blob: 7d7fdd25bd1a26907b71fe8d54ebe35822c5ca5f [file] [log] [blame]
Prashanth Katti884ee062017-03-16 05:05:03 -05001*** Settings ***
2Documentation This program performs Factory data reset.
3
4Resource ../lib/ipmi_client.robot
5Resource ../lib/utils.robot
6Resource ../lib/connection_client.robot
7Resource ../lib/oem/ibm/serial_console_client.robot
8Library OperatingSystem
9
10Suite Setup Validate Setup
11Suite Teardown Close All Connections
12
13*** Test Cases ***
14
15Verify Factory Reset
16 [Documentation] Factory reset the system and verify if BMC is online.
17 [Tags] Verify_Factory_Reset
18
19 # Factory reset erases user config settings which incldes IP, netmask
20 # gateway and route. Before running this test we are checking all these
21 # settings and checking whether ping works with BMC host.
22 # If factory reset is successful, ping to BMC host should fail as
23 # IP address is erased and comes up with zero_conf.
24
25 Erase All Settings
26 ${status}= Run Keyword And Return Status Ping Host ${OPENBMC_HOST}
27 Should Be Equal ${status} False msg=Factory reset failed.
28
29Revert to Initial Setup And Verify
30 [Documentation] Revert to old setup.
31 [Tags] Revert_to_Initial_Setup_And_Verify
32
33 # This test case restores old settings Viz IP address, netmask, gateway
34 # and route. Restoring is done through serial port console.
35 # If reverting to initial setup is successful, ping to BMC
36 # host should pass.
37
38 Configure Initial Settings
39 Ping Host ${OPENBMC_HOST}
40
41*** Keywords ***
42
43Validate Setup
44 [Documentation] Validate setup.
45
46 Open Connection And Log In
47
48 # Check whether gateway IP is reachable.
49 Ping Host ${GW_IP}
50 Should Not Be Empty ${NET_MASK} msg=Netmask not provided.
51
52 # Check whether serial console IP is reachable and responding
53 # to telnet command.
54 Open Telnet Connection to BMC Serial Console
55
56Erase All Settings
57 [Documentation] Factory reset the system.
58
59 Run Dbus IPMI Raw Command 0x32 0xBA 00 00
60 Run Dbus IPMI Raw Command 0x32 0x66