| #pragma once |
| |
| #include "config.h" |
| |
| #ifdef POWER10 |
| #include "occ_command.hpp" |
| |
| #include <cereal/archives/json.hpp> |
| //#include <cereal/archives/binary.hpp> |
| #include <cereal/cereal.hpp> |
| #include <cereal/types/string.hpp> |
| #include <cereal/types/tuple.hpp> |
| #include <cereal/types/vector.hpp> |
| #include <sdbusplus/bus.hpp> |
| #include <sdbusplus/bus/match.hpp> |
| |
| #include <filesystem> |
| |
| namespace open_power |
| { |
| namespace occ |
| { |
| |
| class Manager; |
| |
| namespace powermode |
| { |
| |
| constexpr auto PMODE_PATH = "/xyz/openbmc_project/control/host0/power_mode"; |
| constexpr auto PMODE_INTERFACE = "xyz.openbmc_project.Control.Power.Mode"; |
| constexpr auto POWER_MODE_PROP = "PowerMode"; |
| |
| constexpr auto PIPS_PATH = "/xyz/openbmc_project/control/host0/power_ips"; |
| constexpr auto PIPS_INTERFACE = |
| "xyz.openbmc_project.Control.Power.IdlePowerSaver"; |
| constexpr auto IPS_ENABLED_PROP = "Enabled"; |
| constexpr auto IPS_ENTER_UTIL = "EnterUtilizationPercent"; |
| constexpr auto IPS_ENTER_TIME = "EnterDwellTime"; |
| constexpr auto IPS_EXIT_UTIL = "ExitUtilizationPercent"; |
| constexpr auto IPS_EXIT_TIME = "ExitDwellTime"; |
| |
| /** @brief Query the current Hypervisor target |
| * @return true if the current Hypervisor target is PowerVM |
| */ |
| bool isPowerVM(); |
| |
| /** @brief Convert power mode string to OCC SysPwrMode value |
| * |
| * @param[in] i_modeString - power mode string |
| * |
| * @return SysPwrMode or SysPwrMode::NO_CHANGE if not found |
| */ |
| SysPwrMode convertStringToMode(const std::string& i_modeString); |
| |
| struct OemModeData |
| { |
| SysPwrMode oemMode = SysPwrMode::NO_CHANGE; |
| uint16_t oemModeFreq = 0x0000; |
| |
| /** @brief Function specifying data to archive for cereal. |
| */ |
| template <class Archive> |
| void serialize(Archive& archive) |
| { |
| archive(oemMode, oemModeFreq); |
| } |
| }; |
| |
| /** @class OccPersistData |
| * @brief Provides persistent container to store data for OCC |
| * |
| * Data is stored via cereal |
| */ |
| class OccPersistData |
| { |
| public: |
| ~OccPersistData() = default; |
| OccPersistData(const OccPersistData&) = default; |
| OccPersistData& operator=(const OccPersistData&) = default; |
| OccPersistData(OccPersistData&&) = default; |
| OccPersistData& operator=(OccPersistData&&) = default; |
| |
| /** @brief Loads any saved OEM mode data */ |
| OccPersistData() |
| { |
| load(); |
| } |
| |
| /** @brief Save Power Mode data to persistent file |
| * |
| * @param[in] newMode - desired OEM Power Mode |
| * @param[in] modeData - data required by some OEM Power Modes |
| */ |
| void writeModeFile(const SysPwrMode newMode, const uint16_t modeData) |
| { |
| oemData.oemMode = newMode; |
| oemData.oemModeFreq = modeData; |
| oemSet = true; |
| save(); |
| } |
| |
| /** @brief Return the OEM Power Mode and frequency if enabled |
| * |
| * @param[out] newMode - OEM mode (if set, else data not changed) |
| * @param[out] oemFreq - Frequency data for OEM mode |
| * |
| * @returns true if OEM mode was set |
| */ |
| bool getOemMode(SysPwrMode& mode, uint16_t& freq) const |
| { |
| if (!oemSet) |
| { |
| return false; |
| } |
| |
| mode = oemData.oemMode; |
| freq = oemData.oemModeFreq; |
| return true; |
| } |
| |
| /** @brief Saves the Power Mode data in the filesystem using cereal. */ |
| void save(); |
| |
| /** @brief Removes the OEM mode data. */ |
| void purge(); |
| |
| inline void print(); |
| |
| private: |
| static constexpr auto oemModeFilename = "oemModeData"; |
| |
| /** @brief true if an OEM Power Mode was set */ |
| bool oemSet = false; |
| |
| /** @brief OEM Power Mode data */ |
