blob: d2a121f1751362ae032a24df23284db84de6cb96 [file] [log] [blame]
# https://github.com/openbmc/openbmc-test-automation/issues/822
--exclude Verify_Minimal_Memory_Buffer_Inventory
--exclude Verify_Minimal_Main_Planar_Inventory
--exclude Verify_Minimal_System_Inventory
# NA test case for Witherspoon
--exclude io_board_Present
--exclude io_board_Fault
# System LED test cases which are NA for Witherspoon system.
--exclude Test_Heartbeat_LED_And_Verify_Via_REST
--exclude Test_Beep_LED_And_Verify_Via_REST
--exclude Test_Identify_LED_And_Verify_Via_REST
# NXDMAENG UE error injection is not available in latest p9dd1ffdcv104.xlsm
--exclude Verify_Unrecoverable_Callout_Handling_For_NXDMAENG
# NA test case with nginx support.
--exclude Test_Non_SSL_Connection_To_Port_80
--exclude Test_Non_SSL_Connection_To_Port_443
# MRW changes required for this to work.
--exclude Test_GPU_SDR_Info_At_Power_On
# Core dump is disabled.
--exclude Verify_Core_Dump_Size
# Skip org code update.
--exclude Initiate_Code_Update_BMC
--exclude BIOS_Code_Update
--exclude Redfish_Image_Upload
--exclude Bmc_Code_Update
--exclude Redfish_Host_Code_Update
--exclude BMC_Update_Recoverable_Error
--exclude Host_Update_Recoverable_Error
--exclude BMC_Multi_Code_Update
--exclude Host_Multi_Code_Update
--exclude Verify_IPMI_Disable_Policy_Post_BMC_Code_Update
# Others NA tests.
--exclude Run_Keyword_Pgm
# Factory reset must not run in CT.
--exclude Factory_Reset
--exclude Full_Suite_Regression
--exclude AC_Cycles
--exclude Network_Nping
# Multiple runs only needed for stability.
--exclude Run_Multiple_Power_Cycle
--exclude Run_Multiple_BMC_Reset_Via_REST
--exclude Run_Multiple_BMC_Reset_Via_Reboot
--exclude General_boot_testing
--exclude SLP_Service_Test
--exclude Check_Network_Latency
# Configure invalid IP address use cases.
--exclude Configure_Broadcast_IP
--exclude Configure_Multicast_IP
--exclude Configure_Loopback_IP
--exclude Configure_Network_ID
# Invalid gateway address configuration.
--exclude Configure_Broadcast_IP_For_Gateway
--exclude Configure_Loopback_IP_For_Gateway
--exclude Configure_Multicast_IP_For_Gateway
--exclude Configure_Network_ID_For_Gateway
--exclude Verify_Network_Interface_Recovery
# Skipping RAS test cases
--exclude Host_RAS
# Skip multi threading test causing XML parser failure.
--exclude Stress_BMC_REST_Server
--exclude Stress_BMC_SSH_Server
--exclude Stress_BMC_IPMI_Server
# Applicable only for master build.
--exclude Verify_eSEL_Description_And_EntryID_Using_REST
# Needs fix and improvement.
--exclude Test_SBE_Side_Switch
# IPMI disable and enable use cases.
--exclude Verify_Disabling_And_Enabling_IPMI_Via_Host
--exclude Verify_Disabling_IPMI_Via_OOB_IPMI
--exclude Verify_IPMI_Disable_Persistency_After_BMC_Reboot
# Remote logging
--exclude Verify_BMC_Journald_Contains_No_Credential_Data
# Non bmcweb certificate.
--exclude Certificate