blob: 932c6d1078edada45a2a5b1bc9e27dcf8d8f07cd [file] [log] [blame]
{
"PELs":
[
{
"Name": "xyz.openbmc_project.Common.Error.Timeout",
"Subsystem": "bmc_firmware",
"SRC":
{
"ReasonCode": "0x1001",
"Words6To9":
{
"6":
{
"Description": "Timeout in ms",
"AdditionalDataPropSource": "TIMEOUT_IN_MSEC"
}
}
},
"Documentation":
{
"Description": "This is a generic timeout error",
"Message": "An operation timed out",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.InternalFailure",
"Subsystem": "bmc_firmware",
"SRC":
{
"ReasonCode": "0x1002",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "BMC code had a generic internal failure",
"Message": "An application had an internal failure",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.InvalidArgument",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1003",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "BMC code was given an invalid argument",
"Message": "Code was given an invalid argument",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.InsufficientPermission",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1004",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "An operation failed due to insufficient permission",
"Message": "An operation failed due to unsufficient permission",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.NotAllowed",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1005",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "An operation failed because it isn't allowed",
"Message": "An operation failed because it isn't allowed",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.NoCACertificate",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1006",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "The server's CA certificate has not been provided",
"Message": "The server's CA certificate has not been provided"
}
},
{
"Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x1007",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Sensor device read failure",
"Message": "There was a failure when reading a sensor device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH."
]
}
},
{
"Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x1008",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Device read failure",
"Message": "There was a failure when reading a hardware device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH."
]
}
},
{
"Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x1009",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Device write failure",
"Message": "There was a failure when writing to a hardware device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x100A",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Device write failure",
"Message": "There was a failure when writing to a hardware device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH"
]
}
},
{
"Name": "org.open_power.Logging.Error.SentBadPELToHost",
"Subsystem": "bmc_firmware",
"Severity": "non_error",
"SRC":
{
"ReasonCode": "0x2001",
"Words6To9":
{
"6":
{
"Description": "The bad PEL ID",
"AdditionalDataPropSource": "BAD_ID"
}
}
},
"Documentation":
{
"Description": "The BMC sent the host a malformed PEL",
"Message": "The BMC sent the host a malformed PEL",
"Notes": [
"The host firmware rejected that PEL."
]
}
},
{
"Name": "org.open_power.Logging.Error.BadHostPEL",
"Subsystem": "platform_firmware",
"Severity": "unrecoverable",
"SRC":
{
"ReasonCode": "0x2002",
"Words6To9":
{
"6":
{
"Description": "The PLID of the invalid PEL",
"AdditionalDataPropSource": "PLID"
},
"7":
{
"Description": "The corresponding OpenBMC event log ID",
"AdditionalDataPropSource": "OBMC_LOG_ID"
},
"8":
{
"Description": "The size of the invalid PEL",
"AdditionalDataPropSource": "PEL_SIZE"
}
}
},
"Documentation":
{
"Description": "The host sent the BMC an invalid PEL",
"Message": "The host sent the BMC an invalid PEL",
"Notes": [
]
}
},
{
"Name": "org.open_power.Logging.Error.TestError1",
"Subsystem": "platform_firmware",
"Severity": "unrecoverable",
"SRC":
{
"ReasonCode": "0x2003",
"Words6To9":
{
}
},
"Callouts": [
{
"CalloutList": [
{"Priority": "high", "Procedure": "bmc_code"},
{"Priority": "medium", "SymbolicFRU": "service_docs"}
]
}
],
"Documentation":
{
"Description": "An error for testing",
"Message": "This is a test error"
}
},
{
"Name": "xyz.openbmc_project.Logging.Error.Default",
"Subsystem": "other_na",
"SRC":
{
"ReasonCode": "0x2004",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "This entry is used when no other matching entry is found",
"Message": "Unknown (Original event not in message registry)",
"Notes": [
"This is used when the actual error name isn't found in ",
"the registry. The original error name will be stored ",
"in the UserData section that contains the AdditionalData ",
"properties using the key ERROR_NAME.",
"This error may contain callouts if the creator passed ",
"them in.",
"The severity is set by the creator.",
"If this error is seen, then a code change needs to be ",
"made to add the missing error entry to this registry."
