Patrick Williams | 3350f3e | 2016-11-23 07:27:01 -0600 | [diff] [blame] | 1 | description: > |
| 2 | Activation state for an associated xyz.openbmc_project.Software.Version. |
| 3 | properties: |
| 4 | - name: Activation |
| 5 | type: enum[self.Activations] |
| 6 | description: > |
| 7 | The current Activation state of the Software.Version. |
| 8 | - name: RequestedActivation |
| 9 | type: enum[self.RequestedActivations] |
| 10 | description: > |
| 11 | The desired Activation state of the Software.Version. |
| 12 | enumerations: |
| 13 | - name: Activations |
| 14 | description: > |
| 15 | The possible Activation states of the Software.Version. |
| 16 | values: |
| 17 | - name: NotReady |
| 18 | description: > |
| 19 | The system is still analyzing the Software.Version and is |
| 20 | currently unable to activate. |
| 21 | - name: Invalid |
| 22 | description: > |
| 23 | The Software.Version is invalid and unable to be activated. |
| 24 | - name: Ready |
| 25 | description: > |
| 26 | The Software.Version has been processed and is ready for |
| 27 | Activation. |
| 28 | - name: Activating |
| 29 | description: > |
| 30 | The Software.Version is in the process of being Activated. |
| 31 | - name: Active |
| 32 | description: > |
| 33 | The Software.Version is currently Active. |
| 34 | - name: Failed |
| 35 | description: > |
| 36 | The Software.Version failed during or after Activation. |
Vikram Bodireddy | 548d3e9 | 2020-01-06 21:40:40 +0530 | [diff] [blame] | 37 | - name: Staged |
| 38 | description: > |
| 39 | The Software.Version is currently in staged flash area. |
| 40 | This is moved from staged flash area to active upon reset. |
Patrick Williams | 3350f3e | 2016-11-23 07:27:01 -0600 | [diff] [blame] | 41 | - name: RequestedActivations |
| 42 | description: > |
| 43 | The possible RequestedActivation states of a Software.Version. |
| 44 | values: |
| 45 | - name: None |
| 46 | description: > |
| 47 | No action has been directed for this Software.Version. |
| 48 | - name: Active |
| 49 | description: > |
| 50 | The Software.Version has been requested for Activation. |
| 51 | # TODO: Specify "EAGAIN" type error when requested is unable to be acted on |
| 52 | # due to current system state. Currently, sdbusplus does not support |
| 53 | # errors on properties. |