Matt Spinler | 44792fd | 2019-09-26 15:58:58 -0500 | [diff] [blame] | 1 | { |
| 2 | "PELs": |
| 3 | [ |
Matt Spinler | 3fd08d6 | 2019-10-22 14:25:33 -0500 | [diff] [blame] | 4 | { |
| 5 | "Name": "xyz.openbmc_project.Common.Error.Timeout", |
| 6 | "Subsystem": "bmc_firmware", |
Matt Spinler | 44792fd | 2019-09-26 15:58:58 -0500 | [diff] [blame] | 7 | |
Matt Spinler | 3fd08d6 | 2019-10-22 14:25:33 -0500 | [diff] [blame] | 8 | "SRC": |
| 9 | { |
| 10 | "ReasonCode": "0x1001", |
| 11 | "Words6To9": |
| 12 | { |
| 13 | "6": |
| 14 | { |
| 15 | "Description": "Timeout in ms", |
| 16 | "AdditionalDataPropSource": "TIMEOUT_IN_MSEC" |
| 17 | } |
| 18 | } |
| 19 | }, |
| 20 | |
| 21 | "Documentation": |
| 22 | { |
| 23 | "Description": "This is a generic timeout error", |
| 24 | "Message": "An operation timed out", |
| 25 | "Notes": [ |
| 26 | "The journal should contain more information" |
| 27 | ] |
| 28 | } |
| 29 | }, |
| 30 | |
| 31 | { |
| 32 | "Name": "xyz.openbmc_project.Common.Error.InternalFailure", |
| 33 | "Subsystem": "bmc_firmware", |
| 34 | |
| 35 | "SRC": |
| 36 | { |
| 37 | "ReasonCode": "0x1002", |
| 38 | "Words6To9": |
| 39 | { |
| 40 | } |
| 41 | }, |
| 42 | |
| 43 | "Documentation": |
| 44 | { |
| 45 | "Description": "BMC code had a generic internal failure", |
| 46 | "Message": "An application had an internal failure", |
| 47 | "Notes": [ |
| 48 | "The journal should contain more information" |
| 49 | ] |
| 50 | } |
| 51 | }, |
| 52 | |
| 53 | { |
| 54 | "Name": "xyz.openbmc_project.Common.Error.InvalidArgument", |
| 55 | "Subsystem": "user_error", |
| 56 | |
| 57 | "SRC": |
| 58 | { |
| 59 | "ReasonCode": "0x1003", |
| 60 | "Words6To9": |
| 61 | { |
| 62 | } |
| 63 | }, |
| 64 | |
| 65 | "Documentation": |
| 66 | { |
| 67 | "Description": "BMC code was given an invalid argument", |
| 68 | "Message": "Code was given an invalid argument", |
| 69 | "Notes": [ |
| 70 | "The journal should contain more information" |
| 71 | ] |
| 72 | } |
| 73 | }, |
| 74 | { |
| 75 | "Name": "xyz.openbmc_project.Common.Error.InsufficientPermission", |
| 76 | "Subsystem": "user_error", |
| 77 | |
| 78 | "SRC": |
| 79 | { |
| 80 | "ReasonCode": "0x1004", |
| 81 | "Words6To9": |
| 82 | { |
| 83 | } |
| 84 | }, |
| 85 | |
| 86 | "Documentation": |
| 87 | { |
| 88 | "Description": "An operation failed due to insufficient permission", |
| 89 | "Message": "An operation failed due to unsufficient permission", |
| 90 | "Notes": [ |
| 91 | "The journal should contain more information" |
| 92 | ] |
| 93 | } |
| 94 | }, |
| 95 | |
| 96 | { |
| 97 | "Name": "xyz.openbmc_project.Common.Error.NotAllowed", |
| 98 | "Subsystem": "user_error", |
| 99 | |
| 100 | "SRC": |
| 101 | { |
| 102 | "ReasonCode": "0x1005", |
| 103 | "Words6To9": |
| 104 | { |
| 105 | } |
| 106 | }, |
| 107 | |
| 108 | "Documentation": |
| 109 | { |
| 110 | "Description": "An operation failed because it isn't allowed", |
Matt Spinler | 2695876 | 2020-08-27 13:21:23 -0500 | [diff] [blame] | 111 | "Message": "An operation failed because it isn't allowed", |
Matt Spinler | 3fd08d6 | 2019-10-22 14:25:33 -0500 | [diff] [blame] | 112 | "Notes": [ |
| 113 | "The journal should contain more information" |
| 114 | ] |
| 115 | } |
| 116 | }, |
| 117 | |
| 118 | { |
| 119 | "Name": "xyz.openbmc_project.Common.Error.NoCACertificate", |
| 120 | "Subsystem": "user_error", |
| 121 | |
| 122 | "SRC": |
| 123 | { |
| 124 | "ReasonCode": "0x1006", |
| 125 | "Words6To9": |
| 126 | { |
| 127 | } |
