description: >
An interface to set whether the power supplies are redundant.
properties:
- name: PowerSupplyRedundancyEnabled
type: boolean
flags:
- const
description: >
When true, the power supplies are redundant.
- name: RotationEnabled
type: boolean
description: >
Cold redundancy rotation enabled or not.
- name: RotationAlgorithm
type: enum[self.Algo]
description: >
Rotation algorithm use for cold redundancy. 0 is BMC Specific, 1 is User
Specific.
- name: RotationRankOrder
type: array[byte]
description: >
The rank order for each PSU, 0 means will not go into cold standby
state.
- name: PeriodOfRotation
type: uint32
description: >
Rotation Period for cold redundancy. If rotation algorithm is BMC
Specific, and rotation is enabled, BMC will change PSU rank order after
this time. The unit of this PeriodOfRotation is in seconds.
- name: ColdRedundancyStatus
type: enum[self.Status]
description: >
Cold redundancy setting status, set in progress or set completed.
- name: PSUNumber
type: byte
description: >
Number of PSUs are currently on system.
- name: RedundantCount
type: byte
description: >
The min number of PSUs in the system required to obtain redundancy
default: 2
enumerations:
- name: Algo
description: >
Rotation algorithm use for cold redundancy.
values:
- name: bmcSpecific
description: >
With BMC Specific algorithm, when rotation happen, BMC will add 1 to
the rank order in each PSU and change the last rank order to the
first rank order.
- name: userSpecific
description: >
With User Specific algorithm, user need to set the RotationRankOrder
every time before rotation happen, then BMC will update the rank
order to PSU.
- name: Status
description: >
Cold redundancy setting status.
values:
- name: inProgress
description: >
This status is only use for multi-node system, after any of the
property setting on one node, before all the nodes sync to same
value, the status will show in progress.
- name: completed
description: >
For single ndoe system, the status always keep show completed. For
multi-node system, only after all the nodes sync to same value of
the properties, the status will be completed.