]
}
},
{
"Name": "org.open_power.PHAL.Error.Boot",
"Subsystem": "cec_hardware",
"Severity": "unrecoverable",
"SRC":
{
"ReasonCode": "0x3000",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "Failure occured during boot process",
"Message": "Failure occured during boot process",
"Notes": [
"Debug traces will be captured in AdditionalData section"
]
}
},
{
"Name": "org.open_power.Attn.Error.Terminate",
"Subsystem": "other_na",
"Severity": "critical_system_term",
"SRC":
{
"ReasonCode": "0xD138",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "Status shows TI special attention active",
"Message": "TI special attention detected",
"Notes": [
"This entry is for any TI special attention event ",
"reported by the attention handler component"
]
}
},
{
"Name": "org.open_power.Attn.Error.Fail",
"Subsystem": "bmc_firmware",
"Severity": "unrecoverable_loss_of_function",
"SRC":
{
"ReasonCode": "0xD13E",
"Words6To9":
{
"6":
{
"Description": "Error code from attention handler",
"AdditionalDataPropSource": "ERROR_CODE"
}
}
},
"Documentation":
{
"Description": "The attention handler encountered an error",
"MessageArgSources" : ["SRCWord6"],
"Message": "Attention handler error %1",
"Notes": [
"Attention handler will provide error code"
]
}
},
{
"Name": "org.open_power.Attn.Error.Vital",
"Subsystem": "processor_chip",
"Severity": "critical",
"SRC":
{
"ReasonCode": "0xD16D",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "Status shows SBE vital attention active",
"Message": "SBE vital attention detected",
"Notes": [
"This entry is for any SBE vital attention event ",
"reported by the attention handler component"
]
}
},
{
"Name": "org.open_power.HwDiags.Error.Checkstop",
"Subsystem": "cec_hardware",
"ActionFlags": [ "service_action", "report", "call_home" ],
"SRC":
{
"ReasonCode": "0xE510",
"SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ],
"Words6To9":
{
"6":
{
"Description": "[0:15] chip model, [16:23] reserved, [24:31] chip EC level",
"AdditionalDataPropSource": "SRC6"
},
"7":
{
"Description": "[0:15] chip position, [16:23] unused, [24:31] signature attn type",
"AdditionalDataPropSource": "SRC7"
},
"8":
{
"Description": "[0:15] signature ID, [16:23] signature instance, [24:31] signature bit position",
"AdditionalDataPropSource": "SRC8"
}
}
},
"Documentation":
{
"Description": "A system checkstop attention has occurred",
"MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ],
"Message": "hw-diags signature: %1 %2 %3"
}
},
{
"Name": "org.open_power.HwDiags.Error.Predictive",
"Subsystem": "cec_hardware",
"ActionFlags": [ "service_action", "report", "call_home" ],
"SRC":
{
"ReasonCode": "0xE511",
"SymptomIDFields": [ "SRCWord6", "SRCWord7", "SRCWord8" ],
"Words6To9":
{
"6":
{
"Description": "[0:15] chip model, [16:23] reserved, [24:31] chip EC level",
"AdditionalDataPropSource": "SRC6"
},
"7":
{
"Description": "[0:15] chip position, [16:23] unused, [24:31] signature attn type",
"AdditionalDataPropSource": "SRC7"
},
"8":
{
"Description": "[0:15] signature ID, [16:23] signature instance, [24:31] signature bit position",
"AdditionalDataPropSource": "SRC8"
}
}
},
"Documentation":
{
"Description": "A hardware attention requiring service has occurred",
"MessageArgSources" : [ "SRCWord6", "SRCWord7", "SRCWord8" ],
"Message": "hw-diags signature: %1 %2 %3"
}
},
{
"Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault",
"Subsystem": "power_supply",
"Severity": "unrecoverable_redundancy_loss",
"ActionFlags": ["service_action", "report"],
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x15F0",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pwrsply" }
]
}
],
"Documentation": {
"Description": "Power Supply input power fault",
"Message": "A power supply has indicated an input or under voltage condition.",
"Notes": [
"Check the power supply cabling and/or input power ",
"source. The PWRSPLY procedure is used rather than ",
"calling out a location code, as typically these faults ",
"are related to the supplied power, the cable, or the ",
"cable connectors. If the input fault resolves down to an ",
"issue with the power supply itself, the power supply ",
"indicating this input fault should be called out. Add the ",
"CALLOUT_INVENTORY_PATH to the additional data, and set the",
"CALLOUT_PRIORITY to something other than high."
