treewide: remove obmc-op-control-host for non-openpower machines

The code for obmc-op-control-host is only useful for OpenPower
machines, but somehow it is being included in many other machines.
Remove it from all of them except meta-openpower.

Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
Change-Id: I4e7c7365eb320c3fb9ea7a57aca2ed0b1832e85e
diff --git a/meta-amd/meta-ethanolx/conf/machine/ethanolx.conf b/meta-amd/meta-ethanolx/conf/machine/ethanolx.conf
index 67fc64c..bc62aec 100644
--- a/meta-amd/meta-ethanolx/conf/machine/ethanolx.conf
+++ b/meta-amd/meta-ethanolx/conf/machine/ethanolx.conf
@@ -36,7 +36,6 @@
 PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw ?= "phosphor-ipmi-kcs"
 PREFERRED_PROVIDER_virtual/obmc-inventory-data ?= "${VIRTUAL-RUNTIME_skeleton_workbook}"
 PREFERRED_PROVIDER_virtual/obmc-system-mgmt = "packagegroup-amd-apps"
-PREFERRED_PROVIDER_virtual/obmc-host-ctl ?= "obmc-op-control-host"
 PREFERRED_PROVIDER_virtual/phosphor-led-manager-config-native = "ethanolx-led-manager-config-native"
 
 OVERRIDES .= ":amd"
diff --git a/meta-intel-openbmc/conf/machine/include/intel.inc b/meta-intel-openbmc/conf/machine/include/intel.inc
index 4374a8c..7118771 100644
--- a/meta-intel-openbmc/conf/machine/include/intel.inc
+++ b/meta-intel-openbmc/conf/machine/include/intel.inc
@@ -3,7 +3,6 @@
         obmc-phosphor-chassis-mgmt \
         obmc-phosphor-flash-mgmt \
         obmc-host-ipmi \
-        obmc-host-ctl \
         obmc-host-state-mgmt \
         obmc-chassis-state-mgmt \
         obmc-bmc-state-mgmt \
@@ -15,7 +14,6 @@
 PREFERRED_PROVIDER_virtual/obmc-fan-mgmt = "packagegroup-intel-apps"
 PREFERRED_PROVIDER_virtual/obmc-flash-mgmt = "packagegroup-intel-apps"
 PREFERRED_PROVIDER_virtual/obmc-system-mgmt = "packagegroup-intel-apps"
-PREFERRED_PROVIDER_virtual/obmc-host-ctl ?= "obmc-op-control-host"
 PREFERRED_PROVIDER_virtual/obmc-inventory-data ?= "${VIRTUAL-RUNTIME_skeleton_workbook}"
 PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw = "phosphor-ipmi-kcs"
 
diff --git a/meta-inventec/conf/machine/include/inventec.inc b/meta-inventec/conf/machine/include/inventec.inc
index 9b6206c..7b57f54 100644
--- a/meta-inventec/conf/machine/include/inventec.inc
+++ b/meta-inventec/conf/machine/include/inventec.inc
@@ -3,7 +3,6 @@
         obmc-phosphor-chassis-mgmt \
         obmc-phosphor-flash-mgmt \
         obmc-host-ipmi \
-        obmc-host-ctl \
         obmc-host-state-mgmt \
         obmc-chassis-state-mgmt \
         obmc-bmc-state-mgmt \
@@ -18,7 +17,6 @@
 PREFERRED_PROVIDER_virtual/obmc-fan-mgmt = "packagegroup-inventec-apps"
 PREFERRED_PROVIDER_virtual/obmc-flash-mgmt = "packagegroup-inventec-apps"
 PREFERRED_PROVIDER_virtual/obmc-system-mgmt = "packagegroup-inventec-apps"
-PREFERRED_PROVIDER_virtual/obmc-host-ctl ?= "obmc-op-control-host"
 PREFERRED_PROVIDER_virtual/obmc-inventory-data ?= "${VIRTUAL-RUNTIME_skeleton_workbook}"
 PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw = "phosphor-ipmi-kcs"
 
diff --git a/meta-supermicro/conf/machine/include/supermicro.inc b/meta-supermicro/conf/machine/include/supermicro.inc
index d663f445..dc68db6 100644
--- a/meta-supermicro/conf/machine/include/supermicro.inc
+++ b/meta-supermicro/conf/machine/include/supermicro.inc
@@ -3,7 +3,6 @@
         obmc-chassis-state-mgmt \
         obmc-host-state-mgmt \
         obmc-host-ipmi \
-        obmc-host-ctl \
         obmc-phosphor-chassis-mgmt \
         obmc-phosphor-fan-mgmt \
         obmc-phosphor-flash-mgmt \
@@ -15,7 +14,6 @@
 PREFERRED_PROVIDER_virtual/obmc-fan-mgmt = "packagegroup-supermicro-apps"
 PREFERRED_PROVIDER_virtual/obmc-flash-mgmt = "packagegroup-supermicro-apps"
 PREFERRED_PROVIDER_virtual/obmc-system-mgmt = "packagegroup-supermicro-apps"
-PREFERRED_PROVIDER_virtual/obmc-host-ctl ?= "obmc-op-control-host"
 PREFERRED_PROVIDER_virtual/obmc-inventory-data ?= "${VIRTUAL-RUNTIME_skeleton_workbook}"
 PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw ?= "phosphor-ipmi-kcs"