Willy Tu | c710b97 | 2021-08-11 16:33:43 -0700 | [diff] [blame] | 1 | |
| 2 | option('tests', type: 'feature', description: 'Build tests') |
| 3 | option('boot-flag-safe-mode-support', type: 'feature', description: 'Add option to enable/disable safe mode in boot flags') |
| 4 | option('i2c-whitelist-check', type: 'feature', description: 'Add option to enable/disable i2c master write read command white list checking') |
| 5 | |
| 6 | # SoftPowerOff |
| 7 | option('softoff', type: 'feature', description: 'Builds soft power off') |
| 8 | option('softoff-busname', type: 'string', value: 'xyz.openbmc_project.Ipmi.Internal.SoftPowerOff', description: 'The Dbus busname to own for SoftPowerOff') |
| 9 | option('softoff-objpath', type: 'string', value: '/xyz/openbmc_project/ipmi/internal/soft_power_off', description: 'The SoftPowerOff Dbus root') |
| 10 | option('ipmi-sms-atn-ack-timeout-secs', type: 'integer', value: 3, description: 'Timeout for host to ack and query SMS_ATN from BMC') |
| 11 | option('ipmi-host-shutdown-complete-timeout-secs', type: 'integer', value: 2700, description: 'Wait time for host to shutdown') |
| 12 | # Indicates an in-band power off or reboot request from the host |
| 13 | # This file is used to ensure the soft off service does not run for host |
| 14 | # initiated shutdown or reboot requests |
| 15 | option('host-inband-request-dir', type: 'string', value: '/run/openbmc/', description: 'Directory to store host initiated shutdown file') |
| 16 | option('host-inband-request-file', type: 'string', value: 'host@%u-request', description: 'File to create if host has initiated shutdown or reboot') |
| 17 | |
| 18 | |
| 19 | # Config Variables |
| 20 | option('board-sensor', type: 'string', value: '/xyz/openbmc_project/inventory/system/chassis/motherboard', description: 'The inventory path to the motherboard fault sensor') |
| 21 | option('system-sensor', type: 'string', value: '/xyz/openbmc_project/inventory/system', description: 'The inventory path to the system event sensor') |
| 22 | |
| 23 | # Control Host Interfaces |
| 24 | option('control-host-busname', type: 'string', value: 'xyz.openbmc_project.Control.Host', description: 'The Control Host Dbus busname to own') |
| 25 | option('control-host-obj-mgr', type: 'string', value: '/xyz/openbmc_project/control', description: 'The Control Host D-Bus Object Manager') |
| 26 | option('host-name', type: 'string', value: 'host', description: 'The Control Host D-Bus Object Manager') |
| 27 | |
| 28 | # Power reading sensor configuration file |
| 29 | option('power-reading-sensor', type: 'string', value: '/usr/share/ipmi-providers/power_reading.json', description: 'Power reading sensor configuration file') |
| 30 | option('host-ipmi-lib-path', type: 'string', value: '/usr/lib/ipmid-providers/', description: 'The file path to search for libraries') |
| 31 | |
| 32 | # When a sensor read fails, hwmon will update the OperationalState interface's Functional property. |
| 33 | # This will mark the sensor as not functional and we will skip reading from that sensor. |
| 34 | option('update-functional-on-fail', type: 'feature', value: 'disabled', description: 'Check functional property to skip reading from faulty sensors') |
| 35 | |
| 36 | # Features |
| 37 | |
| 38 | # When libuserlayer is disabled, libuserlayer won't be included in the build. |
| 39 | option('libuserlayer', type: 'feature', description: 'Option to exclue exclude libuserlayer') |
| 40 | |
| 41 | # When transport-oem is enabled, the transporthandler_oem.cpp contents |
| 42 | # are compiled and added to the project. The transporthandler_oem.cpp file is |
| 43 | # copied from your own customization layer in the |
| 44 | # phosphor-ipmi-host_%.bbappend file. It is not necessary to create this file |
| 45 | # unless OEM Parameter extensions are required. |
| 46 | option('transport-oem', type: 'feature', value: 'disabled', description: 'Enable transporthandler_oem contents') |
| 47 | |
| 48 | # IPMI whitelist mechanism is not needed by everyone; offer a way to disable it |
| 49 | option('ipmi-whitelist', type: 'feature', description: 'Enable/disable IPMI whitelist filtering') |
| 50 | option('whitelist-conf', type: 'string', value: 'host-ipmid-whitelist.conf', description: 'Paths to IPMI whitelisted commands conf files') |
| 51 | |
| 52 | # Dynamic Sensor Stack |
| 53 | option('dynamic-sensors', type: 'feature', value: 'disabled', description: 'Dynamic sensors stack is enabled by default; offer a way to disable it') |
| 54 | option('dynamic-sensors-write', type: 'feature', value: 'disabled', description: 'Dynamic sensors stack is enabled by default; offer a way to disable it') |
| 55 | option('hybrid-sensors', type: 'feature', value: 'disabled', description: 'Hybrid sensors stack is disabled by default; offer a way to enable it') |
| 56 | |
| 57 | # Sensor Cache |
| 58 | option('sensors-cache', type: 'feature', value: 'disabled', description: 'Sensor cache stack is disabled by default; offer a way to enable it') |
| 59 | |
| 60 | # SEL Logger |
| 61 | option('sel-logger-clears-sel', type: 'feature', value: 'disabled', description: 'Clearing SEL through sel-logger is disabled by default; offer a way to enable it') |
| 62 | |
| 63 | # Generate configuration from Yaml |
| 64 | option('sensor-yaml-gen', type: 'string', value: 'sensor-example.yaml') |
| 65 | option('invsensor-yaml-gen', type: 'string', value: 'inventory-sensor-example.yaml') |
| 66 | option('fru-yaml-gen', type: 'string', value: 'fru-read-example.yaml') |
Willy Tu | b78184e | 2022-10-27 22:57:38 +0000 | [diff] [blame] | 67 | |
| 68 | # Software Version |
| 69 | option('get-dbus-active-software', type: 'feature', description: 'Use the getActiveSoftwareVersionInfo for the BMC version and dev_id.json as backup') |