blob: 0a903148cc48624eb5a3dae1db581cf74f6add55 [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<attn_node model_ec="P10_10" name="VAS_FIR" reg_type="SCOM">
<local_fir config="W" name="VAS_FIR">
<instance addr="0x02011400" reg_inst="0"/>
<action attn_type="CS" config="00"/>
<action attn_type="RE" config="01"/>
<action attn_type="UCS" config="11"/>
</local_fir>
<bit pos="0">Hardware error detected in Egress logic</bit>
<bit pos="1">Hardware error detected in Ingress logic</bit>
<bit pos="2">Hardware error detected in CQ logic</bit>
<bit pos="3">Hardware error detected in WC logic</bit>
<bit pos="4">Hardware error detected in RG logic</bit>
<bit pos="5">PowerBus parity error detected on CQ logic interface</bit>
<bit pos="6">CQ logic detected PowerBus address error on CRESP from a read operation</bit>
<bit pos="7">CQ logic detected PowerBus address error on CRESP from a write operation</bit>
<bit pos="8">Correctable ECC error detected in Egress logic</bit>
<bit pos="9">Correctable ECC error detected in Ingress logic</bit>
<bit pos="10">Correctable ECC error detected in CQ logic</bit>
<bit pos="11">Correctable ECC error detected in WC logic</bit>
<bit pos="12">Correctable ECC error detected in RG logic</bit>
<bit pos="13">ECC Correctable Error detected on CQ outbound PowerBus interface</bit>
<bit pos="14">ECC UNCorrectable Error detected on CQ outbound PowerBus interface</bit>
<bit pos="15">PowerBus state machine hang detected in CQ logic</bit>
<bit pos="16">Uncorrectable ECC error detected in Egress logic</bit>
<bit pos="17">Uncorrectable ECC error detected in Ingress logic</bit>
<bit pos="18">Uncorrectable ECC error detected in CQ logic</bit>
<bit pos="19">Uncorrectable ECC error detected in WC logic</bit>
<bit pos="20">Uncorrectable ECC error detected in RG logic</bit>
<bit pos="21">Parity error detected in Ingress logic</bit>
<bit pos="22">Software cast error detected in Ingress logic</bit>
<bit pos="23">VAS attempted to access a memory address which has the secure memory bit set</bit>
<bit pos="24">ECC sue error detected in Egress logic</bit>
<bit pos="25">ECC sue error detected in Ingress logic</bit>
<bit pos="26">ECC sue error detected in CQ logic</bit>
<bit pos="27">ECC sue error detected in WC logic</bit>
<bit pos="28">ECC sue error detected in RG logic</bit>
<bit pos="29">PowerBus link error detected on read operation in CQ logic</bit>
<bit pos="30">PowerBus link error detected on write operation in CQ logic</bit>
<bit pos="31">PowerBus link abort operation received in CQ logic</bit>
<bit pos="32">Address error detected on hypervisor MMIO read</bit>
<bit pos="33">Address error detected on OS MMIO read</bit>
<bit pos="34">Address error detected on hypervisor MMIO write</bit>
<bit pos="35">Address error detected on OS MMIO write</bit>
<bit pos="36">non-8-Byte MMIO detected by hypervisor</bit>
<bit pos="37">non-8-Byte MMIO detected by user or OS</bit>
<bit pos="38">Unused - Was Write monitor operation attempted on a window that is not open</bit>
<bit pos="39">Unused - Was Multiple write monotor registers match the same snooped PB operation</bit>
<bit pos="40">Unused - Was Page Migration Register is not valid</bit>
<bit pos="41">Unused - Was Page Migration Register size does not match corresponding FIFO</bit>
<bit pos="42">ASB_Notify sent but not claimed and interrupts were disabled in window context</bit>
<bit pos="43">Unused - Was Write monitor operation hit a window which has notification disabled</bit>
<bit pos="44">VAS rejected a PB paste command. See window status register for details</bit>
<bit pos="45">VAS hung waiting for data from PowerBus</bit>
<bit pos="46">Incoming PowerBus parity error</bit>
<bit pos="47">HW error from SCOM Satellite 1</bit>
<bit pos="48">NX Local Checkstop</bit>
<bit pos="49">SCOM MMIO address offset error. SCOM-initiated MMIO address did not decode to valid address.</bit>
<bit pos="50">TopoID Error Bit</bit>
<bit pos="51">Unused bit</bit>