blob: 8cca801e3aad80b381206e6f7880eb13ca43db10 [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<attn_node model_ec="P10_10" name="NMMU_CQ_FIR" reg_type="SCOM">
<local_fir config="W" name="NMMU_CQ_FIR">
<instance addr="0x02010C00" reg_inst="0"/>
<instance addr="0x03010C00" reg_inst="1"/>
<action attn_type="CS" config="00"/>
<action attn_type="RE" config="01"/>
<action attn_type="UCS" config="11"/>
</local_fir>
<bit pos="0">PBI internal parity error</bit>
<bit pos="1">PowerBus command hang error</bit>
<bit pos="2">PowerBus read address error</bit>
<bit pos="3">PowerBus write address error</bit>
<bit pos="4">PowerBus miscellaneous error</bit>
<bit pos="5">Reserved</bit>
<bit pos="6">PowerBus Xlate UE error</bit>
<bit pos="7">PowerBus Xlate SUE error</bit>
<bit pos="8">PowerBus CE error</bit>
<bit pos="9">PowerBus UE error</bit>
<bit pos="10">PowerBus SUE error</bit>
<bit pos="11">Inbound LCO_ARRAY CE error</bit>
<bit pos="12">Inbound LCO_ARRAY UE error</bit>
<bit pos="13">Inbound LCO_ARRAY SUE error</bit>
<bit pos="14">Inbound array CE error</bit>
<bit pos="15">Inbound array UE error</bit>
<bit pos="16">internal state error</bit>
<bit pos="17">ACK_DEAD cresp received by read command</bit>
<bit pos="18">ACK_DEAD cresp received by write command</bit>
<bit pos="19">Link check aborted while waiting on data</bit>
</attn_node>