blob: cac4ae228707c3fde6b33ea5692b899ca074687d [file] [log] [blame]
Zane Shelleyf8a726b2020-12-16 21:29:32 -06001<?xml version="1.0" encoding="UTF-8"?>
2<attn_node model_ec="P10_10" name="MC_FIR" reg_type="SCOM">
3 <local_fir config="W2" name="MC_FIR">
4 <instance addr="0x0C010C00" reg_inst="0"/>
5 <instance addr="0x0D010C00" reg_inst="1"/>
6 <instance addr="0x0E010C00" reg_inst="2"/>
7 <instance addr="0x0F010C00" reg_inst="3"/>
8 <action attn_type="CS" config="000"/>
9 <action attn_type="RE" config="010"/>
10 <action attn_type="SPA" config="100"/>
11 <action attn_type="UCS" config="110"/>
12 <action attn_type="HA" config="001"/>
13 </local_fir>
14 <bit pos="0">If '1', a MC recoverable error was detected. See the MCERPTx register description for a list of errors that cause this FIR to be set.</bit>
15 <bit pos="1">If 1, a MC non-recoverable error was detected. See the MCERPTx register description for a list of errors that cause this FIR to be set.</bit>
16 <bit pos="2">If '1', an PowerBus protocol error was detected. (for example, a HPC_WR is snooped when a HPC_WR to the same address is active).</bit>
17 <bit pos="3">If '1', a command was issued to inband address space using a</bit>
18 <bit pos="4">If '1', an address match on more that one Memory BAR was detected.</bit>
19 <bit pos="5">If set, the ECC syndrome for PowerBus write data is non-zero (for chan0/1 in pbi01, chann2/3 in pbi23)</bit>
20 <bit pos="6">Reserved[6].</bit>
21 <bit pos="7">Reserved[7].</bit>
22 <bit pos="8">If '1', a command list state machine has timed out.</bit>
23 <bit pos="9">Reserved[9].</bit>
24 <bit pos="10">Reserved[10].</bit>
25 <bit pos="11">If '1', a MCS WAT0 event has occurred.</bit>
26 <bit pos="12">If '1', a MCS WAT1 event has occurred.</bit>
27 <bit pos="13">If '1', a MCS WAT2 event has occurred.</bit>
28 <bit pos="14">If '1', a MCS WAT3 event has occurred.</bit>
29 <bit pos="15">Plus One Prefetch generated command did not hit any BARs</bit>
30 <bit pos="16">Plus One Prefetch generated command hit config or mmio BAR</bit>
31 <bit pos="17">Parity Error in WAT/Debug config register.</bit>
32 <bit pos="18">Reserved[18].</bit>
33 <bit pos="19">Reserved[19].</bit>
34 <bit pos="20">Incoming Powerbus Command hit multiple valid configured topology IDs</bit>
35 <bit pos="21">Reserved[21].</bit>
36 <bit pos="22">Access to secure memory facility failed. Improper access privilege by originating thread.</bit>
37 <bit pos="23">Caused by multiple sync commands being received by an MC at a time, or while one is pending</bit>