]
}
},
{
"Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault",
"Subsystem": "power_supply",
"Severity": "unrecoverable_redundancy_loss",
"ActionFlags": ["service_action", "report", "call_home"],
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x15F1",
"Words6To9": {}
},
"Documentation": {
"Description": "Power Supply power fault",
"Message": "The power supply detected a fault condition, see AdditionalData for further details.",
"Notes": [
"The power supply reporting the fault should be called ",
"out using the CALLOUT_INVENTORY_PATH keyword. Include ",
"specific fault, STATUS_* details, and code level in the ",
"AdditionalData section."
]
}
},
{
"Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault",
"Subsystem": "power_supply",
"Severity": "unrecoverable_redundancy_loss",
"ActionFlags": ["service_action", "report", "call_home"],
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x15F2",
"Words6To9": {}
},
"Documentation": {
"Description": "Power Supply non-power fault",
"Message": "A communication failure occurred talking to the power supply",
"Notes": [
"Communication problems with the power supply could be ",
"the power supply, or any hardware between it and the ",
"BMC. Reporting the error should be passing in a call ",
"out using CALLOUT_DEVICE_PATH."
]
}
},
{
"Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing",
"Subsystem": "power_supply",
"Severity": "unrecoverable",
"ActionFlags": ["service_action", "report", "call_home"],
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x15F6",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{
"Priority": "high",
"SymbolicFRUTrusted": "pwrsply",
"UseInventoryLocCode": true
}
]
}
],
"Documentation": {
"Description": "Power Supply is missing",
"Message": "A power supply that should be present is missing",
"Notes": [
"The CalloutList should use the PWRSPLY symbolic FRU ",
"with the trusted location code property. The ",
"location code in this callout is obtained from ",
"the passed in CALLOUT_INVENTORY_PATH value."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.Shutdown",
"Subsystem": "power_sequencer",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x2600",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
],
"Documentation": {
"Description": "A power off was issued because a power fault was detected",
"Message": "A power off was issued because a power fault was detected",
"Notes": [
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.PowerSequencerPGOODFault",
"Subsystem": "power_sequencer",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x2610",
"Words6To9": {}
},
"CalloutsUsingAD": {
"ADName": "INPUT_NAME", "CalloutsWithTheirADValues": [
{
"ADValue": "PCIE_SLOT0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C0" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C1" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT2", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C2" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT3", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C3" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT4", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C4" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT7", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C7" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT8", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C8" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT9", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C9" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT10", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C10" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PCIE_SLOT11", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C11" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_12A", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12B", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12C", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12D", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12L", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12M", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12N", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12P", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12PCIE", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12Q", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_12R", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "PGOOD_VDN_DCM0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C14" },
{ "Priority": "medium", "LocCode": "P0-C15" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VDN_DCM1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C23" },
{ "Priority": "medium", "LocCode": "P0-C24" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VCS_DCM0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C14" },
{ "Priority": "medium", "LocCode": "P0-C15" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VCS_DCM1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C23" },
{ "Priority": "medium", "LocCode": "P0-C24" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VIO_DCM0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C14" },
{ "Priority": "medium", "LocCode": "P0-C15" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VIO_DCM1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C23" },
{ "Priority": "medium", "LocCode": "P0-C24" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VPCIE_DCM0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C14" },
{ "Priority": "medium", "LocCode": "P0-C15" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "PGOOD_VPCIE_DCM1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C23" },
{ "Priority": "medium", "LocCode": "P0-C24" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
}
]
},
"Documentation": {
"Description": "The power sequencer chip detected a PGOOD fault",
"Message": "The power sequencer chip detected a PGOOD fault",
"Notes": [
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault",
"Subsystem": "power_sequencer",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x2620",
"Words6To9": {}
},
"CalloutsUsingAD": {
"ADName": "RAIL_NAME", "CalloutsWithTheirADValues": [
{
"ADValue": "12.0V", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "5.0V_USB", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "usb_pgood" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "5.0V_DASD", "Callouts": [
{
"CalloutList": [
{ "Priority": "medium", "LocCode": "P1" },
{ "Priority": "medium", "LocCode": "P2" },
