Zane Shelley | f8a726b | 2020-12-16 21:29:32 -0600 | [diff] [blame^] | 1 | <?xml version="1.0" encoding="UTF-8"?> |
| 2 | <attn_node model_ec="P10_10" name="MC_FIR" reg_type="SCOM"> |
| 3 | <local_fir config="W2" name="MC_FIR"> |
| 4 | <instance addr="0x0C010C00" reg_inst="0"/> |
| 5 | <instance addr="0x0D010C00" reg_inst="1"/> |
| 6 | <instance addr="0x0E010C00" reg_inst="2"/> |
| 7 | <instance addr="0x0F010C00" reg_inst="3"/> |
| 8 | <action attn_type="CS" config="000"/> |
| 9 | <action attn_type="RE" config="010"/> |
| 10 | <action attn_type="SPA" config="100"/> |
| 11 | <action attn_type="UCS" config="110"/> |
| 12 | <action attn_type="HA" config="001"/> |
| 13 | </local_fir> |
| 14 | <bit pos="0">If '1', a MC recoverable error was detected. See the MCERPTx register description for a list of errors that cause this FIR to be set.</bit> |
| 15 | <bit pos="1">If 1, a MC non-recoverable error was detected. See the MCERPTx register description for a list of errors that cause this FIR to be set.</bit> |
| 16 | <bit pos="2">If '1', an PowerBus protocol error was detected. (for example, a HPC_WR is snooped when a HPC_WR to the same address is active).</bit> |
| 17 | <bit pos="3">If '1', a command was issued to inband address space using a</bit> |
| 18 | <bit pos="4">If '1', an address match on more that one Memory BAR was detected.</bit> |
| 19 | <bit pos="5">If set, the ECC syndrome for PowerBus write data is non-zero (for chan0/1 in pbi01, chann2/3 in pbi23)</bit> |
| 20 | <bit pos="6">Reserved[6].</bit> |
| 21 | <bit pos="7">Reserved[7].</bit> |
| 22 | <bit pos="8">If '1', a command list state machine has timed out.</bit> |
| 23 | <bit pos="9">Reserved[9].</bit> |
| 24 | <bit pos="10">Reserved[10].</bit> |
| 25 | <bit pos="11">If '1', a MCS WAT0 event has occurred.</bit> |
| 26 | <bit pos="12">If '1', a MCS WAT1 event has occurred.</bit> |
| 27 | <bit pos="13">If '1', a MCS WAT2 event has occurred.</bit> |
| 28 | <bit pos="14">If '1', a MCS WAT3 event has occurred.</bit> |
| 29 | <bit pos="15">Plus One Prefetch generated command did not hit any BARs</bit> |
| 30 | <bit pos="16">Plus One Prefetch generated command hit config or mmio BAR</bit> |
| 31 | <bit pos="17">Parity Error in WAT/Debug config register.</bit> |
| 32 | <bit pos="18">Reserved[18].</bit> |
| 33 | <bit pos="19">Reserved[19].</bit> |
| 34 | <bit pos="20">Incoming Powerbus Command hit multiple valid configured topology IDs</bit> |
| 35 | <bit pos="21">Reserved[21].</bit> |
| 36 | <bit pos="22">Access to secure memory facility failed. Improper access privilege by originating thread.</bit> |
| 37 | <bit pos="23">Caused by multiple sync commands being received by an MC at a time, or while one is pending</bit> |
| 38 | </attn_node> |