blob: e366cd91c9e5c8bc7f19a8217d2eca234660c814 [file] [log] [blame]
{
"version": 1,
"model_ec": ["P10_20"],
"registers": {
"VAS_FIR": {
"instances": {
"0": "0x02011400"
}
},
"VAS_FIR_MASK": {
"instances": {
"0": "0x02011403"
}
},
"VAS_FIR_ACT0": {
"instances": {
"0": "0x02011406"
}
},
"VAS_FIR_ACT1": {
"instances": {
"0": "0x02011407"
}
},
"VAS_FIR_WOF": {
"instances": {
"0": "0x02011408"
}
}
},
"isolation_nodes": {
"VAS_FIR": {
"instances": [0],
"rules": [
{
"attn_type": ["CHIP_CS"],
"node_inst": [0],
"expr": {
"expr_type": "and",
"exprs": [
{
"expr_type": "reg",
"reg_name": "VAS_FIR"
},
{
"expr_type": "not",
"expr": {
"expr_type": "reg",
"reg_name": "VAS_FIR_MASK"
}
},
{
"expr_type": "not",
"expr": {
"expr_type": "reg",
"reg_name": "VAS_FIR_ACT0"
}
},
{
"expr_type": "not",
"expr": {
"expr_type": "reg",
"reg_name": "VAS_FIR_ACT1"
}
}
]
}
},
{
"attn_type": ["RECOV"],
"node_inst": [0],
"expr": {
"expr_type": "and",
"exprs": [
{
"expr_type": "reg",
"reg_name": "VAS_FIR"
},
{
"expr_type": "not",
"expr": {
"expr_type": "reg",
"reg_name": "VAS_FIR_MASK"
}
},
{
"expr_type": "not",
"expr": {
"expr_type": "reg",
"reg_name": "VAS_FIR_ACT0"
}
},
{
"expr_type": "reg",
"reg_name": "VAS_FIR_ACT1"
}
]
}
},
{
"attn_type": ["UNIT_CS"],
"node_inst": [0],
"expr": {
"expr_type": "and",
"exprs": [
{
"expr_type": "reg",
"reg_name": "VAS_FIR"
},
{
"expr_type": "not",
"expr": {
"expr_type": "reg",
"reg_name": "VAS_FIR_MASK"
}
},
{
"expr_type": "reg",
"reg_name": "VAS_FIR_ACT0"
},
{
"expr_type": "reg",
"reg_name": "VAS_FIR_ACT1"
}
]
}
}
],
"bits": {
"0": {
"desc": "Hardware error detected in Egress logic"
},
"1": {
"desc": "Hardware error detected in Ingress logic"
},
"2": {
"desc": "Hardware error detected in CQ logic"
},
"3": {
"desc": "Hardware error detected in WC logic"
},
"4": {
"desc": "Hardware error detected in RG logic"
},
"5": {
"desc": "PowerBus parity error detected on CQ logic interface"
},
"6": {
"desc": "CQ logic detected PowerBus address error on CRESP from a read operation"
},
"7": {
"desc": "CQ logic detected PowerBus address error on CRESP from a write operation"
},
"8": {
"desc": "Correctable ECC error detected in Egress logic"
},
"9": {
"desc": "Correctable ECC error detected in Ingress logic"
},
"10": {
"desc": "Correctable ECC error detected in CQ logic"
},
"11": {
"desc": "Correctable ECC error detected in WC logic"
},
"12": {
"desc": "Correctable ECC error detected in RG logic"
},
"13": {
"desc": "ECC Correctable Error detected on CQ outbound PB interface"
},
"14": {
"desc": "ECC Uncorrectable Error detected on CQ outbound PB interface"
},
"15": {
"desc": "PowerBus state machine hang detected in CQ logic"
},
"16": {
"desc": "Uncorrectable ECC error detected in Egress logic"
},
"17": {
"desc": "Uncorrectable ECC error detected in Ingress logic"
},
"18": {
"desc": "Uncorrectable ECC error detected in CQ logic"
},
"19": {
"desc": "Uncorrectable ECC error detected in WC logic"
},
"20": {
"desc": "Uncorrectable ECC error detected in RG logic"
},
"21": {
"desc": "Parity error detected in Ingress logic"
},
"22": {
"desc": "Software cast error detected in Ingress logic"
},
"23": {
"desc": "reserved"
},
"24": {
"desc": "ECC sue error detected in Egress logic"
},
"25": {
"desc": "ECC sue error detected in Ingress logic"
},
"26": {
"desc": "ECC sue error detected in CQ logic"
},
"27": {
"desc": "ECC sue error detected in WC logic"
},
"28": {
"desc": "ECC sue error detected in RG logic"
},
"29": {
"desc": "PowerBus link error detected on read operation in CQ logic"
},
"30": {
"desc": "PowerBus link error detected on write operation in CQ logic"
},
"31": {
"desc": "PowerBus link abort operation received in CQ logic"
},
"32": {
"desc": "Address error detected on hypervisor MMIO read"
},
"33": {
"desc": "Address error detected on OS MMIO read"
},
"34": {
"desc": "Address error detected on hypervisor MMIO write"
},
"35": {
"desc": "Address error detected on OS MMIO write"
},
"36": {
"desc": "non-8-Byte MMIO detected by hypervisor"
},
"37": {
"desc": "non-8-Byte MMIO detected by user or OS"
},
"38": {
"desc": "reserved"
},
"39": {
"desc": "reserved"
},
"40": {
"desc": "reserved"
},
"41": {
"desc": "reserved"
},
"42": {
"desc": "ASB_Notify sent but not claimed and interrupts were disabled in window context"
},
"43": {
"desc": "reserved"
},
"44": {
"desc": "VAS rejected a PB paste command"
},
"45": {
"desc": "VAS hung waiting for data from PowerBus"
},
"46": {
"desc": "Incoming PowerBus parity error"
},
"47": {
"desc": "HW error from SCOM Satellite 1"
},
"48": {
"desc": "NX Local Checkstop"
},
"49": {
"desc": "SCOM MMIO address offset error"
},
"50": {
"desc": "TopoID Error Bit"
},
"51": {
"desc": "spare"
}
}
}
}
}