Shawn McCarney | 54ed0a1 | 2021-12-08 11:14:46 -0600 | [diff] [blame] | 1 | description: > |
| 2 | "org.freedesktop.UPower.Device -- Device interface |
| 3 | Defined at https://upower.freedesktop.org/docs/Device.html |
| 4 | Objects implementing org.freedesktop.UPower.Device also implement the |
| 5 | org.freedesktop.DBus.Introspectable and org.freedesktop.DBus.Properties |
| 6 | interfaces. Unless otherwise noted, an empty string or the value 0 in a |
| 7 | property on this interface means not set." |
| 8 | |
| 9 | methods: |
| 10 | - name: Refresh |
| 11 | description: > |
| 12 | "Refreshes the data collected from the power source. Callers need the |
| 13 | org.freedesktop.upower.refresh-power-source authorization" |
| 14 | |
| 15 | - name: GetHistory |
| 16 | description: > |
| 17 | "Gets history for the power device that is persistent across |
| 18 | reboots." |
| 19 | parameters: |
| 20 | - name: type |
| 21 | type: string |
| 22 | description: > |
| 23 | "The type of history. Valid types are rate or charge." |
| 24 | - name: timespan |
| 25 | type: uint32 |
| 26 | description: > |
| 27 | "The amount of data to return in seconds, or 0 for all." |
| 28 | - name: resolution |
| 29 | type: uint32 |
| 30 | description: > |
| 31 | "The approximate number of points to return. A higher resolution is |
| 32 | more accurate, at the expense of plotting speed." |
| 33 | returns: |
| 34 | - name: data |
| 35 | type: array[struct[uint32, double, uint32]] |
| 36 | description: > |
| 37 | "The history data for the power device, if the device supports |
| 38 | history. Data is ordered from the earliest in time, to the newest |
| 39 | data point. Each element contains the following members: |
| 40 | time: The time value in seconds from the gettimeofday() method. |
| 41 | value: The data value, for instance the rate in W or the charge |
| 42 | in %. |
| 43 | state: The state of the device, for instance charging or |
| 44 | discharging." |
| 45 | |
| 46 | - name: GetStatistics |
| 47 | description: > |
| 48 | "Gets statistics for the power device that may be interesting to show |
| 49 | on a graph in the session." |
| 50 | parameters: |
| 51 | - name: type |
| 52 | type: string |
| 53 | description: > |
| 54 | "The mode for the statistics. Valid types are charging or |
| 55 | discharging." |
| 56 | returns: |
| 57 | - name: data |
| 58 | type: array[struct[double, double]] |
| 59 | description: > |
| 60 | "The statistics data for the power device. Each element contains the |
| 61 | following members: |
| 62 | value: The value of the percentage point, usually in seconds. |
| 63 | accuracy: The accuracy of the prediction in percent." |
| 64 | |
| 65 | properties: |
| 66 | - name: NativePath |
| 67 | default: "" |
| 68 | type: string |
| 69 | description: > |
| 70 | "OS specific native path of the power source. On Linux this is the |
| 71 | sysfs path, for example |
| 72 | /sys/devices/LNXSYSTM:00/device:00/PNP0C0A:00/power_supply/BAT0. Is |
| 73 | blank if the device is being driven by a user space driver." |
| 74 | - name: Vendor |
| 75 | default: "" |
| 76 | type: string |
| 77 | description: > |
| 78 | "Name of the vendor of the battery." |
| 79 | - name: Model |
| 80 | default: "" |
| 81 | type: string |
| 82 | description: > |
| 83 | "Name of the model of this battery." |
| 84 | - name: Serial |
| 85 | default: "" |
| 86 | type: string |
| 87 | description: > |
| 88 | "Unique serial number of the battery." |
| 89 | - name: UpdateTime |
| 90 | default: 0 |
| 91 | type: uint64 |
| 92 | description: > |
| 93 | "The point in time (seconds since the Epoch Jan 1, 1970 0:00 UTC) |