| 128 | }, |
| 129 | |
| 130 | "Documentation": |
| 131 | { |
| 132 | "Description": "The server's CA certificate has not been provided", |
| 133 | "Message": "The server's CA certificate has not been provided" |
| 134 | } |
Matt Spinler | 05c2c6c | 2019-12-18 14:02:09 -0600 | [diff] [blame] | 135 | }, |
| 136 | |
| 137 | { |
Matt Spinler | af036b1 | 2020-06-25 10:53:52 -0500 | [diff] [blame] | 138 | "Name": "xyz.openbmc_project.Sensor.Device.Error.ReadFailure", |
| 139 | "Subsystem": "cec_chip_iface", |
| 140 | |
| 141 | "SRC": |
| 142 | { |
| 143 | "ReasonCode": "0x1007", |
| 144 | "Words6To9": |
| 145 | { |
| 146 | "6": |
| 147 | { |
| 148 | "Description": "errno of the failure", |
| 149 | "AdditionalDataPropSource": "CALLOUT_ERRNO" |
| 150 | } |
| 151 | } |
| 152 | }, |
| 153 | |
| 154 | "Documentation": |
| 155 | { |
| 156 | "Description": "Sensor device read failure", |
| 157 | "Message": "There was a failure when reading a sensor device", |
| 158 | "Notes": [ |
| 159 | "The severity is set by the creator.", |
| 160 | "The action flags are set automatically by the code.", |
| 161 | "Callouts added based on CALLOUT_DEVICE_PATH." |
| 162 | ] |
| 163 | } |
| 164 | }, |
| 165 | |
| 166 | { |
| 167 | "Name": "xyz.openbmc_project.Common.Device.Error.ReadFailure", |
| 168 | "Subsystem": "cec_chip_iface", |
| 169 | |
| 170 | "SRC": |
| 171 | { |
| 172 | "ReasonCode": "0x1008", |
| 173 | "Words6To9": |
| 174 | { |
| 175 | "6": |
| 176 | { |
| 177 | "Description": "errno of the failure", |
| 178 | "AdditionalDataPropSource": "CALLOUT_ERRNO" |
| 179 | } |
| 180 | } |
| 181 | }, |
| 182 | |
| 183 | "Documentation": |
| 184 | { |
| 185 | "Description": "Device read failure", |
| 186 | "Message": "There was a failure when reading a hardware device", |
| 187 | "Notes": [ |
| 188 | "The severity is set by the creator.", |
| 189 | "The action flags are set automatically by the code.", |
| 190 | "Callouts added based on CALLOUT_DEVICE_PATH." |
| 191 | ] |
| 192 | } |
| 193 | }, |
| 194 | |
| 195 | { |
| 196 | "Name": "xyz.openbmc_project.Control.Device.Error.WriteFailure", |
| 197 | "Subsystem": "cec_chip_iface", |
| 198 | |
| 199 | "SRC": |
| 200 | { |
| 201 | "ReasonCode": "0x1009", |
| 202 | "Words6To9": |
| 203 | { |
| 204 | "6": |
| 205 | { |
| 206 | "Description": "errno of the failure", |
| 207 | "AdditionalDataPropSource": "CALLOUT_ERRNO" |
| 208 | } |
| 209 | } |
| 210 | }, |
| 211 | |
| 212 | "Documentation": |
| 213 | { |
| 214 | "Description": "Device write failure", |
| 215 | "Message": "There was a failure when writing to a hardware device", |
| 216 | "Notes": [ |
| 217 | "The severity is set by the creator.", |
| 218 | "The action flags are set automatically by the code.", |
| 219 | "Callouts added based on CALLOUT_DEVICE_PATH" |
| 220 | ] |
| 221 | } |
| 222 | }, |
| 223 | |
| 224 | { |
| 225 | "Name": "xyz.openbmc_project.Common.Device.Error.WriteFailure", |
| 226 | "Subsystem": "cec_chip_iface", |
| 227 | |
| 228 | "SRC": |
| 229 | { |
| 230 | "ReasonCode": "0x100A", |
| 231 | "Words6To9": |
| 232 | { |
| 233 | "6": |
| 234 | { |
| 235 | "Description": "errno of the failure", |
| 236 | "AdditionalDataPropSource": "CALLOUT_ERRNO" |
| 237 | } |
| 238 | } |
| 239 | }, |
| 240 | |
| 241 | "Documentation": |
| 242 | { |
| 243 | "Description": "Device write failure", |
| 244 | "Message": "There was a failure when writing to a hardware device", |
| 245 | "Notes": [ |
| 246 | "The severity is set by the creator.", |
