| description: > |
| Implement to provide sensor readings. Objects implementing Sensor.Value |
| must be instantiated in the correct hierarchy within the sensors |
| namespace. The following sensor hierarchies are recognized: |
| airflow |
| altitude |
| current |
| energy |
| fan_tach |
| humidity |
| power |
| pressure |
| temperature |
| utilization |
| voltage |
| |
| Any service implementing Sensor.Value on one or more objects must implement |
| org.freedesktop.DBus.ObjectManager on /xyz/openbmc_project/sensors. |
| |
| All Sensor.Value properties are read-only. |
| |
| properties: |
| - name: Value |
| type: double |
| description: > |
| The sensor reading. |
| - name: MaxValue |
| type: double |
| default: infinity |
| description: > |
| The Maximum supported sensor reading. |
| - name: MinValue |
| type: double |
| default: -infinity |
| description: > |
| The Minimum supported sensor reading. |
| - name: Unit |
| type: enum[self.Unit] |
| description: > |
| The unit of the reading. Immutable once set for a sensor. For objects |
| in the airflow namespace, Unit must be "CFM" For objects in the |
| altitude namespace, Unit must be "Meters". For objects in the current |
| namespace, Unit must be "Amperes". For objects in the energy |
| namespace, Unit must be "Joules". For objects in the fan_tach |
| namespace, Unit must be "RPMS". For objects in the humidity namespace, |
| Unit must be "PercentRH" For objects in the power namespace, Unit must |
| be "Watts". For objects in the pressure namespace, Unit must be |
| "Pascals" For objects in the temperature namespace, Unit must be |
| "DegreesC". For objects in the utilization namespace, Unit must be |
| "Percent" For objects in the voltage namespace, Unit must be "Volts". |
| |
| enumerations: |
| - name: Unit |
| description: > |
| A sensor reading unit. |
| values: |
| - name: Amperes |
| description: > |
| Electrical charge flow rate as Amperes. |
| - name: CFM |
| description: > |
| To calculate Air Flow in Cubic Feet per Minute |
| - name: DegreesC |
| description: > |
| Temperature as degrees Celsius. |
| - name: Joules |
| description: > |
| Energy transfer as Joules. |
| - name: Meters |
| description: > |
| Length as meters. |
| - name: Percent |
| description: > |
| Resource utilization as a percentage. |
| - name: PercentRH |
| description: > |
| Relative humidity as a percentage. |
| - name: Pascals |
| description: > |
| Pressure as pascals. |
| - name: RPMS |
| description: > |
| Frequency of rotation as revolutions per minute. |
| - name: Volts |
| description: > |
| Electomotive force as volts. |
| - name: Watts |
| description: > |
| Rate of energy transfer as Watts. |
| |
| associations: |
| - name: inventory |
| description: > |
| Sensors may implement an 'inventory' to 'sensors' association with the |
| inventory item related to it. |
| reverse_names: |
| - sensors |
| required_endpoint_interfaces: |
| - xyz.openbmc_project.Inventory.Item |
| - name: monitoring |
| description: > |
| Sensors may monitor the BMC's resource utilization and implement an |
| association to the Bmc item. |
| reverse_names: |
| - monitored_by |
| required_endpoint_interfaces: |