George Keishing | fc3096a | 2022-07-12 14:55:37 -0500 | [diff] [blame] | 1 | *** Settings *** |
| 2 | Documentation Redfish test to switch image sides and boot. |
| 3 | |
| 4 | Resource ../../lib/resource.robot |
| 5 | Resource ../../lib/bmc_redfish_resource.robot |
| 6 | Resource ../../lib/openbmc_ffdc.robot |
| 7 | Resource ../../lib/redfish_code_update_utils.robot |
| 8 | Library ../../lib/tftp_update_utils.py |
| 9 | |
| 10 | Suite Setup Suite Setup Execution |
George Keishing | dbd7afb | 2022-08-11 08:34:20 -0500 | [diff] [blame] | 11 | Suite Teardown Run Keyword And Ignore Error Redfish.Logout |
George Keishing | fc3096a | 2022-07-12 14:55:37 -0500 | [diff] [blame] | 12 | Test Teardown FFDC On Test Case Fail |
| 13 | |
George Keishing | 504a371 | 2022-07-22 09:41:28 -0500 | [diff] [blame] | 14 | Force Tags Test_BMC_Image_Switch |
| 15 | |
George Keishing | fc3096a | 2022-07-12 14:55:37 -0500 | [diff] [blame] | 16 | *** Variables *** |
| 17 | |
| 18 | # Switch iteration count. By default it does only 2 switch. |
| 19 | # User can input -v LOOP_COUNT:n to drive the switch back and forth for |
| 20 | # nth iteration. |
| 21 | ${LOOP_COUNT} ${2} |
| 22 | |
| 23 | *** Test Cases *** |
| 24 | |
| 25 | Test Firmware Image Switch Without Powering Host |
| 26 | [Documentation] Switch image at host powered off. |
| 27 | [Tags] Test_Firmware_Image_Switch_Without_Powering_Host |
| 28 | [Template] Firmware Switch Loop |
| 29 | |
| 30 | # iteration power_on |
| 31 | ${LOOP_COUNT} NO |
| 32 | |
| 33 | |
| 34 | Test Firmware Image Switch And Power On Host |
| 35 | [Documentation] Switch image and power on host and verify that it boots. |
| 36 | [Tags] Test_Firmware_Image_Switch_And_Power_On_Host |
| 37 | [Template] Firmware Switch Loop |
| 38 | |
| 39 | # iteration power_on |
| 40 | ${LOOP_COUNT} YES |
| 41 | |
| 42 | |
| 43 | *** Keywords *** |
| 44 | |
| 45 | Firmware Switch Loop |
| 46 | [Documentation] Wrapper keyword for iteration for firmware side switch. |
| 47 | [Arguments] ${iteration} ${power_on} |
| 48 | |
| 49 | # Description of argument(s): |
| 50 | # iteration Number of switch it needs to perform. |
| 51 | # power_on If YES, boot the system post firmware image switch, |
| 52 | # if NO, do not perform any poweron operation. |
| 53 | |
| 54 | FOR ${count} IN RANGE 0 ${iteration} |
| 55 | Log To Console LOOP_COUNT:${count} execution. |
| 56 | Redfish BMC Switch Firmware Side |
| 57 | |
| 58 | Continue For Loop If '${power_on}' == 'NO' |
| 59 | |
| 60 | Log To Console Power on requested, issuing power on. |
| 61 | Redfish Power On |
| 62 | |
| 63 | # Power Off for next iteration. Firmware image switch ideally needs to be |
| 64 | # to be executed when Host is powered off. |
| 65 | Log To Console Power off requested, issuing power off. |
| 66 | Redfish Power Off |
| 67 | END |
| 68 | |
| 69 | |
| 70 | Suite Setup Execution |
| 71 | [Documentation] Do the suite setup. |
| 72 | |
| 73 | Redfish.Login |
| 74 | Run Keyword And Ignore Error Redfish Purge Event Log |
| 75 | Redfish Power Off stack_mode=skip |
| 76 | |
| 77 | |
| 78 | Redfish BMC Switch Firmware Side |
| 79 | [Documentation] Switch back up image to running and verify. |
| 80 | [Tags] Redfish_BMC_Switch_Firmware_Side |
| 81 | |
| 82 | # fw_inv_dict: |
| 83 | # [19a3ef3e]: |
| 84 | # [image_type]: BMC image |
| 85 | # [image_id]: 19a3ef3e |
| 86 | # [functional]: True |
| 87 | # [version]: 2.12.0-dev-1440-g8dada0a1a |
| 88 | # [62d16947]: |
| 89 | # [image_type]: BMC image |
| 90 | # [image_id]: 62d16947 |
| 91 | # [functional]: False |
| 92 | # [version]: 2.12.0-dev-1441-g8deadbeef |
| 93 | ${fw_inv_dict}= Get Software Inventory State |
| 94 | Rprint Vars fw_inv_dict |
| 95 | |
| 96 | # Get the backup firmware version for reference. |
| 97 | FOR ${id} IN @{fw_inv_dict.keys()} |
| 98 | Continue For Loop If '${fw_inv_dict['${id}']['functional']}' == 'True' |
| 99 | # Find the non functional id and fetch the version. |
| 100 | ${image_version}= Set Variable ${fw_inv_dict['${id}']['version']} |
| 101 | END |
| 102 | |
| 103 | Log To Console Backup firmware version: ${image_version} |
| 104 | |
| 105 | Switch Firmware Side ${image_version} |
| 106 | |
| 107 | Match BMC Release And Redifsh Firmware Version |
| 108 | Log To Console The backup firmware image ${image_version} is now functional. |
| 109 | |
| 110 | |
| 111 | Match BMC Release And Redifsh Firmware Version |
| 112 | [Documentation] The /etc/os-release vs Redfish FirmwareVersion attribute value from |
| 113 | ... /redfish/v1/Managers/bmc should match. |
| 114 | |
| 115 | # Python module: get_bmc_release_info() |
| 116 | ${bmc_release_info}= utils.Get BMC Release Info |
| 117 | ${bmc_release}= Set Variable ${bmc_release_info['version_id']} |
| 118 | Rprint Vars bmc_release |
| 119 | |
| 120 | ${firmware_version}= Redfish.Get Attribute /redfish/v1/Managers/bmc FirmwareVersion |
| 121 | Rprint Vars firmware_version |
| 122 | |
| 123 | Should Be Equal As Strings ${bmc_release} ${firmware_version} |
| 124 | ... msg=${bmc_release} does not match redfish version ${firmware_version} |
| 125 | |
| 126 | |
| 127 | Switch Firmware Side |
| 128 | [Documentation] Set the backup firmware to functional and verify after BMC rebooted. |
| 129 | [Arguments] ${image_version} |
| 130 | |
| 131 | # Description of argument(s): |
| 132 | # image_version Version of image. |
| 133 | |
| 134 | ${state}= Get Pre Reboot State |
| 135 | |
| 136 | Print Timen Switch to back up and rebooting. |
| 137 | Switch Backup Firmware Image To Functional |
| 138 | Wait For Reboot start_boot_seconds=${state['epoch_seconds']} |
| 139 | Print Timen Switch to back up completed. |
| 140 | |
| 141 | # Check if the BMC version after rebooted is the same version asked to switch. |
| 142 | ${firmware_version}= Redfish.Get Attribute /redfish/v1/Managers/bmc FirmwareVersion |
| 143 | Should Be Equal As Strings ${image_version} ${firmware_version} |
| 144 | ... msg=${image_version} does not match redfish version ${firmware_version} |