| 247 | "The action flags are set automatically by the code.", |
| 248 | "Callouts added based on CALLOUT_DEVICE_PATH" |
| 249 | ] |
| 250 | } |
| 251 | }, |
| 252 | { |
Matt Spinler | 05c2c6c | 2019-12-18 14:02:09 -0600 | [diff] [blame] | 253 | "Name": "org.open_power.Logging.Error.SentBadPELToHost", |
| 254 | "Subsystem": "bmc_firmware", |
| 255 | "Severity": "non_error", |
| 256 | |
| 257 | "SRC": |
| 258 | { |
| 259 | "ReasonCode": "0x2001", |
| 260 | "Words6To9": |
| 261 | { |
| 262 | "6": |
| 263 | { |
| 264 | "Description": "The bad PEL ID", |
| 265 | "AdditionalDataPropSource": "BAD_ID" |
| 266 | } |
| 267 | } |
| 268 | }, |
| 269 | |
| 270 | "Documentation": |
| 271 | { |
| 272 | "Description": "The BMC sent the host a malformed PEL", |
| 273 | "Message": "The BMC sent the host a malformed PEL", |
| 274 | "Notes": [ |
| 275 | "The host firmware rejected that PEL." |
| 276 | ] |
| 277 | } |
Matt Spinler | e95fd01 | 2020-01-07 12:53:16 -0600 | [diff] [blame] | 278 | }, |
| 279 | |
| 280 | { |
| 281 | "Name": "org.open_power.Logging.Error.BadHostPEL", |
| 282 | "Subsystem": "platform_firmware", |
| 283 | "Severity": "unrecoverable", |
| 284 | |
| 285 | "SRC": |
| 286 | { |
| 287 | "ReasonCode": "0x2002", |
| 288 | "Words6To9": |
| 289 | { |
| 290 | "6": |
| 291 | { |
| 292 | "Description": "The PLID of the invalid PEL", |
| 293 | "AdditionalDataPropSource": "PLID" |
| 294 | }, |
| 295 | "7": |
| 296 | { |
| 297 | "Description": "The corresponding OpenBMC event log ID", |
| 298 | "AdditionalDataPropSource": "OBMC_LOG_ID" |
| 299 | }, |
| 300 | "8": |
| 301 | { |
| 302 | "Description": "The size of the invalid PEL", |
| 303 | "AdditionalDataPropSource": "PEL_SIZE" |
| 304 | } |
| 305 | } |
| 306 | }, |
| 307 | |
| 308 | "Documentation": |
| 309 | { |
| 310 | "Description": "The host sent the BMC an invalid PEL", |
| 311 | "Message": "The host sent the BMC an invalid PEL", |
| 312 | "Notes": [ |
| 313 | ] |
| 314 | } |
Marri Devender Rao | ead1be2 | 2020-03-28 05:50:59 -0500 | [diff] [blame] | 315 | }, |
| 316 | |
| 317 | { |
Matt Spinler | 3477ce9 | 2020-07-08 14:49:25 -0500 | [diff] [blame] | 318 | "Name": "org.open_power.Logging.Error.TestError1", |
| 319 | "Subsystem": "platform_firmware", |
| 320 | "Severity": "unrecoverable", |
| 321 | |
| 322 | "SRC": |
| 323 | { |
| 324 | "ReasonCode": "0x2003", |
| 325 | "Words6To9": |
| 326 | { |
| 327 | } |
| 328 | }, |
| 329 | |
| 330 | "Callouts": [ |
| 331 | { |
| 332 | "CalloutList": [ |
| 333 | {"Priority": "high", "Procedure": "bmc_code"}, |
| 334 | {"Priority": "medium", "SymbolicFRU": "service_docs"} |
| 335 | ] |
| 336 | } |
| 337 | ], |
| 338 | |
| 339 | "Documentation": |
| 340 | { |
| 341 | "Description": "An error for testing", |
| 342 | "Message": "This is a test error" |
| 343 | } |
| 344 | }, |
| 345 | |
| 346 | { |
Matt Spinler | 30ddc9f | 2020-07-16 15:39:59 -0500 | [diff] [blame] | 347 | "Name": "xyz.openbmc_project.Logging.Error.Default", |
| 348 | "Subsystem": "other_na", |
| 349 | |
| 350 | "SRC": |
| 351 | { |
| 352 | "ReasonCode": "0x2004", |
| 353 | "Words6To9": |
| 354 | { |
| 355 | } |
| 356 | }, |
| 357 | |
| 358 | "Documentation": |
| 359 | { |
| 360 | "Description": "This entry is used when no other matching entry is found", |
| 361 | "Message": "Unknown (Original event not in message registry)", |
| 362 | "Notes": [ |
| 363 | "This is used when the actual error name isn't found in ", |
| 364 | "the registry. The original error name will be stored ", |
