Vijay Lobo | 8c71ba7 | 2021-06-24 23:37:30 -0500 | [diff] [blame] | 1 | description: > |
| 2 | Implement to provide PEL event/error entry attributes. |
| 3 | properties: |
| 4 | - name: Hidden |
| 5 | type: boolean |
| 6 | default: false |
| 7 | description: > |
Patrick Williams | 8da396c | 2022-03-14 14:21:02 -0500 | [diff] [blame] | 8 | Hidden Error - This flag allows events to be placed in a system, but |
| 9 | remain hidden from the customer. This event log is visible to |
| 10 | development personnel only, e.g. hardware recovered error, etc. No |
| 11 | service action is required for this type of errors. In general, when |
| 12 | this value is used, the Error Action Flags has the value of |
| 13 | "Hidden Error". An event log with this value is used primarily for |
| 14 | error thresholding design/code debug or as a record to indicate an |
| 15 | error frequency or trend. |
Vijay Lobo | 8c71ba7 | 2021-06-24 23:37:30 -0500 | [diff] [blame] | 16 | - name: Subsystem |
| 17 | type: string |
| 18 | description: > |
Patrick Williams | 8da396c | 2022-03-14 14:21:02 -0500 | [diff] [blame] | 19 | A free form, implementation defined string which uniquely and |
| 20 | permanently identifies a specific subsystem string. This field should |
| 21 | not be used for programmatic interrogation of an object. |
Vijay Lobo | 3e9aa3b | 2021-08-11 17:24:53 -0500 | [diff] [blame] | 22 | - name: ManagementSystemAck |
| 23 | type: boolean |
| 24 | default: false |
| 25 | description: > |
Patrick Williams | 8da396c | 2022-03-14 14:21:02 -0500 | [diff] [blame] | 26 | Notifies the PEL handler that the management system acknowledged a PEL. |
| 27 | The management system can be any system monitoring the hardware. |