{ "Priority": "medium", "LocCode": "P3" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "3.3VA", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "3.3VB", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "1.5V", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "1.1V", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "VDDA_DCM0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C14" },
{ "Priority": "medium", "LocCode": "P0-C15" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "VDDB_DCM0", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C14" },
{ "Priority": "medium", "LocCode": "P0-C15" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "VDDA_DCM1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C23" },
{ "Priority": "medium", "LocCode": "P0-C24" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "VDDB_DCM1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0-C23" },
{ "Priority": "medium", "LocCode": "P0-C24" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "12.0VCS", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "3.3VCS", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "1.1V_Current", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "5.0V_USB_Current", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "usb_pgood" },
{ "Priority": "medium", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "5.0V_DASD_Current", "Callouts": [
{
"CalloutList": [
{ "Priority": "medium", "LocCode": "P1" },
{ "Priority": "medium", "LocCode": "P2" },
{ "Priority": "medium", "LocCode": "P3" },
{ "Priority": "low", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "12.0VN", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "12.0VP", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "12.0VQ", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "12.0VR", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "SymbolicFRU": "pgood_part" }
]
}
]
},
{
"ADValue": "ThermalDiode1", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "ThermalDiode2", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "ThermalDiode3", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
},
{
"ADValue": "ThermalDiode4", "Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
]
}
]
},
"Documentation": {
"Description": "The power sequencer chip detected a voltage fault",
"Message": "The power sequencer chip detected a voltage fault",
"Notes": [
]
}
},
{
"Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x2900",
"Words6To9": {}
},
"Documentation": {
"Description": "A write verification error occurred on a device",
"Message": "A write verification error occurred on a device",
"Notes": [
"This error occurs when a device register is written, ",
"read back, and the two values do not match. This is ",
"also called a read-back error. The device should be ",
"identified using the CALLOUT_DEVICE_PATH or ",
"CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ",
"AdditionalData property of the event log. This will ",
"cause the device and the hardware in the communication ",
"path to be called out."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xA013",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "Procedure": "bmc_code" }
]
}
],
"Documentation": {
"Description": "A regulators configuration file error occurred",
"Message": "A regulators configuration file error occurred",
"Notes": [
"The regulators configuration file could not be found, ",
"could not be read, or had invalid contents."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.PowerSequencerFault",
"Subsystem": "power_sequencer",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xD000",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
],
"Documentation": {
"Description": "The power sequencer chip detected a fault",
"Message": "The power sequencer chip detected a fault",
"Notes": [
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.PowerOnFailure",
"Subsystem": "power_sequencer",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xD002",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "LocCode": "P0" }
]
}
],
"Documentation": {
"Description": "System power failed to turn on",
"Message": "System power failed to turn on",
"Notes": [
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.Internal",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE000",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "Procedure": "bmc_code" }
]
}
],
"Documentation": {
"Description": "An internal firmware error occurred",
"Message": "An internal firmware error occurred",
"Notes": [
"The error details must be provided in the AdditionalData ",
"property of the event log."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.I2C",
"Subsystem": "cec_i2c",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE100",
"Words6To9": {}
},
"Documentation": {
"Description": "An I2C error occurred communicating with a device",
"Message": "An I2C error occurred communicating with a device",
"Notes": [
"The device should be identified using the ",
"CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ",
"keywords in the AdditionalData property of the event ",
"log. This will cause the device and the hardware in the ",
"communication path to be called out."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.PMBus",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE200",
"Words6To9": {}
},
"Documentation": {
"Description": "A PMBus error occurred on a device",
"Message": "A PMBus error occurred on a device",
"Notes": [
"This error occurs when the I2C communication was ",
"successful, but the PMBus value read is invalid or ",
"unsupported. CALLOUT_INVENTORY_PATH should be specified ",
"in the AdditionalData property of the event log so that ",
"the device is called out but not the communication path."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.DBus",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE300",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "Procedure": "bmc_code" }
]
}
],
"Documentation": {
"Description": "A firmware inter-process communication (D-Bus) error occurred",
"Message": "A firmware inter-process communication (D-Bus) error occurred"
}
},
{
"Name": "xyz.openbmc_project.Fan.Error.Fault",
"Subsystem": "power_fans",
"ComponentID": "0x2800",
"SRC": {
"Type": "11",
"ReasonCode": "0x76F0",
"Words6To9": {}
},
"Documentation": {
"Description": "Fan rotor fault",
"Message": "Fan rotor fault",
"Notes": [
"This error occurs when a fan rotor has been faulted for a ",
"certain amount of time. The callout is the fan which is ",
"passed in with CALLOUT_INVENTORY_PATH. The severity is ",
"passed in during creation and will be either informational ",
"or unrecoverable. The action flags use the defaults and ",
"vary based on the severity."