| 365 | "in the UserData section that contains the AdditionalData ", |
| 366 | "properties using the key ERROR_NAME.", |
| 367 | "This error may contain callouts if the creator passed ", |
| 368 | "them in.", |
| 369 | "The severity is set by the creator.", |
| 370 | "If this error is seen, then a code change needs to be ", |
| 371 | "made to add the missing error entry to this registry." |
| 372 | ] |
| 373 | } |
| 374 | }, |
| 375 | |
| 376 | { |
Marri Devender Rao | ead1be2 | 2020-03-28 05:50:59 -0500 | [diff] [blame] | 377 | "Name": "org.open_power.PHAL.Error.Boot", |
| 378 | "Subsystem": "cec_hardware", |
| 379 | "Severity": "unrecoverable", |
| 380 | |
| 381 | "SRC": |
| 382 | { |
| 383 | "ReasonCode": "0x3000", |
| 384 | "Words6To9": |
| 385 | { |
| 386 | } |
| 387 | }, |
| 388 | |
| 389 | "Documentation": |
| 390 | { |
| 391 | "Description": "Failure occured during boot process", |
| 392 | "Message": "Failure occured during boot process", |
| 393 | "Notes": [ |
| 394 | "Debug traces will be captured in AdditionalData section" |
| 395 | ] |
| 396 | } |
Ben Tyner | 3483632 | 2020-04-15 17:01:48 -0500 | [diff] [blame] | 397 | }, |
| 398 | |
| 399 | { |
| 400 | "Name": "org.open_power.Attn.Error.Terminate", |
| 401 | "Subsystem": "other_na", |
| 402 | "Severity": "critical_system_term", |
| 403 | |
| 404 | "SRC": |
| 405 | { |
| 406 | "ReasonCode": "0xD138", |
| 407 | "Words6To9": |
| 408 | { |
| 409 | } |
| 410 | }, |
| 411 | |
| 412 | "Documentation": |
| 413 | { |
| 414 | "Description": "Status shows TI special attention active", |
| 415 | "Message": "TI special attention detected", |
| 416 | "Notes": [ |
| 417 | "This entry is for any TI special attention event ", |
| 418 | "reported by the attention handler component" |
| 419 | ] |
| 420 | } |
| 421 | }, |
| 422 | |
| 423 | { |
| 424 | "Name": "org.open_power.Attn.Error.Fail", |
| 425 | "Subsystem": "bmc_firmware", |
| 426 | "Severity": "unrecoverable_loss_of_function", |
| 427 | |
| 428 | "SRC": |
| 429 | { |
| 430 | "ReasonCode": "0xD13E", |
| 431 | "Words6To9": |
| 432 | { |
| 433 | "6": |
| 434 | { |
| 435 | "Description": "Error code from attention handler", |
| 436 | "AdditionalDataPropSource": "ERROR_CODE" |
| 437 | } |
| 438 | } |
| 439 | }, |
| 440 | "Documentation": |
| 441 | { |
| 442 | "Description": "The attention handler encountered an error", |
| 443 | "MessageArgSources" : ["SRCWord6"], |
| 444 | "Message": "Attention handler error %1", |
| 445 | "Notes": [ |
| 446 | "Attention handler will provide error code" |
| 447 | ] |
| 448 | } |
| 449 | }, |
| 450 | |
| 451 | { |
| 452 | "Name": "org.open_power.Attn.Error.Vital", |
| 453 | "Subsystem": "processor_chip", |
| 454 | "Severity": "critical", |
| 455 | |
| 456 | "SRC": |
| 457 | { |
| 458 | "ReasonCode": "0xD16D", |
| 459 | "Words6To9": |
| 460 | { |
| 461 | } |
| 462 | }, |
| 463 | |
| 464 | "Documentation": |
| 465 | { |
| 466 | "Description": "Status shows SBE vital attention active", |
| 467 | "Message": "SBE vital attention detected", |
| 468 | "Notes": [ |
| 469 | "This entry is for any SBE vital attention event ", |
| 470 | "reported by the attention handler component" |
| 471 | ] |
| 472 | } |
| 473 | }, |
| 474 | |
| 475 | { |
| 476 | "Name": "org.open_power.HwDiags.Error.Checkstop", |
| 477 | "Subsystem": "cec_hardware", |
| 478 | "Severity": "critical", |
| 479 | |
| 480 | "SRC": |
| 481 | { |
| 482 | "ReasonCode": "0xE504", |
| 483 | "Words6To9": |
| 484 | { |
| 485 | "6": |
| 486 | { |
| 487 | "Description": "Chip ID", |
