blob: 0846e70db3479891cecd82d4e06359fef104dfbc [file] [log] [blame]
tony lee57b878d2019-03-22 21:18:23 +08001description: >
2 Interface to get Nvme info.
3properties:
4 - name: SmartWarnings
5 type: string
6 description: >
7 Indicates smart warnings for the state.
8 - name: StatusFlags
9 type: string
10 description: >
11 Indicates the status of the drives.
12 - name: DriveLifeUsed
13 type: string
14 description: >
15 A vendor specific estimate of the percentage.
16 - name: CapacityFault
17 type: boolean
18 default: false
19 description: >
20 Represent the available spare capacity has fallen below the threshold.
21 - name: TemperatureFault
22 type: boolean
23 default: false
24 description: >
Patrick Williamsa1347412022-12-06 10:56:22 -060025 Represent a temperature is above an over temperature threshold or
26 below an under temperature threshold
tony lee57b878d2019-03-22 21:18:23 +080027 - name: DegradesFault
28 type: boolean
29 default: false
30 description: >
31 Represent the NVM subsystem reliability has been degraded due to
Patrick Williamsa1347412022-12-06 10:56:22 -060032 significant media related errors or any internal error that degrades
33 NVM subsystem reliability
tony lee57b878d2019-03-22 21:18:23 +080034 - name: MediaFault
35 type: boolean
36 default: false
37 description: >
38 Represent the media has been placed in read only mode
39 - name: BackupDeviceFault
40 type: boolean
41 default: false
42 description: >
43 Represent the volatile memory backup device has failed.