{vlan_ids}
Create VLAN Via IPMI ${vlan_id}
${lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
# Validate VLAN creation.
Valid Value lan_config['802.1q VLAN ID'] ['${vlan_id}']
# Validate existing IP address.
Valid Value lan_config['IP Address'] ['${ip_address}']
# Validate existing subnet mask.
Valid Value lan_config['Subnet Mask'] ['${subnet_mask}']
END
*** Keywords ***
Create VLAN Via IPMI
[Documentation] Create VLAN via inband IPMI command.
[Arguments] ${vlan_id} ${channel_number}=${CHANNEL_NUMBER}
# Description of argument(s):
# vlan_id The VLAN ID (e.g. '10').
Run Inband IPMI Standard Command
... lan set ${channel_number} vlan id ${vlan_id} login_host=${0}
Set IPMI Inband Network Configuration
[Documentation] Run sequence of standard IPMI command in-band and set
... the IP configuration.
[Arguments] ${ip} ${netmask} ${gateway} ${login}=${1}
# Description of argument(s):
# ip The IP address to be set using ipmitool-inband.
# netmask The Netmask to be set using ipmitool-inband.
# gateway The Gateway address to be set using ipmitool-inband.
Run Inband IPMI Standard Command
... lan set ${CHANNEL_NUMBER} ipsrc static login_host=${login}
Run Inband IPMI Standard Command
... lan set ${CHANNEL_NUMBER} ipaddr ${ip} login_host=${0}
Run Inband IPMI Standard Command
... lan set ${CHANNEL_NUMBER} netmask ${netmask} login_host=${0}
Run Inband IPMI Standard Command
... lan set ${CHANNEL_NUMBER} defgw ipaddr ${gateway} login_host=${0}
Restore Configuration
[Documentation] Restore the configuration to its pre-test state.
${length}= Get Length ${initial_lan_config}
Return From Keyword If ${length} == ${0}
Set IPMI Inband Network Configuration ${ip_address} ${subnet_mask}
... ${initial_lan_config['Default Gateway IP']} login=${0}
Suite Setup Execution
[Documentation] Suite Setup Execution.
Redfish.Login
${initial_lan_config}= Get LAN Print Dict ${CHANNEL_NUMBER} ipmi_cmd_type=inband
Set Suite Variable ${initial_lan_config}
Run Inband IPMI Standard Command
... lan set ${CHANNEL_NUMBER} ipsrc static login_host=${1}
${host_name} ${ip_address}= Get Host Name IP host=${OPENBMC_HOST}
Set Suite Variable ${ip_address}
@{network_configurations}= Get Network Configuration
FOR ${network_configuration} IN @{network_configurations}
Run Keyword If '${network_configuration['Address']}' == '${ip_address}'
... Run Keywords Set Suite Variable ${subnet_mask} ${network_configuration['SubnetMask']} AND
... Exit For Loop
END
Test Teardown Execution
[Documentation] Test Teardown Execution.
FFDC On Test Case Fail
Create VLAN Via IPMI off
Restore Configuration