| 488 | "AdditionalDataPropSource": "CHIP_ID" |
| 489 | }, |
| 490 | "8": |
| 491 | { |
| 492 | "Description": "Error Signature", |
| 493 | "AdditionalDataPropSource": "SIGNATURE" |
| 494 | } |
| 495 | } |
| 496 | }, |
| 497 | |
| 498 | "Documentation": |
| 499 | { |
| 500 | "Description": "A checkstop condition has been detected", |
| 501 | "MessageArgSources" : ["SRCWord6", "SRCWord8"], |
| 502 | "Message": "Checkstop: Chip %1, Signature %2", |
| 503 | "Notes": [ |
| 504 | "This entry is for any checkstop event reported by ", |
| 505 | "the hardware diagnostics component." |
| 506 | ] |
| 507 | } |
| 508 | }, |
| 509 | |
| 510 | { |
| 511 | "Name": "org.open_power.HwDiags.Error.Fail", |
| 512 | "Subsystem": "bmc_firmware", |
| 513 | "Severity": "diagnostic_error", |
| 514 | |
| 515 | "SRC": |
| 516 | { |
| 517 | "ReasonCode": "0xE580", |
| 518 | "Words6To9": |
| 519 | { |
| 520 | "6": |
| 521 | { |
| 522 | "Description": "Error code from hardware diagnostics", |
| 523 | "AdditionalDataPropSource": "ERROR_CODE" |
| 524 | } |
| 525 | } |
| 526 | }, |
| 527 | "Documentation": |
| 528 | { |
| 529 | "Description": "Hardware diagnostics encountered an error", |
| 530 | "MessageArgSources" : ["SRCWord6"], |
| 531 | "Message": "Hardware diagnostics error %1", |
| 532 | "Notes": [ |
| 533 | "Hardware diagnostics will provide error code" |
| 534 | ] |
| 535 | } |
Shawn McCarney | 01648f5 | 2020-06-25 11:42:02 -0500 | [diff] [blame] | 536 | }, |
| 537 | |
| 538 | { |
Brandon Wyman | 38caaf0 | 2020-09-01 16:07:42 -0500 | [diff] [blame] | 539 | "Name": "xyz.openbmc_project.Power.PowerSupply.Error.InputFault", |
| 540 | "Subsystem": "power_supply", |
| 541 | "Severity": "unrecoverable_redundancy_loss", |
| 542 | "ActionFlags": ["service_action", "report"], |
| 543 | "ComponentID": "0x2700", |
| 544 | |
| 545 | "SRC": { |
| 546 | "Type": "11", |
| 547 | "ReasonCode": "0x15F0", |
| 548 | "Words6To9": {} |
| 549 | }, |
| 550 | |
| 551 | "Callouts": [ |
| 552 | { |
| 553 | "CalloutList": [ |
| 554 | { "Priority": "high", "SymbolicFRU": "pwrsply" } |
| 555 | ] |
| 556 | } |
| 557 | ], |
| 558 | |
| 559 | "Documentation": { |
| 560 | "Description": "Power Supply input power fault", |
| 561 | "Message": "A power supply has indicated an input or under voltage condition.", |
| 562 | "Notes": [ |
| 563 | "Check the power supply cabling and/or input power ", |
| 564 | "source. The PWRSPLY procedure is used rather than ", |
| 565 | "calling out a location code, as typically these faults ", |
| 566 | "are related to the supplied power, the cable, or the ", |
| 567 | "cable connectors. If the input fault resolves down to an ", |
| 568 | "issue with the power supply itself, the power supply ", |
| 569 | "indicating this input fault should be called out. Add the ", |
| 570 | "CALLOUT_INVENTORY_PATH to the additional data, and set the", |
| 571 | "CALLOUT_PRIORITY to something other than high." |
| 572 | ] |
| 573 | } |
| 574 | }, |
| 575 | |
| 576 | { |
| 577 | "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Fault", |
| 578 | "Subsystem": "power_supply", |
| 579 | "Severity": "unrecoverable_redundancy_loss", |
| 580 | "ActionFlags": ["service_action", "report", "call_home"], |
| 581 | "ComponentID": "0x2700", |
| 582 | |
| 583 | "SRC": { |
| 584 | "Type": "11", |
| 585 | "ReasonCode": "0x15F1", |
| 586 | "Words6To9": {} |
| 587 | }, |
| 588 | |
| 589 | "Documentation": { |
| 590 | "Description": "Power Supply power fault", |