| 94 | that data was read from the power source." |
| 95 | - name: Type |
| 96 | default: 0 |
| 97 | type: uint32 |
| 98 | description: > |
| 99 | "Type of power source. |
| 100 | 0: Unknown |
| 101 | 1: Line Power |
| 102 | 2: Battery |
| 103 | 3: Ups |
| 104 | 4: Monitor |
| 105 | 5: Mouse |
| 106 | 6: Keyboard |
| 107 | 7: Pda |
| 108 | 8: Phone" |
| 109 | - name: PowerSupply |
| 110 | default: false |
| 111 | type: boolean |
| 112 | description: > |
| 113 | "If the power device is used to supply the system. This would be set |
| 114 | TRUE for laptop batteries and UPS devices, but set FALSE for wireless |
| 115 | mice or PDAs." |
| 116 | - name: HasHistory |
| 117 | default: false |
| 118 | type: boolean |
| 119 | description: > |
| 120 | "If the power device has history." |
| 121 | - name: HasStatistics |
| 122 | default: false |
| 123 | type: boolean |
| 124 | description: > |
| 125 | "If the power device has statistics." |
| 126 | - name: Online |
| 127 | default: false |
| 128 | type: boolean |
| 129 | description: > |
| 130 | "Whether power is currently being provided through line power. This |
| 131 | property is only valid if the property type has the value |
| 132 | 'line-power'." |
| 133 | - name: Energy |
| 134 | default: 0.0 |
| 135 | type: double |
| 136 | description: > |
| 137 | "Amount of energy (measured in Wh) currently available in the power |
| 138 | source. This property is only valid if the property type has the |
| 139 | value 'battery'." |
| 140 | - name: EnergyEmpty |
| 141 | default: 0.0 |
| 142 | type: double |
| 143 | description: > |
| 144 | "Amount of energy (measured in Wh) in the power source when it's |
| 145 | considered to be empty. This property is only valid if the property |
| 146 | type has the value 'battery'." |
| 147 | - name: EnergyFull |
| 148 | default: 0.0 |
| 149 | type: double |
| 150 | description: > |
| 151 | "Amount of energy (measured in Wh) in the power source when it's |
| 152 | considered full. This property is only valid if the property type |
| 153 | has the value 'battery'." |
| 154 | - name: EnergyFullDesign |
| 155 | default: 0.0 |
| 156 | type: double |
| 157 | description: > |
| 158 | "Amount of energy (measured in Wh) the power source is designed to |
| 159 | hold when it's considered full. This property is only valid if the |
| 160 | property type has the value 'battery'." |
| 161 | - name: EnergyRate |
| 162 | default: 0.0 |
| 163 | type: double |
| 164 | description: > |
| 165 | "Amount of energy being drained from the source, measured in W. If |
| 166 | positive, the source is being discharged, if negative it's being |
| 167 | charged. This property is only valid if the property type has the |
| 168 | value 'battery'." |
| 169 | - name: Voltage |
| 170 | default: 0.0 |
| 171 | type: double |
| 172 | description: > |
| 173 | "Voltage in the Cell or being recorded by the meter." |
| 174 | - name: Luminosity |
| 175 | default: 0.0 |
| 176 | type: double |
| 177 | description: > |
| 178 | "Luminosity being recorded by the meter." |
| 179 | - name: TimeToEmpty |
| 180 | default: 0 |
| 181 | type: int64 |
| 182 | description: > |
| 183 | "Number of seconds until the power source is considered empty. Is set |
| 184 | to 0 if unknown. This property is only valid if the property type |
| 185 | has the value 'battery'." |
| 186 | - name: TimeToFull |
| 187 | default: 0 |
| 188 | type: int64 |
| 189 | description: > |
| 190 | "Number of seconds until the power source is considered full. Is set |
| 191 | to 0 if unknown. This property is only valid if the property type |
| 192 | has the value 'battery'." |
| 193 | - name: Percentage |
| 194 | default: 0.0 |
