blob: 15251de1af628cbd9468283875370300f560378d [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<attn_node model_ec="P10_20" name="MC_DSTL_FIR" reg_type="SCOM">
<local_fir config="W2" name="MC_DSTL_FIR">
<instance addr="0x0C010D00" reg_inst="0"/>
<instance addr="0x0C010D40" reg_inst="1"/>
<instance addr="0x0D010D00" reg_inst="2"/>
<instance addr="0x0D010D40" reg_inst="3"/>
<instance addr="0x0E010D00" reg_inst="4"/>
<instance addr="0x0E010D40" reg_inst="5"/>
<instance addr="0x0F010D00" reg_inst="6"/>
<instance addr="0x0F010D40" reg_inst="7"/>
<action attn_type="CS" config="000"/>
<action attn_type="RE" config="010"/>
<action attn_type="SPA" config="100"/>
<action attn_type="UCS" config="110"/>
<action attn_type="HA" config="001"/>
</local_fir>
<bit pos="0">AFU initiated Checkstop on Subchannel A</bit>
<bit pos="1">AFU initiated Recoverable Attention on Subchannel A</bit>
<bit pos="2">AFU initiated Special Attention on Subchannel A</bit>
<bit pos="3">AFU initiated Application Interrupt Attention on Subchannel A</bit>
<bit pos="4">AFU initiated Checkstop on Subchannel B</bit>
<bit pos="5">AFU initiated Recoverable Attention on Subchannel B</bit>
<bit pos="6">AFU initiated Special Attention on Subchannel B</bit>
<bit pos="7">AFU initiated Application Interrupt Attention on Subchannel B</bit>
<bit pos="8">Error on parity bits protecting incoming command from MCS to DSTL.</bit>
<bit pos="9">A credit reset was attempted while rd and wdf buffers in use.</bit>
<bit pos="10">DSTL Configuration Register has taken a recoverable parity error.</bit>
<bit pos="11">DSTL Configuration Register has taken a fatal parity error.</bit>
<bit pos="12">DSTL Subchannel A, a counter took an underflow or overflow error.</bit>
<bit pos="13">DSTL Subchannel B, a counter took an underflow or overflow error.</bit>
<bit pos="14">DSTL Subchannel A timed out having valid commands and not sending any flits.</bit>
<bit pos="15">DSTL Subchannel B timed out having valid commands and not sending any flits.</bit>
<bit pos="16">DSTL has detected that attached buffer on subchannel A has used more tlxvc0 or tlxvc3 credits than it has been given.</bit>
<bit pos="17">DSTL has detected that attached buffer on subchannel B has used more tlxvc0 or tlxvc3 credits than it has been given.</bit>
<bit pos="18">DSTL Subchannel A observed link going down.</bit>
<bit pos="19">DSTL Subchannel B observed link going down.</bit>
<bit pos="20">DSTL Subchannel A has entered the fail state.</bit>
<bit pos="21">DSTL Subchannel B has entered the fail state.</bit>
<bit pos="22">Channel timeout has occured on Subchannel A index.</bit>
<bit pos="23">Channel timeout has occured on Subchannel B index.</bit>
<bit pos="24">Error info from decrypt</bit>
<bit pos="25">Error info from decrypt</bit>
<bit pos="26">Error info from decrypt</bit>
<bit pos="27">Error info from decrypt</bit>
<bit pos="28">Error info from decrypt</bit>
<bit pos="29">Error info from encrypt</bit>
<bit pos="30">Error info from encrypt</bit>
<bit pos="31">Error info from encrypt</bit>
<bit pos="32">Error info from encrypt</bit>
<bit pos="33">On Subchhanel A, received an AFU initiated Application Interrupt Attention when one was already being processed and issued a retry.</bit>
<bit pos="34">On Subchhanel B, received an AFU initiated Application Interrupt Attention when one was already being processed and issued a retry.</bit>
<bit pos="35">A parity error local to Subchhanel A occurred.</bit>
<bit pos="36">A parity error local to Subchhanel B occurred.</bit>
<bit pos="37">Spare FIR bit 37.</bit>
<bit pos="38">Spare FIR bit 38.</bit>
<bit pos="39">Indicates that this subchannel has significant traffic flow.</bit>
<bit pos="40">Indicates that this subchannel has significant traffic flow.</bit>
</attn_node>