| 591 | "Message": "The power supply detected a fault condition, see AdditionalData for further details.", |
| 592 | "Notes": [ |
| 593 | "The power supply reporting the fault should be called ", |
| 594 | "out using the CALLOUT_INVENTORY_PATH keyword. Include ", |
| 595 | "specific fault, STATUS_* details, and code level in the ", |
| 596 | "AdditionalData section." |
| 597 | ] |
| 598 | } |
| 599 | }, |
| 600 | |
| 601 | { |
| 602 | "Name": "xyz.openbmc_project.Power.PowerSupply.Error.CommFault", |
| 603 | "Subsystem": "power_supply", |
| 604 | "Severity": "unrecoverable_redundancy_loss", |
| 605 | "ActionFlags": ["service_action", "report", "call_home"], |
| 606 | "ComponentID": "0x2700", |
| 607 | |
| 608 | "SRC": { |
| 609 | "Type": "11", |
| 610 | "ReasonCode": "0x15F2", |
| 611 | "Words6To9": {} |
| 612 | }, |
| 613 | |
| 614 | "Documentation": { |
| 615 | "Description": "Power Supply non-power fault", |
| 616 | "Message": "A communication failure occurred talking to the power supply", |
| 617 | "Notes": [ |
| 618 | "Communication problems with the power supply could be ", |
| 619 | "the power supply, or any hardware between it and the ", |
| 620 | "BMC. Reporting the error should be passing in a call ", |
| 621 | "out using CALLOUT_DEVICE_PATH." |
| 622 | ] |
| 623 | } |
| 624 | }, |
| 625 | |
| 626 | { |
| 627 | "Name": "xyz.openbmc_project.Power.PowerSupply.Error.Missing", |
| 628 | "Subsystem": "power_supply", |
| 629 | "Severity": "unrecoverable", |
| 630 | "ActionFlags": ["service_action", "report", "call_home"], |
| 631 | "ComponentID": "0x2700", |
| 632 | |
| 633 | "SRC": { |
| 634 | "Type": "11", |
| 635 | "ReasonCode": "0x15F6", |
| 636 | "Words6To9": {} |
| 637 | }, |
| 638 | |
| 639 | "Callouts": [ |
| 640 | { |
| 641 | "CalloutList": [ |
Matt Spinler | 8060019 | 2020-10-23 09:29:33 -0500 | [diff] [blame] | 642 | { |
| 643 | "Priority": "high", |
| 644 | "SymbolicFRUTrusted": "pwrsply", |
| 645 | "UseInventoryLocCode": true |
| 646 | } |
Brandon Wyman | 38caaf0 | 2020-09-01 16:07:42 -0500 | [diff] [blame] | 647 | ] |
| 648 | } |
| 649 | ], |
| 650 | |
| 651 | "Documentation": { |
| 652 | "Description": "Power Supply is missing", |
| 653 | "Message": "A power supply that should be present is missing", |
| 654 | "Notes": [ |
| 655 | "The CalloutList should use the PWRSPLY symbolic FRU ", |
Matt Spinler | 8060019 | 2020-10-23 09:29:33 -0500 | [diff] [blame] | 656 | "with the trusted location code property. The ", |
| 657 | "location code in this callout is obtained from ", |
| 658 | "the passed in CALLOUT_INVENTORY_PATH value." |
Brandon Wyman | 38caaf0 | 2020-09-01 16:07:42 -0500 | [diff] [blame] | 659 | ] |
| 660 | } |
| 661 | }, |
| 662 | |
| 663 | { |
Shawn McCarney | 01648f5 | 2020-06-25 11:42:02 -0500 | [diff] [blame] | 664 | "Name": "xyz.openbmc_project.Power.Regulators.Error.WriteVerification", |
| 665 | "Subsystem": "power", |
| 666 | "ComponentID": "0x2700", |
| 667 | |
| 668 | "SRC": { |
| 669 | "Type": "11", |
| 670 | "ReasonCode": "0x2900", |
| 671 | "Words6To9": {} |
| 672 | }, |
| 673 | |
| 674 | "Documentation": { |
| 675 | "Description": "A write verification error occurred on a device", |
| 676 | "Message": "A write verification error occurred on a device", |
| 677 | "Notes": [ |
| 678 | "This error occurs when a device register is written, ", |
| 679 | "read back, and the two values do not match. This is ", |
| 680 | "also called a read-back error. The device should be ", |
| 681 | "identified using the CALLOUT_DEVICE_PATH or ", |