| 195 | type: double |
| 196 | description: > |
| 197 | "The amount of energy left in the power source expressed as a |
| 198 | percentage between 0 and 100. Typically this is the same as (energy - |
| 199 | energy-empty) / (energy-full - energy-empty). However, some primitive |
| 200 | power sources are capable of only reporting percentages and in this |
| 201 | case the energy-* properties will be unset while this property is |
| 202 | set. This property is only valid if the property type has the value |
| 203 | 'battery'." |
| 204 | - name: Temperature |
| 205 | default: 0.0 |
| 206 | type: double |
| 207 | description: > |
| 208 | "The temperature of the device in degrees Celsius. This property is |
| 209 | only valid if the property type has the value 'battery'." |
| 210 | - name: IsPresent |
| 211 | default: false |
| 212 | type: boolean |
| 213 | description: > |
| 214 | "If the power source is present in the bay. This field is required as |
| 215 | some batteries are hot-removable, for example expensive UPS and most |
| 216 | laptop batteries. This property is only valid if the property type |
| 217 | has the value 'battery'." |
| 218 | - name: State |
| 219 | default: 0 |
| 220 | type: uint32 |
| 221 | description: > |
| 222 | "The battery power state. |
| 223 | 0: Unknown |
| 224 | 1: Charging |
| 225 | 2: Discharging |
| 226 | 3: Empty |
| 227 | 4: Fully charged |
| 228 | 5: Pending charge |
| 229 | 6: Pending discharge |
| 230 | This property is only valid if the property type has the value |
| 231 | 'battery'." |
| 232 | - name: IsRechargeable |
| 233 | default: false |
| 234 | type: boolean |
| 235 | description: > |
| 236 | "If the power source is rechargeable. This property is only valid if |
| 237 | the property type has the value 'battery'." |
| 238 | - name: Capacity |
| 239 | default: 0.0 |
| 240 | type: double |
| 241 | description: > |
| 242 | "The capacity of the power source expressed as a percentage between 0 |
| 243 | and 100. The capacity of the battery will reduce with age. A capacity |
| 244 | value less than 75% is usually a sign that you should renew your |
| 245 | battery. Typically this value is the same as (full-design / full) * |
| 246 | 100. However, some primitive power sources are not capable reporting |
| 247 | capacity and in this case the capacity property will be unset. This |
| 248 | property is only valid if the property type has the value 'battery'." |
| 249 | - name: Technology |
| 250 | default: 0 |
| 251 | type: uint32 |
| 252 | description: > |
| 253 | "Technology used in the battery: |
| 254 | 0: Unknown |
| 255 | 1: Lithium ion |
| 256 | 2: Lithium polymer |
| 257 | 3: Lithium iron phosphate |
| 258 | 4: Lead acid |
| 259 | 5: Nickel cadmium |
| 260 | 6: Nickel metal hydride |
| 261 | This property is only valid if the property type has the value |
| 262 | 'battery'." |
| 263 | - name: WarningLevel |
| 264 | default: 0 |
| 265 | type: uint32 |
| 266 | description: > |
| 267 | "Warning level of the battery: |
| 268 | 0: Unknown |
| 269 | 1: None |
| 270 | 2: Discharging (only for UPSes) |
| 271 | 3: Low |
| 272 | 4: Critical |
| 273 | 5: Action" |
| 274 | - name: BatteryLevel |
| 275 | default: 0 |
| 276 | type: uint32 |
| 277 | description: > |
| 278 | "Level of the battery: |
| 279 | 0: Unknown |
| 280 | 1: None (the battery does not use a coarse level of battery reporting) |
| 281 | 3: Low |
| 282 | 4: Critical |
| 283 | 6: Normal |
| 284 | 7: High |
| 285 | 8: Full" |
| 286 | - name: IconName |
| 287 | default: "" |
| 288 | type: string |
| 289 | description: > |
| 290 | "An icon name, following the Icon Naming Specification" |