blob: e922ac4aabbf1d03fbdd9b0606e8a0bbadd40abd [file] [log] [blame]
Marissa Garzad76b1422019-09-13 16:31:54 -05001*** Settings ***
2Documentation Get the system power supply voltage readings.
3
4Resource ../../lib/bmc_redfish_resource.robot
5Resource ../../lib/bmc_redfish_utils.robot
6Resource ../../lib/openbmc_ffdc.robot
7Library ../../lib/gen_robot_valid.py
8
9Suite Setup Suite Setup Execution
10Suite Teardown Suite Teardown Execution
11Test Setup Printn
12Test Teardown Test Teardown Execution
13
14
15*** Test Cases ***
16
17Verify Power Control Consumed Watts
18 [Documentation] Verify there are no invalid power control consumed watt records.
19 [Tags] Verify_Power_Control_Consumed_Watts
20 [Template] Verify Power Metric Records
21
22 # record_type redfish_uri reading_type
23 PowerControl ${REDFISH_CHASSIS_POWER_URI} PowerConsumedWatts
24
25
26*** Keywords ***
27
28Verify Power Metric Records
29 [Documentation] Verify the power metric records.
30 [Arguments] ${record_type} ${redfish_uri} ${reading_type}
31
32 # Description of Arguments(s):
33 # record_type The sensor record type (e.g. "PowerControl")
34 # redfish_uri The power supply URI (e.g. /redfish/v1/Chassis/chassis/Power)
35 # reading_type The power metric readings (e.g. "PowerConsumedWatts")
36
37 Verify Valid Records ${record_type} ${redfish_uri} ${reading_type}
38
39 ${records}= Redfish.Get Attribute ${redfish_uri} ${record_type}
40
41 ${invalid_records}= Evaluate
42 ... [x for x in ${records} if not x['${reading_type}'] <= x['PowerMetrics']['MaxConsumedWatts']]
43
44 Valid Length invalid_records max_length=0
45
46
47Suite Teardown Execution
48 [Documentation] Do the post suite teardown.
49
50 Redfish.Logout
51
52
53Suite Setup Execution
54 [Documentation] Do test case setup tasks.
55
56 Printn
57 Redfish Power On stack_mode=skip
58 Redfish.Login
59
60
61Test Teardown Execution
62 [Documentation] Do the post test teardown.
63