blob: b4bf308a612260816a748a8fc30789e1d696b1b3 [file] [log] [blame]
{
"PELs":
[
{
"Name": "xyz.openbmc_project.Common.Error.Timeout",
"Subsystem": "bmc_firmware",
"SRC":
{
"ReasonCode": "0x1001",
"Words6To9":
{
"6":
{
"Description": "Timeout in ms",
"AdditionalDataPropSource": "TIMEOUT_IN_MSEC"
}
}
},
"Documentation":
{
"Description": "This is a generic timeout error",
"Message": "An operation timed out",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.InternalFailure",
"Subsystem": "bmc_firmware",
"SRC":
{
"ReasonCode": "0x1002",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "BMC code had a generic internal failure",
"Message": "An application had an internal failure",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.InvalidArgument",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1003",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "BMC code was given an invalid argument",
"Message": "Code was given an invalid argument",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.InsufficientPermission",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1004",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "An operation failed due to insufficient permission",
"Message": "An operation failed due to unsufficient permission",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.NotAllowed",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1005",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "An operation failed because it isn't allowed",
"Message": "An operation failed becuase it isn't allowed",
"Notes": [
"The journal should contain more information"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Error.NoCACertificate",
"Subsystem": "user_error",
"SRC":
{
"ReasonCode": "0x1006",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "The server's CA certificate has not been provided",
"Message": "The server's CA certificate has not been provided"
}
},
{
"Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x1007",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Sensor device read failure",
"Message": "There was a failure when reading a sensor device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH."
]
}
},
{
"Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x1008",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Device read failure",
"Message": "There was a failure when reading a hardware device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH."
]
}
},
{
"Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x1009",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Device write failure",
"Message": "There was a failure when writing to a hardware device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH"
]
}
},
{
"Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure",
"Subsystem": "cec_chip_iface",
"SRC":
{
"ReasonCode": "0x100A",
"Words6To9":
{
"6":
{
"Description": "errno of the failure",
"AdditionalDataPropSource": "CALLOUT_ERRNO"
}
}
},
"Documentation":
{
"Description": "Device write failure",
"Message": "There was a failure when writing to a hardware device",
"Notes": [
"The severity is set by the creator.",
"The action flags are set automatically by the code.",
"Callouts added based on CALLOUT_DEVICE_PATH"
]
}
},
{
"Name": "org.open_power.Logging.Error.SentBadPELToHost",
"Subsystem": "bmc_firmware",
"Severity": "non_error",
"SRC":
{
"ReasonCode": "0x2001",
"Words6To9":
{
"6":
{
"Description": "The bad PEL ID",
"AdditionalDataPropSource": "BAD_ID"
}
}
},
"Documentation":
{
"Description": "The BMC sent the host a malformed PEL",
"Message": "The BMC sent the host a malformed PEL",
"Notes": [
"The host firmware rejected that PEL."
]
}
},
{
"Name": "org.open_power.Logging.Error.BadHostPEL",
"Subsystem": "platform_firmware",
"Severity": "unrecoverable",
"SRC":
{
"ReasonCode": "0x2002",
"Words6To9":
{
"6":
{
"Description": "The PLID of the invalid PEL",
"AdditionalDataPropSource": "PLID"
},
"7":
{
"Description": "The corresponding OpenBMC event log ID",
"AdditionalDataPropSource": "OBMC_LOG_ID"
},
"8":
{
"Description": "The size of the invalid PEL",
"AdditionalDataPropSource": "PEL_SIZE"
}
}
},
"Documentation":
{
"Description": "The host sent the BMC an invalid PEL",
"Message": "The host sent the BMC an invalid PEL",
"Notes": [
]
}
},
{
"Name": "org.open_power.Logging.Error.TestError1",
"Subsystem": "platform_firmware",
"Severity": "unrecoverable",
"SRC":
{
"ReasonCode": "0x2003",
"Words6To9":
{
}
},
"Callouts": [
{
"CalloutList": [
{"Priority": "high", "Procedure": "bmc_code"},
{"Priority": "medium", "SymbolicFRU": "service_docs"}
]
}
],
"Documentation":
{
"Description": "An error for testing",
"Message": "This is a test error"
}
},
{
"Name": "org.open_power.PHAL.Error.Boot",
"Subsystem": "cec_hardware",
"Severity": "unrecoverable",
"SRC":
{
"ReasonCode": "0x3000",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "Failure occured during boot process",
"Message": "Failure occured during boot process",
"Notes": [
"Debug traces will be captured in AdditionalData section"
]
}
},
{
"Name": "org.open_power.Attn.Error.Terminate",
"Subsystem": "other_na",
"Severity": "critical_system_term",
"SRC":
{
"ReasonCode": "0xD138",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "Status shows TI special attention active",