| 682 | "CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR keywords in the ", |
| 683 | "AdditionalData property of the event log. This will ", |
| 684 | "cause the device and the hardware in the communication ", |
| 685 | "path to be called out." |
| 686 | ] |
| 687 | } |
| 688 | }, |
| 689 | |
| 690 | { |
| 691 | "Name": "xyz.openbmc_project.Power.Regulators.Error.ConfigFile", |
| 692 | "Subsystem": "power", |
| 693 | "ComponentID": "0x2700", |
| 694 | |
| 695 | "SRC": { |
| 696 | "Type": "11", |
| 697 | "ReasonCode": "0xA013", |
| 698 | "Words6To9": {} |
| 699 | }, |
| 700 | |
| 701 | "Callouts": [ |
| 702 | { |
| 703 | "CalloutList": [ |
| 704 | { "Priority": "high", "Procedure": "bmc_code" } |
| 705 | ] |
| 706 | } |
| 707 | ], |
| 708 | |
| 709 | "Documentation": { |
| 710 | "Description": "A regulators configuration file error occurred", |
| 711 | "Message": "A regulators configuration file error occurred", |
| 712 | "Notes": [ |
| 713 | "The regulators configuration file could not be found, ", |
| 714 | "could not be read, or had invalid contents." |
| 715 | ] |
| 716 | } |
| 717 | }, |
| 718 | |
| 719 | { |
| 720 | "Name": "xyz.openbmc_project.Power.Error.Internal", |
| 721 | "Subsystem": "power", |
| 722 | "ComponentID": "0x2700", |
| 723 | |
| 724 | "SRC": { |
| 725 | "Type": "11", |
| 726 | "ReasonCode": "0xE000", |
| 727 | "Words6To9": {} |
| 728 | }, |
| 729 | |
| 730 | "Callouts": [ |
| 731 | { |
| 732 | "CalloutList": [ |
| 733 | { "Priority": "high", "Procedure": "bmc_code" } |
| 734 | ] |
| 735 | } |
| 736 | ], |
| 737 | |
| 738 | "Documentation": { |
| 739 | "Description": "An internal firmware error occurred", |
| 740 | "Message": "An internal firmware error occurred", |
| 741 | "Notes": [ |
| 742 | "The error details must be provided in the AdditionalData ", |
| 743 | "property of the event log." |
| 744 | ] |
| 745 | } |
| 746 | }, |
| 747 | |
| 748 | { |
| 749 | "Name": "xyz.openbmc_project.Power.Error.I2C", |
| 750 | "Subsystem": "cec_i2c", |
| 751 | "ComponentID": "0x2700", |
| 752 | |
| 753 | "SRC": { |
| 754 | "Type": "11", |
| 755 | "ReasonCode": "0xE100", |
| 756 | "Words6To9": {} |
| 757 | }, |
| 758 | |
| 759 | "Documentation": { |
| 760 | "Description": "An I2C error occurred communicating with a device", |
| 761 | "Message": "An I2C error occurred communicating with a device", |
| 762 | "Notes": [ |
| 763 | "The device should be identified using the ", |
| 764 | "CALLOUT_DEVICE_PATH or CALLOUT_IIC_BUS/CALLOUT_IIC_ADDR ", |
| 765 | "keywords in the AdditionalData property of the event ", |
| 766 | "log. This will cause the device and the hardware in the ", |
| 767 | "communication path to be called out." |
| 768 | ] |
| 769 | } |
| 770 | }, |
| 771 | |
| 772 | { |
| 773 | "Name": "xyz.openbmc_project.Power.Error.PMBus", |
| 774 | "Subsystem": "power", |
| 775 | "ComponentID": "0x2700", |
| 776 | |
| 777 | "SRC": { |
| 778 | "Type": "11", |
| 779 | "ReasonCode": "0xE200", |
| 780 | "Words6To9": {} |
| 781 | }, |
| 782 | |
| 783 | "Documentation": { |
| 784 | "Description": "A PMBus error occurred on a device", |
| 785 | "Message": "A PMBus error occurred on a device", |
| 786 | "Notes": [ |
| 787 | "This error occurs when the I2C communication was ", |
| 788 | "successful, but the PMBus value read is invalid or ", |
| 789 | "unsupported. CALLOUT_INVENTORY_PATH should be specified ", |
| 790 | "in the AdditionalData property of the event log so that ", |
| 791 | "the device is called out but not the communication path." |