]
}
},
{
"Name": "xyz.openbmc_project.Fan.Error.Missing",
"Subsystem": "power_fans",
"ComponentID": "0x2800",
"Severity": "unrecoverable_redundancy_loss",
"ActionFlags": ["service_action", "report", "call_home"],
"SRC": {
"Type": "11",
"ReasonCode": "0x76F1",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{
"Priority": "high",
"SymbolicFRUTrusted": "air_mover",
"UseInventoryLocCode": true
},
{
"Priority": "low",
"LocCode": "P0"
}
]
}
],
"Documentation": {
"Description": "A fan is missing",
"Message": "A fan is missing",
"Notes": [
"This error occurs when a fan has been missing for a ",
"certain amount of time. The first callout is the ",
"symbolic FRU AIR_MOVR that has the trusted fan location ",
"code, which it gets using the passed in ",
"CALLOUT_INVENTORY_PATH. The second callout is the FRU ",
"where the controller is."
]
}
},
{
"Name": "com.ibm.VPD.Error.InvalidEepromPath",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",
"SRC": {
"ReasonCode": "0x4000",
"Words6To9":
{
"6":
{
"Description": "Errno of the failure.",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation": {
"Description": "A path access error ocurred",
"Message": "An EEPROM path access error occurred.",
"Notes": [
"This error occurs when parser is unable to access",
"EEPROM path. Errno and device path are captured as",
"additional data."
]
}
},
{
"Name": "com.ibm.VPD.Error.InvalidVPD",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",
"SRC": {
"ReasonCode": "0x4001",
"Words6To9":
{
}
},
"Documentation": {
"Description": "Invalid VPD data.",
"Message": "A VPD data exception occurred.",
"Notes": [
"This error occurs when VPD data is found to be",
"invalid. This can be when VPD file is missing out",
"mandatory records.Inventory path is captured in",
"additional data."
]
}
},
{
"Name": "com.ibm.VPD.Error.EccCheckFailed",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",
"SRC": {
"ReasonCode": "0x4002",
"Words6To9":
{
}
},
"Documentation": {
"Description": "Invalid VPD ecc data.",
"Message": "A VPD ecc exception occurred.",
"Notes": [
"This error occurs when VPD ecc check fails for the FRU.",
"Inventory path for the failed FRU is captured in additonal",
"data."
]
}
},
{
"Name": "com.ibm.VPD.Error.InvalidJson",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",
"SRC": {
"ReasonCode": "0x4003",
"Words6To9":
{
}
},
"Documentation": {
"Description": "Invalid Json",
"Message": "A Json failure occurred.",
"Notes": [
"This error occurs when parser fails to access",
"Json file or there is any issue with Json data.",
"Failed Json path and cause of failure is captured",
"in additional data."
]
}
},
{
"Name": "com.ibm.VPD.Error.BlankSystemVPD",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",
"SRC": {
"ReasonCode": "0x4004",
"Words6To9":
{
}
},
"Documentation": {
"Description": "System VPD restore failed",
"Message": "A system VPD restoration error occurred.",
"Notes": [
"This error occurs when restoring of system VPD fails.",
"The FRU path and reason for failure is captured in",
"additional data."
]
}
},
{
"Name": "com.ibm.VPD.Error.DbusFailure",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",
"SRC": {
"ReasonCode": "0x4005",
"Words6To9":
{
}
},
"Documentation": {
"Description": "Dbus exception",
"Message": "A Dbus internal error occurred.",
"Notes": [
"This error occurs when Dbus operation fails.",
"Exceptions details are captured in additonal",
"data."
]
}
}
]
}