| OemModeData oemData; |
| |
| /** @brief Loads the OEM mode data in the filesystem using cereal. */ |
| void load(); |
| }; |
| |
| /** @class PowerMode |
| * @brief Monitors for changes to the power mode and notifies occ |
| * |
| * The customer power mode is provided to the OCC by host TMGT when the occ |
| * first goes active or is reset. This code is responsible for sending |
| * the power mode to the OCC if the mode is changed while the occ is active. |
| */ |
| |
| class PowerMode |
| { |
| public: |
| /** @brief PowerMode object to inform occ of changes to mode |
| * |
| * This object will monitor for changes to the power mode setting. |
| * If a change is detected, and the occ is active, then this object will |
| * notify the OCC of the change. |
| * |
| * @param[in] managerRef - |
| * @param[in] path - |
| */ |
| explicit PowerMode(Manager& managerRef, const char* path) : |
| manager(managerRef), path(path), occInstance(this->path.back() - '0'), |
| occCmd(occInstance, path), |
| pmodeMatch(utils::getBus(), |
| sdbusplus::bus::match::rules::propertiesChanged( |
| PMODE_PATH, PMODE_INTERFACE), |
| [this](auto& msg) { this->modeChanged(msg); }), |
| ipsMatch(utils::getBus(), |
| sdbusplus::bus::match::rules::propertiesChanged( |
| PIPS_PATH, PIPS_INTERFACE), |
| [this](auto& msg) { this->ipsChanged(msg); }), |
| masterActive(false){}; |
| |
| bool setMode(const SysPwrMode newMode, const uint16_t modedata); |
| |
| /** @brief Send mode change command to the master OCC |
| * @return SUCCESS on success |
| */ |
| CmdStatus sendModeChange(); |
| |
| /** @brief Send Idle Power Saver config data to the master OCC |
| * @return SUCCESS on success |
| */ |
| CmdStatus sendIpsData(); |
| |
| /** @brief Notify object of master OCC state. If not acitve, no |
| * commands will be sent to the master OCC |
| * |
| * @param[in] isActive - true when master OCC is active |
| */ |
| void setMasterActive(const bool isActive = true) |
| { |
| masterActive = isActive; |
| }; |
| |
| private: |
| /** @brief OCC manager object */ |
| const Manager& manager; |
| |
| /** @brief Pass-through occ path on the bus */ |
| std::string path; |
| |
| /** @brief OCC instance number */ |
| int occInstance; |
| |
| /** @brief Object to send commands to the OCC */ |
| OccCommand occCmd; |
| |
| /** @brief Used to subscribe to dbus pmode property changes **/ |
| sdbusplus::bus::match_t pmodeMatch; |
| |
| /** @brief Used to subscribe to dbus IPS property changes **/ |
| sdbusplus::bus::match_t ipsMatch; |
| |
| OccPersistData persistedData; |
| |
| bool masterActive; |
| |
| /** @brief Callback for pmode setting changes |
| * |
| * Process change and inform OCC |
| * |
| * @param[in] msg - Data associated with pmode change signal |
| * |
| */ |
| void modeChanged(sdbusplus::message::message& msg); |
| |
| /** @brief Get the current power mode property from DBus |
| * @return Power mode |
| */ |
| SysPwrMode getDbusMode(); |
| |
| /** @brief Update the power mode property on DBus |
| * |
| * @param[in] newMode - desired power mode |
| * |
| * @return true on success |
| */ |
| bool updateDbusMode(const SysPwrMode newMode); |
| |
| /** @brief Callback for IPS setting changes |
| * |
| * Process change and inform OCC |
| * |
| * @param[in] msg - Data associated with IPS change signal |
| * |
| */ |
| void ipsChanged(sdbusplus::message::message& msg); |
| |
| /** @brief Get the Idle Power Saver properties from DBus |
| * @return true if IPS is enabled |
| */ |
| bool getIPSParms(uint8_t& enterUtil, uint16_t& enterTime, uint8_t& exitUtil, |
| uint16_t& exitTime); |
| }; |
| |
| } // namespace powermode |
| |
| } // namespace occ |
| |
| } // namespace open_power |