Alphabetize lists

Change-Id: I068940d3f400cae26d94dff7f5b29bd596c2a6f6
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
diff --git a/meta-phosphor/classes/obmc-phosphor-image.bbclass b/meta-phosphor/classes/obmc-phosphor-image.bbclass
index c2455b8..d993bb1 100644
--- a/meta-phosphor/classes/obmc-phosphor-image.bbclass
+++ b/meta-phosphor/classes/obmc-phosphor-image.bbclass
@@ -2,56 +2,57 @@
 
 # Additional IMAGE_FEATURES available with Phosphor OpenBMC:
 #
-# - obmc-phosphor-fan-mgmt            - Phosphor OpenBMC fan management
-# - obmc-phosphor-chassis-mgmt        - Phosphor OpenBMC chassis management
-# - obmc-phosphor-sensor-mgmt         - Phosphor OpenBMC sensor management
-# - obmc-phosphor-flash-mgmt          - Phosphor OpenBMC flash management
-# - obmc-phosphor-event-mgmt          - Phosphor OpenBMC event management
-# - obmc-phosphor-user-mgmt           - Phosphor OpenBMC user management
+# - obmc-bmc-state-mgmt               - OpenBMC BMC state management
+# - obmc-chassis-mgmt                 - OpenBMC chassis management
+# - obmc-chassis-state-mgmt           - OpenBMC chassis state management
+# - obmc-event-mgmt                   - OpenBMC event management
+# - obmc-fan-mgmt                     - OpenBMC fan management
+# - obmc-flash-mgmt                   - OpenBMC flash management
+# - obmc-host-ctl                     - OpenBMC host control
+# - obmc-host-ipmi                    - OpenBMC host IPMI
+# - obmc-host-state-mgmt              - OpenBMC host state management
+# - obmc-logging-mgmt                 - OpenBMC logging management
+# - obmc-sensor-mgmt                  - OpenBMC sensor management
 # - obmc-settings-mgmt                - OpenBMC settings management
-# - obmc-phosphor-system-mgmt         - Phosphor OpenBMC system management
-# - obmc-host-ipmi                    - OpenBMC Host IPMI
-# - obmc-logging                      - OpenBMC logging management
-# - obmc-host-state-mgmt              - OpenBMC Host State Management
-# - obmc-chassis-state-mgmt           - OpenBMC Chassis State Management
-# - obmc-bmc-state-mgmt               - OpenBMC BMC State Management
+# - obmc-system-mgmt                  - OpenBMC system management
+# - obmc-user-mgmt                    - OpenBMC user management
 
