| description: > |
| An interface to set whether the power supplies are redundant. |
| properties: |
| - name: PowerSupplyRedundancyEnabled |
| type: boolean |
| flags: |
| - const |
| description: > |
| When true, the power supplies are redundant. |
| - name: RotationEnabled |
| type: boolean |
| description: > |
| Cold redundancy rotation enabled or not. |
| - name: RotationAlgorithm |
| type: enum[self.Algo] |
| description: > |
| Rotation algorithm use for cold redundancy. 0 is BMC Specific, 1 is User |
| Specific. |
| - name: RotationRankOrder |
| type: array[byte] |
| description: > |
| The rank order for each PSU, 0 means will not go into cold standby |
| state. |
| - name: PeriodOfRotation |
| type: uint32 |
| description: > |
| Rotation Period for cold redundancy. If rotation algorithm is BMC |
| Specific, and rotation is enabled, BMC will change PSU rank order after |
| this time. The unit of this PeriodOfRotation is in seconds. |
| - name: ColdRedundancyStatus |
| type: enum[self.Status] |
| description: > |
| Cold redundancy setting status, set in progress or set completed. |
| - name: PSUNumber |
| type: byte |
| description: > |
| Number of PSUs are currently on system. |
| - name: RedundantCount |
| type: byte |
| description: > |
| The min number of PSUs in the system required to obtain redundancy |
| default: 2 |
| |
| enumerations: |
| - name: Algo |
| description: > |
| Rotation algorithm use for cold redundancy. |
| values: |
| - name: bmcSpecific |
| description: > |
| With BMC Specific algorithm, when rotation happen, BMC will add 1 to |
| the rank order in each PSU and change the last rank order to the |
| first rank order. |
| - name: userSpecific |
| description: > |
| With User Specific algorithm, user need to set the RotationRankOrder |
| every time before rotation happen, then BMC will update the rank |
| order to PSU. |
| - name: Status |
| description: > |
| Cold redundancy setting status. |
| values: |
| - name: inProgress |
| description: > |
| This status is only use for multi-node system, after any of the |
| property setting on one node, before all the nodes sync to same |
| value, the status will show in progress. |
| - name: completed |
| description: > |
| For single ndoe system, the status always keep show completed. For |
| multi-node system, only after all the nodes sync to same value of |
| the properties, the status will be completed. |