| 792 | ] |
| 793 | } |
| 794 | }, |
| 795 | |
| 796 | { |
| 797 | "Name": "xyz.openbmc_project.Power.Error.DBus", |
| 798 | "Subsystem": "power", |
| 799 | "ComponentID": "0x2700", |
| 800 | |
| 801 | "SRC": { |
| 802 | "Type": "11", |
| 803 | "ReasonCode": "0xE300", |
| 804 | "Words6To9": {} |
| 805 | }, |
| 806 | |
| 807 | "Callouts": [ |
| 808 | { |
| 809 | "CalloutList": [ |
| 810 | { "Priority": "high", "Procedure": "bmc_code" } |
| 811 | ] |
| 812 | } |
| 813 | ], |
| 814 | |
| 815 | "Documentation": { |
| 816 | "Description": "A firmware inter-process communication (D-Bus) error occurred", |
| 817 | "Message": "A firmware inter-process communication (D-Bus) error occurred" |
| 818 | } |
Matt Spinler | 60d1c39 | 2020-09-23 15:23:24 -0500 | [diff] [blame] | 819 | }, |
| 820 | |
| 821 | { |
Matt Spinler | 7c9c07e | 2020-10-22 10:16:37 -0500 | [diff] [blame] | 822 | "Name": "xyz.openbmc_project.Fan.Error.Fault", |
| 823 | "Subsystem": "power_fans", |
| 824 | "ComponentID": "0x2800", |
| 825 | |
| 826 | "SRC": { |
| 827 | "Type": "11", |
| 828 | "ReasonCode": "0x76F0", |
| 829 | "Words6To9": {} |
| 830 | }, |
| 831 | |
| 832 | "Documentation": { |
| 833 | "Description": "Fan rotor fault", |
| 834 | "Message": "Fan rotor fault", |
| 835 | "Notes": [ |
| 836 | "This error occurs when a fan rotor has been faulted for a ", |
| 837 | "certain amount of time. The callout is the fan which is ", |
| 838 | "passed in with CALLOUT_INVENTORY_PATH. The severity is ", |
| 839 | "passed in during creation and will be either informational ", |
| 840 | "or unrecoverable. The action flags use the defaults and ", |
| 841 | "vary based on the severity." |
| 842 | ] |
| 843 | } |
| 844 | }, |
| 845 | |
| 846 | { |
Matt Spinler | 60d1c39 | 2020-09-23 15:23:24 -0500 | [diff] [blame] | 847 | "Name": "xyz.openbmc_project.Fan.Error.Missing", |
| 848 | "Subsystem": "power_fans", |
| 849 | "ComponentID": "0x2800", |
| 850 | "Severity": "unrecoverable_redundancy_loss", |
| 851 | "ActionFlags": ["service_action", "report", "call_home"], |
| 852 | |
| 853 | "SRC": { |
| 854 | "Type": "11", |
| 855 | "ReasonCode": "0x76F1", |
| 856 | "Words6To9": {} |
| 857 | }, |
| 858 | |
| 859 | "Callouts": [ |
| 860 | { |
| 861 | "CalloutList": [ |
Matt Spinler | 8060019 | 2020-10-23 09:29:33 -0500 | [diff] [blame] | 862 | { |
| 863 | "Priority": "high", |
| 864 | "SymbolicFRUTrusted": "air_mover", |
| 865 | "UseInventoryLocCode": true |
| 866 | }, |
| 867 | { |
| 868 | "Priority": "low", |
| 869 | "LocCode": "P0" |
| 870 | } |
Matt Spinler | 60d1c39 | 2020-09-23 15:23:24 -0500 | [diff] [blame] | 871 | ] |
| 872 | } |
| 873 | ], |
| 874 | |
| 875 | "Documentation": { |
| 876 | "Description": "A fan is missing", |
| 877 | "Message": "A fan is missing", |
| 878 | "Notes": [ |
| 879 | "This error occurs when a fan has been missing for a ", |
Matt Spinler | 8060019 | 2020-10-23 09:29:33 -0500 | [diff] [blame] | 880 | "certain amount of time. The first callout is the ", |
| 881 | "symbolic FRU AIR_MOVR that has the trusted fan location ", |
| 882 | "code, which it gets using the passed in ", |
| 883 | "CALLOUT_INVENTORY_PATH. The second callout is the FRU ", |
| 884 | "where the controller is." |
Matt Spinler | 60d1c39 | 2020-09-23 15:23:24 -0500 | [diff] [blame] | 885 | ] |
| 886 | } |
Matt Spinler | 3fd08d6 | 2019-10-22 14:25:33 -0500 | [diff] [blame] | 887 | } |
Matt Spinler | 44792fd | 2019-09-26 15:58:58 -0500 | [diff] [blame] | 888 | ] |
| 889 | } |