<attn_node model_ec="P10_10,P10_20" name="MC_MISC_FIR" reg_type="SCOM">
<local_fir config="W2" name="MC_MISC_FIR">
<instance addr="0x0C010F00" reg_inst="0"/>
<instance addr="0x0D010F00" reg_inst="1"/>
<instance addr="0x0E010F00" reg_inst="2"/>
<instance addr="0x0F010F00" reg_inst="3"/>
<action attn_type="CS" config="000"/>
<action attn_type="RE" config="010"/>
<action attn_type="SPA" config="100"/>
<action attn_type="UCS" config="110"/>
<action attn_type="HA" config="001"/>
</local_fir>
<register name="MC_MISC_ERR_RPT">
<instance addr="0x0C010FE7" reg_inst="0"/>
<instance addr="0x0D010FE7" reg_inst="1"/>
<instance addr="0x0E010FE7" reg_inst="2"/>
<instance addr="0x0F010FE7" reg_inst="3"/>
</register>
<capture_group node_inst="0:3">
<capture_register reg_inst="0:3" reg_name="MC_MISC_ERR_RPT" />
</capture_group>
<bit pos="0">WAT Debug Bus Attention</bit>
<bit pos="1">SCOM DBGSRC Register parity Error</bit>
<bit pos="2">SCOM Recoverable Register Parity Error</bit>
<bit pos="3">spare</bit>
<bit pos="4">Application interrupt received from OCMB on channel 0, subchannel A</bit>
<bit pos="5">Application interrupt received from OCMB on channel 0, subchannel B</bit>
<bit pos="6">Application interrupt received from OCMB on channel 1, subchannel A</bit>
<bit pos="7">Application interrupt received from OCMB on channel 1, subchannel B</bit>
<bit pos="8">Parity Error taken on MCEBUSEN[0,1,2,3] regs</bit>
<bit pos="9">Parity Error taken on WAT* Regs</bit>
<bit pos="10">Reserved</bit>
<bit pos="11">Reserved</bit>
</attn_node>