blob: 43e188294bab84220d8062df6f16c9ccfec7fd3b [file] [log] [blame]
version: 1.1.0
errors:
- name: DeviceOverOperatingTemperature
severity: error
metadata:
- name: Device
type: object_path
primary: true
description: The name or identifier of the device
- name: FailureData
type: string
description:
An [Optional] set of additional failure data to identify the
cause of thermal overrun.
en:
description:
A event signaling that a device is operating over a set operating
temperature has occurred. The device may continue to operate in a
potentially performance degraded mode. This is very similar to the
PROCHOT signal from some x86 processors.
message: Device {Device} is over safe operating temperature.
errno: ERANGE
- name: DeviceOverOperatingTemperatureFault
severity: critical
metadata:
- name: Device
type: object_path
primary: true
description: The name or identifier of the device
- name: FailureData
type: string
description:
An [Optional] set of additional failure data to identify the
cause of thermal overrun fault.
en:
description:
A event signaling that a device has potentially been powered off
due to it operating significantly in excess of the set operating
temperature. This is very similar to the THERMTRIP signal from
some x86 processors.
message:
Device {Device} is significantly over safe operating temperature
and may have been powered off.
errno: ERANGE
events:
- name: DeviceOperatingNormalTemperature
metadata:
- name: Device
type: object_path
primary: true
description: The name or identifier of the device
en:
description:
A event signaling that a device is operating over a set operating
temperature has cleared.
message: Device {Device} is operating in normal temperature.