Steven Sombar | 6b28014 | 2018-02-12 10:45:13 -0600 | [diff] [blame] | 1 | *** Settings *** |
| 2 | Documentation Utilities for fan tests. |
| 3 | |
| 4 | Library ../lib/bmc_ssh_utils.py |
| 5 | Variables ../data/variables.py |
| 6 | |
| 7 | *** Keywords *** |
| 8 | |
| 9 | |
| 10 | Is Water Cooled |
| 11 | [Documentation] Return 1 if system is water cooled, 0 othersise. |
| 12 | |
| 13 | ${water_cooled}= Read Attribute |
| 14 | ... ${HOST_INVENTORY_URI}/system/chassis WaterCooled |
| 15 | [Return] ${water_cooled} |
| 16 | |
| 17 | |
| 18 | Get Number Of Fans |
| 19 | [Documentation] Get the number of fans currently present in inventory. |
| 20 | |
| 21 | ${num_fans} Set Variable ${0} |
| 22 | ${fan_uris}= Get Endpoint Paths ${HOST_INVENTORY_URI}/system fan |
| 23 | |
| 24 | : FOR ${fan_uri} IN @{fan_uris} |
| 25 | \ ${fan_record}= Read Properties ${fan_uri} |
| 26 | \ Continue For Loop If ${fan_record['Present']} != 1 |
| 27 | \ ${num_fans}= Set Variable ${num_fans+1} |
| 28 | [Return] ${num_fans} |
| 29 | |
| 30 | |
| 31 | Verify Minimum Number Of Fans With Cooling Type |
| 32 | [Documentation] Verify minimum number of fans. |
| 33 | [Arguments] ${water_cooled} |
| 34 | |
| 35 | # Description of argument(s): |
| 36 | # water_cooled The value 1 if the system is water cooled, |
| 37 | # the value 0 if air cooled. |
| 38 | |
| 39 | # For a water cooled system. |
| 40 | ${min_fans_water}= Set Variable 2 |
| 41 | |
| 42 | # For an air cooled system. |
| 43 | ${min_fans_air}= Set Variable 3 |
| 44 | |
| 45 | ${num_fans}= Get Number Of Fans |
| 46 | |
| 47 | Rprintn |
| 48 | Rpvars water_cooled num_fans |
| 49 | |
| 50 | # If water cooled must have at least min_fans_water fans, otherwise |
| 51 | # issue Fatal Error and terminate testing. |
| 52 | Run Keyword If ${water_cooled} == 1 and ${num_fans} < ${min_fans_water} |
| 53 | ... Fatal Error |
| 54 | ... msg=Water cooled but less than ${min_fans_water} fans present. |
| 55 | |
| 56 | # If air cooled must have at least min_fans_air fans. |
| 57 | Run Keyword If ${water_cooled} == 0 and ${num_fans} < ${min_fans_air} |
| 58 | ... Fatal Error |
| 59 | ... msg=Air cooled but less than ${min_fans_air} fans present. |
| 60 | |
| 61 | |
| 62 | Verify Fan Monitors With State |
| 63 | [Documentation] Verify fan monitor daemons in the system state. |
| 64 | # The number of monitoring daemons is dependent upon the system |
| 65 | # power state. If power is off there should be 0, if power |
| 66 | # is on there should be several. |
| 67 | [Arguments] ${power_state} |
| 68 | |
| 69 | # Description of argument(s): |
| 70 | # power_state Power staet of the system, either "On" or "Off" |
| 71 | |
| 72 | ${cmd}= Catenate systemctl list-units | grep phosphor-fan | wc -l |
| 73 | ${num_fan_daemons} ${stderr} ${rc}= BMC Execute Command ${cmd} |
| 74 | |
| 75 | Rpvars power_state num_fan_daemons |
| 76 | |
| 77 | # Fail if system is On and there are no fan monitors. |
| 78 | Run Keyword If '${power_state}' == 'On' and ${num_fan_daemons} == 0 |
| 79 | ... Fail msg=No phosphor-fan monitors found at power on. |
| 80 | |
| 81 | # Fail if system is Off and the fan monitors are present. |
| 82 | Run Keyword If '${power_state}' == 'Off' and ${num_fan_daemons} != 0 |
| 83 | ... Fail msg=Phosphor-fan monitors found at power off. |