blob: 9dc209dc8d3442ce3566a5e9e23e0271292db95a [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<attn_node model_ec="P10_20" name="MC_FIR" reg_type="SCOM">
<local_fir config="W2" name="MC_FIR">
<instance addr="0x0C010C00" reg_inst="0"/>
<instance addr="0x0D010C00" reg_inst="1"/>
<instance addr="0x0E010C00" reg_inst="2"/>
<instance addr="0x0F010C00" reg_inst="3"/>
<action attn_type="CS" config="000"/>
<action attn_type="RE" config="010"/>
<action attn_type="SPA" config="100"/>
<action attn_type="UCS" config="110"/>
<action attn_type="HA" config="001"/>
</local_fir>
<register name="MC_ERR_RPT0">
<instance addr="0x0C010C1E" reg_inst="0"/>
<instance addr="0x0D010C1E" reg_inst="1"/>
<instance addr="0x0E010C1E" reg_inst="2"/>
<instance addr="0x0F010C1E" reg_inst="3"/>
</register>
<register name="MC_ERR_RPT1">
<instance addr="0x0C010C1F" reg_inst="0"/>
<instance addr="0x0D010C1F" reg_inst="1"/>
<instance addr="0x0E010C1F" reg_inst="2"/>
<instance addr="0x0F010C1F" reg_inst="3"/>
</register>
<register name="MC_ERR_RPT2">
<instance addr="0x0C010C1A" reg_inst="0"/>
<instance addr="0x0D010C1A" reg_inst="1"/>
<instance addr="0x0E010C1A" reg_inst="2"/>
<instance addr="0x0F010C1A" reg_inst="3"/>
</register>
<capture_group node_inst="0:3">
<capture_register reg_inst="0:3" reg_name="MC_ERR_RPT0" />
<capture_register reg_inst="0:3" reg_name="MC_ERR_RPT1" />
<capture_register reg_inst="0:3" reg_name="MC_ERR_RPT2" />
</capture_group>
<bit pos="0">MC internal recoverable error</bit>
<bit pos="1">MC internal non-recoverable error</bit>
<bit pos="2">MC powerbus protocol error</bit>
<bit pos="3">MC inband bar with incorrect ttype</bit>
<bit pos="4">MC multiple BAR hit</bit>
<bit pos="5">Command list early hang trigger activated</bit>
<bit pos="6">reserved</bit>
<bit pos="7">reserved</bit>
<bit pos="8">Command list state machine timeout</bit>
<bit pos="9">reserved</bit>
<bit pos="10">reserved</bit>
<bit pos="11">WAT0 event occurred</bit>
<bit pos="12">WAT1 event occurred</bit>
<bit pos="13">WAT2 event occurred</bit>
<bit pos="14">WAT3 event occurred</bit>
<bit pos="15">Plus One Prefetch generated command did not hit any BARs</bit>
<bit pos="16">Plus One Prefetch generated command hit config or mmio BAR</bit>
<bit pos="17">Parity Error in WAT/Debug config register</bit>
<bit pos="18">PBI received overcommit signal from READ0</bit>
<bit pos="19">PBI received ocercommit signal from READ1</bit>
<bit pos="20">Incoming Powerbus Command hit multiple valid configured topology IDs</bit>
<bit pos="21">reserved</bit>
<bit pos="22">Secure mem facility access privilege error by originating thread</bit>
<bit pos="23">Multiple sync cmds received by an MC, or while one is pending</bit>