 inherit core-image
 inherit obmc-phosphor-license
 inherit obmc-phosphor-utils
 
-FEATURE_PACKAGES_obmc-fan-mgmt ?= "${@cf_enabled('obmc-phosphor-fan-mgmt', 'virtual-obmc-fan-mgmt', d)}"
+FEATURE_PACKAGES_obmc-bmc-state-mgmt ?= "${@cf_enabled('obmc-bmc-state-mgmt', 'virtual-obmc-bmc-state-mgmt', d)}"
 FEATURE_PACKAGES_obmc-chassis-mgmt ?= "${@cf_enabled('obmc-phosphor-chassis-mgmt', 'virtual-obmc-chassis-mgmt', d)}"
-FEATURE_PACKAGES_obmc-sensor-mgmt ?= "${@cf_enabled('obmc-phosphor-sensor-mgmt', 'virtual-obmc-sensor-mgmt', d)}"
-FEATURE_PACKAGES_obmc-flash-mgmt ?= "${@cf_enabled('obmc-phosphor-flash-mgmt', 'virtual-obmc-flash-mgmt', d)}"
+FEATURE_PACKAGES_obmc-chassis-state-mgmt ?= "${@cf_enabled('obmc-chassis-state-mgmt', 'virtual-obmc-chassis-state-mgmt', d)}"
 FEATURE_PACKAGES_obmc-event-mgmt ?= "${@df_enabled('obmc-phosphor-event-mgmt', 'virtual-obmc-event-mgmt', d)}"
-FEATURE_PACKAGES_obmc-user-mgmt ?= "${@df_enabled('obmc-phosphor-user-mgmt', 'virtual-obmc-user-mgmt', d)}"
+FEATURE_PACKAGES_obmc-fan-mgmt ?= "${@cf_enabled('obmc-phosphor-fan-mgmt', 'virtual-obmc-fan-mgmt', d)}"
+FEATURE_PACKAGES_obmc-flash-mgmt ?= "${@cf_enabled('obmc-phosphor-flash-mgmt', 'virtual-obmc-flash-mgmt', d)}"
+FEATURE_PACKAGES_obmc-host-ctl ?= "${@cf_enabled('obmc-host-ctl', 'virtual-obmc-host-ctl', d)}"
+FEATURE_PACKAGES_obmc-host-ipmi ?= "${@cf_enabled('obmc-host-ipmi', 'virtual-obmc-host-ipmi-hw', d)}"
+FEATURE_PACKAGES_obmc-host-state-mgmt ?= "${@cf_enabled('obmc-host-state-mgmt', 'virtual-obmc-host-state-mgmt', d)}"
+FEATURE_PACKAGES_obmc-logging-mgmt ?= "${@df_enabled('obmc-logging-mgmt', 'virtual-obmc-logging-mgmt', d)}"
+FEATURE_PACKAGES_obmc-sensor-mgmt ?= "${@cf_enabled('obmc-phosphor-sensor-mgmt', 'virtual-obmc-sensor-mgmt', d)}"
 FEATURE_PACKAGES_obmc-settings-mgmt ?= "${@df_enabled('obmc-settings-mgmt', 'virtual-obmc-settings-mgmt', d)}"
 FEATURE_PACKAGES_obmc-system-mgmt ?= "${@df_enabled('obmc-phosphor-system-mgmt', 'virtual-obmc-system-mgmt', d)}"
-FEATURE_PACKAGES_obmc-host-ipmi ?= "${@cf_enabled('obmc-host-ipmi', 'virtual-obmc-host-ipmi-hw', d)}"
-FEATURE_PACKAGES_obmc-logging-mgmt ?= "${@df_enabled('obmc-logging-mgmt', 'virtual-obmc-logging-mgmt', d)}"
-FEATURE_PACKAGES_obmc-host-ctl ?= "${@cf_enabled('obmc-host-ctl', 'virtual-obmc-host-ctl', d)}"
-FEATURE_PACKAGES_obmc-host-state-mgmt ?= "${@cf_enabled('obmc-host-state-mgmt', 'virtual-obmc-host-state-mgmt', d)}"
-FEATURE_PACKAGES_obmc-chassis-state-mgmt ?= "${@cf_enabled('obmc-chassis-state-mgmt', 'virtual-obmc-chassis-state-mgmt', d)}"
-FEATURE_PACKAGES_obmc-bmc-state-mgmt ?= "${@cf_enabled('obmc-bmc-state-mgmt', 'virtual-obmc-bmc-state-mgmt', d)}"
+FEATURE_PACKAGES_obmc-user-mgmt ?= "${@df_enabled('obmc-phosphor-user-mgmt', 'virtual-obmc-user-mgmt', d)}"
 
 # Install entire Phosphor application stack by default
 IMAGE_FEATURES += " \
-        obmc-fan-mgmt \
+        obmc-bmc-state-mgmt \
         obmc-chassis-mgmt \
-        obmc-sensor-mgmt \
-        obmc-flash-mgmt \
+        obmc-chassis-state-mgmt \
         obmc-event-mgmt \
-        obmc-user-mgmt \
+        obmc-fan-mgmt \
+        obmc-flash-mgmt \
+        obmc-host-ctl \
+        obmc-host-ipmi \
+        obmc-host-state-mgmt \
+        obmc-logging-mgmt \
+        obmc-sensor-mgmt \
         obmc-settings-mgmt \
         obmc-system-mgmt \
-        obmc-host-ipmi \
-        obmc-logging-mgmt \
-        obmc-host-ctl \
+        obmc-user-mgmt \
         ssh-server-dropbear \
-        obmc-host-state-mgmt \
-        obmc-chassis-state-mgmt \
-        obmc-bmc-state-mgmt \
         "
 
