blob: 8fe18bbda9dbe72ce1ae5951c603eb099437f373 [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<attn_node model_ec="P10_10,P10_20" name="PCI_NEST_FIR" reg_type="SCOM">
<local_fir config="W" name="PCI_NEST_FIR">
<instance addr="0x03011840" reg_inst="0"/>
<instance addr="0x03011880" reg_inst="1"/>
<instance addr="0x030118C0" reg_inst="2"/>
<instance addr="0x02011840" reg_inst="3"/>
<instance addr="0x02011880" reg_inst="4"/>
<instance addr="0x020118C0" reg_inst="5"/>
<action attn_type="CS" config="00"/>
<action attn_type="RE" config="01"/>
</local_fir>
<register name="PCI_NFIR_ERR_RPT0">
<instance reg_inst="0" addr="0x0301184A" />
<instance reg_inst="1" addr="0x0301188A" />
<instance reg_inst="2" addr="0x030118CA" />
<instance reg_inst="3" addr="0x0201184A" />
<instance reg_inst="4" addr="0x0201188A" />
<instance reg_inst="5" addr="0x020118CA" />
</register>
<register name="PCI_NFIR_ERR_RPT1">
<instance reg_inst="0" addr="0x0301184B" />
<instance reg_inst="1" addr="0x0301188B" />
<instance reg_inst="2" addr="0x030118CB" />
<instance reg_inst="3" addr="0x0201184B" />
<instance reg_inst="4" addr="0x0201188B" />
<instance reg_inst="5" addr="0x020118CB" />
</register>
<capture_group node_inst="0:5">
<capture_register reg_name="PCI_NFIR_ERR_RPT0" reg_inst="0:5" />
<capture_register reg_name="PCI_NFIR_ERR_RPT1" reg_inst="0:5" />
</capture_group>
<bit pos="0">BAR Parity Error</bit>
<bit pos="1">Non-BAR Parity Error</bit>
<bit pos="2">Power Bus to PEC CE</bit>
<bit pos="3">Power Bus to PEC UE</bit>
<bit pos="4">Power Bus to PEC SUE</bit>
<bit pos="5">Array CE</bit>
<bit pos="6">Array UE</bit>
<bit pos="7">Array SUE</bit>
<bit pos="8">Register Array Parity Error</bit>
<bit pos="9">Power Bus Interface Parity Error</bit>
<bit pos="10">Power Bus Data Hang</bit>
<bit pos="11">Power Bus Hang Error</bit>
<bit pos="12">RD ARE Error</bit>
<bit pos="13">Non-Rd ARE Error</bit>
<bit pos="14">PCI Hang Error</bit>
<bit pos="15">PCI Clock Error</bit>
<bit pos="16">AIB Fence</bit>
<bit pos="17">Hardware Error</bit>
<bit pos="18">Unsolicited Power Bus Data</bit>
<bit pos="19">Unexpected Combined Response</bit>
<bit pos="20">Invalid Combined Response</bit>
<bit pos="21">Power Bus Unsupported Size</bit>
<bit pos="22">Power Bus Unsupported Command</bit>
<bit pos="23">reserved</bit>
<bit pos="24">reserved</bit>
<bit pos="25">reserved</bit>
<bit pos="26">Software Defined</bit>
<bit pos="27">PEC SCOM Engine Error</bit>
</attn_node>