blob: fbb6d7845105f55e48a58428f09be1aa9ce0082a [file] [log] [blame]
Matt Spinler45ed88d2020-11-20 11:33:16 -06001description: >
2
3 Implement to provide hard shutdown class sensor thresholds. Objects
4 implementing Sensor.Threshold.HardShutdown must be instantiated in the
5 correct hierarchy within the sensors namespace. The following sensor
6 hierarchies are recognized:
7 temperature
8 fan_tach
9 voltage
10 altitude
11 current
12 power
13 energy
Patrick Williams86f8c532021-10-01 06:34:04 -050014 utilization
15 airflow
16 pressure
Matt Spinler45ed88d2020-11-20 11:33:16 -060017
18 Additionally, any object implementing Sensor.Threshold.HardShutdown must
19 also implement Sensor.Value.
20
21properties:
22 - name: HardShutdownHigh
23 type: double
24 default: NaN
25 description: >
26 The upper bound of the shutdown threshold. A value of 'NaN' is used
27 to indicate there is no threshold of this type.
28 - name: HardShutdownLow
29 type: double
30 default: NaN
31 description: >
32 The lower bound of the shutdown threshold. A value of 'NaN' is used
33 to indicate there is no threshold of this type.
34 - name: HardShutdownAlarmHigh
35 type: boolean
36 description: >
37 True if the sensor value has exceeded the defined bound.
38 False if the sensor value has not exceeded the defined bound.
39
40 HardShutdownAlarmHigh may be set to False to clear an alarm condition.
41 The behavior of setting HardShutdownAlarmHigh to True is undefined.
42 - name: HardShutdownAlarmLow
43 type: boolean
44 description: >
45 True if the sensor value has exceeded the defined bound.
46 False if the sensor value has not exceeded the defined bound.
47
48 HardShutdownAlarmLow may be set to False to clear an alarm condition.
49 The behavior of setting HardShutdownAlarmLow to True is undefined.
Matt Spinler70ee1cf2021-01-21 15:25:59 -060050
51signals:
52 - name: HardShutdownHighAlarmAsserted
53 description: >
54 The high threshold alarm asserted.
55 properties:
56 - name: SensorValue
57 type: double
58 description: >
59 The sensor value that triggered the alarm change.
60 - name: HardShutdownHighAlarmDeasserted
61 description: >
62 The high threshold alarm deasserted.
63 properties:
64 - name: SensorValue
65 type: double
66 description: >
67 The sensor value that triggered the alarm change.
68 - name: HardShutdownLowAlarmAsserted
69 description: >
70 The low threshold alarm asserted.
71 properties:
72 - name: SensorValue
73 type: double
74 description: >
75 The sensor value that triggered the alarm change.
76 - name: HardShutdownLowAlarmDeasserted
77 description: >
78 The low threshold alarm deasserted.
79 properties:
80 - name: SensorValue
81 type: double
82 description: >