blob: 186d1564b9dadde014a57b4c119dc5925418d2af [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<attn_node model_ec="P10_10,P10_20" name="MCD_FIR" reg_type="SCOM">
<local_fir config="W" name="MCD_FIR">
<instance addr="0x03010800" reg_inst="0"/>
<action attn_type="CS" config="00"/>
<action attn_type="RE" config="01"/>
<action attn_type="SPA" config="10"/>
</local_fir>
<bit pos="0">MCD array ECC correctable error</bit>
<bit pos="1">MCD array ECC uncorrectable error</bit>
<bit pos="2">MCD PowerBus address parity error</bit>
<bit pos="3">MCD invalid state error</bit>
<bit pos="4">Hang poll timer expired on cl_probe</bit>
<bit pos="5">PowerBus address error cresp received</bit>
<bit pos="6">MCD received a unsolicited CRESP</bit>
<bit pos="7">MCD powerbus ttag parity error</bit>
<bit pos="8">MCD scom register update error</bit>
<bit pos="9">MCD received a ack_dead_cresp</bit>
<bit pos="10">MCD configuration register had a parity error</bit>
</attn_node>