 CORE_IMAGE_EXTRA_INSTALL_append = " bash \
diff --git a/meta-phosphor/conf/distro/include/phosphor-defaults.inc b/meta-phosphor/conf/distro/include/phosphor-defaults.inc
index 5bada92..54b98bc 100644
--- a/meta-phosphor/conf/distro/include/phosphor-defaults.inc
+++ b/meta-phosphor/conf/distro/include/phosphor-defaults.inc
@@ -1,27 +1,27 @@
-OBMC_CHASSIS_INSTANCES ?= "0"
-OBMC_POWER_INSTANCES ?= "0"
-OBMC_CHECKSTOP_INSTANCES ?= "0"
-OBMC_HOST_INSTANCES ?= "0"
-OBMC_WATCHDOG_INSTANCES ?= "0"
-OBMC_RESET_BUTTON_INSTANCES ?= "0"
-OBMC_POWER_BUTTON_INSTANCES ?= "0"
 OBMC_BMC_INSTANCES ?= "0"
+OBMC_CHASSIS_INSTANCES ?= "0"
+OBMC_CHECKSTOP_INSTANCES ?= "0"
 OBMC_FAN_INSTANCES ?= ""
+OBMC_HOST_INSTANCES ?= "0"
+OBMC_POWER_BUTTON_INSTANCES ?= "0"
+OBMC_POWER_INSTANCES ?= "0"
+OBMC_RESET_BUTTON_INSTANCES ?= "0"
+OBMC_WATCHDOG_INSTANCES ?= "0"
 
-PREFERRED_PROVIDER_virtual/obmc-wsgihost ?= "phosphor-gevent"
-PREFERRED_PROVIDER_virtual/obmc-event-mgmt ?= "obmc-phosphor-event"
-PREFERRED_PROVIDER_virtual/obmc-user-mgmt ?= "obmc-phosphor-user"
-PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw ?= "phosphor-ipmi-hw-example"
+PREFERRED_PROVIDER_virtual/obmc-bmc-state-mgmt ?= "phosphor-state-manager"
 PREFERRED_PROVIDER_virtual/obmc-chassis-mgmt ?= "obmc-phosphor-chassisd"
+PREFERRED_PROVIDER_virtual/obmc-chassis-state-mgmt ?= "phosphor-state-manager"
+PREFERRED_PROVIDER_virtual/obmc-event-mgmt ?= "obmc-phosphor-event"
 PREFERRED_PROVIDER_virtual/obmc-fan-mgmt ?= "obmc-phosphor-fand"
 PREFERRED_PROVIDER_virtual/obmc-flash-mgmt ?= "obmc-phosphor-flashd"
-PREFERRED_PROVIDER_virtual/obmc-sensor-mgmt ?= "obmc-phosphor-sensord"
-PREFERRED_PROVIDER_virtual/obmc-system-mgmt ?= "obmc-phosphor-sysd"
-PREFERRED_PROVIDER_virtual/obmc-settings-mgmt ?= "phosphor-settings"
-PREFERRED_PROVIDER_virtual/obmc-logging-mgmt ?= "phosphor-logging"
+PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw ?= "phosphor-ipmi-hw-example"
 PREFERRED_PROVIDER_virtual/obmc-host-state-mgmt ?= "phosphor-state-manager"
-PREFERRED_PROVIDER_virtual/obmc-chassis-state-mgmt ?= "phosphor-state-manager"
-PREFERRED_PROVIDER_virtual/obmc-bmc-state-mgmt ?= "phosphor-state-manager"
+PREFERRED_PROVIDER_virtual/obmc-logging-mgmt ?= "phosphor-logging"
+PREFERRED_PROVIDER_virtual/obmc-sensor-mgmt ?= "obmc-phosphor-sensord"
+PREFERRED_PROVIDER_virtual/obmc-settings-mgmt ?= "phosphor-settings"
+PREFERRED_PROVIDER_virtual/obmc-system-mgmt ?= "obmc-phosphor-sysd"
+PREFERRED_PROVIDER_virtual/obmc-user-mgmt ?= "obmc-phosphor-user"
+PREFERRED_PROVIDER_virtual/obmc-wsgihost ?= "phosphor-gevent"
 
 # virtual/phosphor-ipmi-fru-config
 #