"Message": "TI special attention detected",
"Notes": [
"This entry is for any TI special attention event ",
"reported by the attention handler component"
]
}
},
{
"Name": "org.open_power.Attn.Error.Fail",
"Subsystem": "bmc_firmware",
"Severity": "unrecoverable_loss_of_function",
"SRC":
{
"ReasonCode": "0xD13E",
"Words6To9":
{
"6":
{
"Description": "Error code from attention handler",
"AdditionalDataPropSource": "ERROR_CODE"
}
}
},
"Documentation":
{
"Description": "The attention handler encountered an error",
"MessageArgSources" : ["SRCWord6"],
"Message": "Attention handler error %1",
"Notes": [
"Attention handler will provide error code"
]
}
},
{
"Name": "org.open_power.Attn.Error.Vital",
"Subsystem": "processor_chip",
"Severity": "critical",
"SRC":
{
"ReasonCode": "0xD16D",
"Words6To9":
{
}
},
"Documentation":
{
"Description": "Status shows SBE vital attention active",
"Message": "SBE vital attention detected",
"Notes": [
"This entry is for any SBE vital attention event ",
"reported by the attention handler component"
]
}
},
{
"Name": "org.open_power.HwDiags.Error.Checkstop",
"Subsystem": "cec_hardware",
"Severity": "critical",
"SRC":
{
"ReasonCode": "0xE504",
"Words6To9":
{
"6":
{
"Description": "Chip ID",
"AdditionalDataPropSource": "CHIP_ID"
},
"8":
{
"Description": "Error Signature",
"AdditionalDataPropSource": "SIGNATURE"
}
}
},
"Documentation":
{
"Description": "A checkstop condition has been detected",
"MessageArgSources" : ["SRCWord6", "SRCWord8"],
"Message": "Checkstop: Chip %1, Signature %2",
"Notes": [
"This entry is for any checkstop event reported by ",
"the hardware diagnostics component."
]
}
},
{
"Name": "org.open_power.HwDiags.Error.Fail",
"Subsystem": "bmc_firmware",
"Severity": "diagnostic_error",
"SRC":
{
"ReasonCode": "0xE580",
"Words6To9":
{
"6":
{
"Description": "Error code from hardware diagnostics",
"AdditionalDataPropSource": "ERROR_CODE"
}
}
},
"Documentation":
{
"Description": "Hardware diagnostics encountered an error",
"MessageArgSources" : ["SRCWord6"],
"Message": "Hardware diagnostics error %1",
"Notes": [
"Hardware diagnostics will provide error code"
]
}
},
{
"Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0x2900",
"Words6To9": {}
},
"Documentation": {
"Description": "A write verification error occurred on a device",
"Message": "A write verification error occurred on a device",
"Notes": [
"This error occurs when a device register is written, ",
"read back, and the two values do not match. This is ",
"also called a read-back error. The device should be ",
"identified using the CALLOUT_DEVICE_PATH or ",
"CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ",
"AdditionalData property of the event log. This will ",
"cause the device and the hardware in the communication ",
"path to be called out."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xA013",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "Procedure": "bmc_code" }
]
}
],
"Documentation": {
"Description": "A regulators configuration file error occurred",
"Message": "A regulators configuration file error occurred",
"Notes": [
"The regulators configuration file could not be found, ",
"could not be read, or had invalid contents."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.Internal",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE000",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "Procedure": "bmc_code" }
]
}
],
"Documentation": {
"Description": "An internal firmware error occurred",
"Message": "An internal firmware error occurred",
"Notes": [
"The error details must be provided in the AdditionalData ",
"property of the event log."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.I2C",
"Subsystem": "cec_i2c",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE100",
"Words6To9": {}
},
"Documentation": {
"Description": "An I2C error occurred communicating with a device",
"Message": "An I2C error occurred communicating with a device",
"Notes": [
"The device should be identified using the ",
"CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ",
"keywords in the AdditionalData property of the event ",
"log. This will cause the device and the hardware in the ",
"communication path to be called out."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.PMBus",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE200",
"Words6To9": {}
},
"Documentation": {
"Description": "A PMBus error occurred on a device",
"Message": "A PMBus error occurred on a device",
"Notes": [
"This error occurs when the I2C communication was ",
"successful, but the PMBus value read is invalid or ",
"unsupported. CALLOUT_INVENTORY_PATH should be specified ",
"in the AdditionalData property of the event log so that ",
"the device is called out but not the communication path."
]
}
},
{
"Name": "xyz.openbmc_project.Power.Error.DBus",
"Subsystem": "power",
"ComponentID": "0x2700",
"SRC": {
"Type": "11",
"ReasonCode": "0xE300",
"Words6To9": {}
},
"Callouts": [
{
"CalloutList": [
{ "Priority": "high", "Procedure": "bmc_code" }
]
}
],
"Documentation": {
"Description": "A firmware inter-process communication (D-Bus) error occurred",
"Message": "A firmware inter-process communication (D-Bus) error occurred"
}
}
]
}