blob: 3b4d9d9aec854acddc904aaaaec0e2e50d0b0e3b [file] [log] [blame]
#!/bin/bash
# Power off the hosts when fan sensors crossed thresholds.
echo "Power off the hosts if fansensors threshold crossed ::"
HOST_INSTANCES="HOST_INSTANCES_SED_REPLACEMENT_VALUE"
DBUS_SERVICE="xyz.openbmc_project.State.Chassis"
DBUS_OBJECT="/xyz/openbmc_project/state/chassis"
DBUS_INTERFACE="xyz.openbmc_project.State.Chassis"
DBUS_PROPERTY="RequestedPowerTransition"
PROPERTY_VALUE="xyz.openbmc_project.State.Chassis.Transition.Off"
# Power off the hosts.
power-off-all-hosts()
{
for host_id in $HOST_INSTANCES
do
echo "chosen host id :::$host_id"
# host power off
output=$(busctl set-property $DBUS_SERVICE"$host_id" $DBUS_OBJECT"$host_id" $DBUS_INTERFACE $DBUS_PROPERTY s $PROPERTY_VALUE)
echo "$output"
done
}
power-off-all-hosts