blob: 6c82c2f8dcac78ec75737c915e8a9afba4278b66 [file] [log] [blame]
Zane Shelleyabc51c22020-11-09 21:35:35 -06001<?xml version="1.0" encoding="UTF-8"?>
2<attn_node model_ec="P10_10" name="TP_LOCAL_FIR" reg_type="SCOM">
3 <local_fir config="W2" name="TP_LOCAL_FIR">
4 <instance addr="0x01040100" reg_inst="0"/>
5 <action attn_type="CS" config="000"/>
6 <action attn_type="RE" config="010"/>
7 <action attn_type="SPA" config="100"/>
8 <action attn_type="UCS" config="110"/>
9 <action attn_type="HA" config="001"/>
10 </local_fir>
11 <bit pos="0">CFIR - Parity or PCB access error</bit>
12 <bit pos="1">CPLT_CTRL - PCB access error</bit>
13 <bit pos="2">CC - PCB access error - read and clear nn03000F</bit>
14 <bit pos="3">CC - Clock Control Error - read and clear nn03000F</bit>
15 <bit pos="4">PSC - PSCOM access error - read and clear nn01001</bit>
16 <bit pos="5">PSC - internal or ring interface error - read and clear nn01001</bit>
17 <bit pos="6">THERM - pwr_comp_err, skitter_comp_err, scan_init_version_reg_parity_err_out , count_state_err_out check ERR_STATUS_REG 0xnn050013</bit>
18 <bit pos="7">THERM - pcb error</bit>
19 <bit pos="8">THERMTRIP - Critical temperature indicator</bit>
20 <bit pos="9">THERMTRIP - Fatal temperature indicator</bit>
21 <bit pos="10">VOLTTRIP - Voltage sense error</bit>
22 <bit pos="11">DBG - scom parity fail</bit>
23 <bit pos="12">reserved</bit>
24 <bit pos="13">reserved</bit>
25 <bit pos="14">reserved</bit>
26 <bit pos="15">reserved</bit>
27 <bit pos="16">reserved</bit>
28 <bit pos="17">reserved</bit>
29 <bit pos="18">reserved</bit>
30 <bit pos="19">reserved</bit>
31 <bit pos="20">Trace00 - scom parity err</bit>
32 <bit pos="21">ITR - FMU error</bit>
33 <bit pos="22">ITR - PCB error</bit>
34 <bit pos="23">PCB Master - timeout - read and clear 000F001F - RECOV</bit>
35 <bit pos="24">I2CM - Parity errors, Can be considered as recoverable error</bit>
36 <bit pos="25">TOD - any error</bit>
37 <bit pos="26">TOD - access error PIB</bit>
38 <bit pos="27">TOD - unused tie0</bit>
39 <bit pos="28">PCB Slave - read and clear nn0F001F RECOV</bit>
40 <bit pos="29">SBE - PPE int hardware error</bit>
41 <bit pos="30">SBE - PPE ext hardware error</bit>
42 <bit pos="31">SBE- PPE code error</bit>
43 <bit pos="32">SBE - PPE debug code breakpoint</bit>
44 <bit pos="33">SBE - PPE in halted state</bit>
45 <bit pos="34">SBE - PPE watchdog timeout</bit>
46 <bit pos="35">SBE - unused tie0</bit>
47 <bit pos="36">SBE - unused tie0</bit>
48 <bit pos="37">SBE - PPE triggers DBG</bit>
49 <bit pos="38">OTP - SCOM access errors &amp; single ecc correctable errors. Can be considered as Recoverable type.</bit>
50 <bit pos="39">TPIO External Trigger</bit>
51 <bit pos="40">PCB Master - DECMCAST_GRP_ERR - read and clear 000F001F - RECOV</bit>
52 <bit pos="41">PCB Master - Parity ERR - read and clear 000F001F - RECOV</bit>
53 <bit pos="42">RCS - OSC0 Error</bit>
54 <bit pos="43">RCS - OSC1 Error</bit>
55 <bit pos="44">RCS - Delay line 0 unlock</bit>
56 <bit pos="45">RCS - Delay line 1 unlock</bit>
57 <bit pos="46">PIBMEM</bit>
58 <bit pos="47">PIBMEM</bit>
59 <bit pos="48">OTP - Combination of ecc uncorrectable error and correctable error counter overflow - Can be considered as checkstop</bit>
60 <bit pos="49">DPLL_FIR_NEST_DCO_EMPTY</bit>
61 <bit pos="50">DPLL_FIR_NEST_DCO_FULL</bit>
62 <bit pos="51">DPLL_FIR_NEST_INT_ERROR</bit>
63 <bit pos="52">DPLL_FIR_PAU_DCO_EMPTY</bit>
64 <bit pos="53">DPLL_FIR_PAU_DCO_FULL</bit>
65 <bit pos="54">DPLL_FIR_PAU_INT_ERROR</bit>
66 <bit pos="55">SPI Master 0 Err</bit>
67 <bit pos="56">SPI Master 1 Err</bit>
68 <bit pos="57">SPI Master 2 Err</bit>
69 <bit pos="58">SPI Master 3 Err</bit>
70 <bit pos="59">SPI Master 4 Err</bit>
71 <bit pos="60">unused</bit>
72 <bit pos="61">unused</bit>
73 <bit pos="62">unused</bit>
74 <bit pos="63">ext_local_xstop</bit>
75</attn_node>